Dry Eye Syndrome Clinical Trial
Official title:
The Effect of Manuka Eye Drops on Tear Film Properties
Verified date | April 2021 |
Source | The University of New South Wales |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Traditionally, Manuka honey has been used to combat against bacteria and reduce inflammation (the body's way of reacting to infection, irritation or other injury). Due to the inflammatory nature of dry eye, Manuka eye drops show promise as a treatment for dry eye disease. The aim of this research is to compare the effects of two over the counter eye drops that are used to treat dry eye conditions over a one month period.
Status | Completed |
Enrollment | 46 |
Est. completion date | October 30, 2018 |
Est. primary completion date | October 30, 2018 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility | Inclusion Criteria: - Able to read and comprehend English and give informed consent as demonstrated by signing a record of informed consent; - General population aged 18 years and over; - In good general health; - Subjectively experiencing dry eye symptoms (e.g. burning, irritation, and discomfort due to dryness of the eye or exposure to wind or sun). Participants will be selected based on a minimum OSDI score of 13 points (1). - Willing to discontinue CL wear for 1 week before first visit and continue to do so until the conclusion of the study; - Participant is willing to discontinue their use of any previous conventional dry eye treatment method commenced before the study throughout the study; - Willing to comply with the dosage and study visit schedule as directed by the investigator; - No planned changes to diet and willing not to substantially alter their usual diet for the duration of the study, including their typical intake of fish, green tea or oral supplements known to have anti-inflammatory properties; - Willingness to notify the study investigator if instructed to alter their diet by health/medical practitioner. Exclusion Criteria: - Allergy to benzoic acid preservatives; - Allergy to honey products; - Active anterior eye disease/ infection, inflammation/allergy that requires ocular medical treatment; - Eye injury or surgery in the past 6 months including chemical burns, penetrating injuries, traumatic iritis, orbital fractures, laser surgery, strabismus surgery, cataract or any other intraocular surgeries; - Soft contact lens, rigid gas permeable, orthokeratology lens wearer within one week prior to the study and during the study. - Use of any of the following medications (including steroids) up to 12 weeks prior to start of the study or during the course of the study: - Ocular medication, category S3 and above; - Any systemic or topical medications that will affect ocular physiology e.g. anti-acne medications such as Roaccutane and corticosteroid or immunosuppressant medications such as Hydrocortisone, Prednisolone and antihistamine medications such as Claritine; - Any systemic disease that may affect ocular health e.g. Graves disease, and auto-immune diseases such as ankolysing spondylitis, multiple sclerosis and systemic lupus erythematosis; - Epilepsy or history of migraines exacerbated by flashing, strobe-like lights. |
Country | Name | City | State |
---|---|---|---|
Australia | School of Optometry and Vision Science | Sydney | New South Wales |
Lead Sponsor | Collaborator |
---|---|
The University of New South Wales |
Australia,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | A Measurable Difference in Tear Lipid Layer Thickness After 4 Weeks of Daily Use | The primary endpoint is a measurable difference in tear lipid layer thickness between Optimel Manuka eye drops and Systane Ultra eye drops after 4 weeks of daily use. Tear film inferior lipid layer thickness (LLT; nm) is measured using the LipiView II (Johnson and Johnson Vision, USA). The participant's eye is positioned in front of an illumination source that is directed toward the tear film on the corneal surface. The camera records a 20-second video of the tear film interference and subsequently displays a value in interferometric colour units (ICU), where 1 ICU approximates 1nm of lipid layer thickness. | 28 days | |
Primary | A Measurable Difference in Tear Evaporation Rate After 4 Weeks of Daily Use. | A measurable difference in Tear evaporation rate between Optimel Manuka eye drops and Systane Ultra eye drops after 4 weeks of daily use. Measured using a Modified Vapometer. The Modified Vapometer is a closed chamber device which is used for measuring transepidermal water loss. Participants will be seated upright on a chair and provided with a distance fixation target. To minimize the effect of skin evaporation, petroleum jelly (Vaseline, http://www.unilever.com.au/brands-in-action/detail/Vaseline/299339/) will be applied over the upper eyelid and the surrounding areas. The VapoMeter will then be placed over the eye and a non-invasive measurement of tear evaporation will be taken within 10 s. Participants will be instructed not to blink during open eye measurement and to maintain a normal straight gaze at the fixation target. Evaporation rates with the eyes closed will also be taken, in order to account for the skin evaporation from eyelids and surrounding skin tissue. | 28 days | |
Primary | A Measurable Difference in Fluorescein Tear Break-up Time After 4 Weeks of Daily Use | A measurable difference in fluorescein tear break-up time between Optimel Manuka eye drops and Systane Ultra eye drops after 4 weeks of daily use. Fluorescein tear break-up time (TBUT; sec) (Opti-Strip-FL, Optimed, Lane Cove West, NSW, Australia) was measured viewed with a yellow Wratten filter (No. 12, Kodak) and cobalt light of the slit lamp biomicroscope. Three consecutive TBUT measurements for each eye were taken by a single masked investigator. | 28 days | |
Secondary | A Measurable Difference in Subjective Symptoms After 4 Weeks of Daily Use | A measurable difference in subjective symptoms between Optimel Manuka eye drops and Systane Ultra eye drops after 4 weeks of daily use. Subjective symptoms is measured using an visual analogue scale ranging from 0 to 100, with higher scores meaning worse outcome. Participants are asked to visually represent their symptom severity by marking a dot on a line ten centimetres in length. These are then measured using a ruler to the nearest 0.5mm and given a score from zero to 100, with zero indicative of no symptoms and 100 suggesting maximum symptom severity | 28 days |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02597803 -
Assessment of the Safety and Efficacy of RGN-259 Ophthalmic Solutions for Dry Eye Syndrome: ARISE-1
|
Phase 2/Phase 3 | |
Completed |
NCT02522312 -
A Retrospective Analysis of Restasis® Benefits in Dry Eye Contact Lens Patients
|
N/A | |
Completed |
NCT01863368 -
Clinical Evaluation of Systane® ULTRA Compared to OPTIVE® in Ocular Surface Staining
|
N/A | |
Completed |
NCT01753752 -
Evaluation of the Corneal Residence Time of Chitosan-N-acetylcysteine Eye Drops in Patients With Dry Eye Syndrome After Single and Multiple Instillation
|
Phase 2 | |
Completed |
NCT01753687 -
Correlation of Different Signs for Assessment of Dry Eye Syndrome
|
N/A | |
Completed |
NCT01212471 -
A Dose Ranging Study to Evaluate Safety and Efficacy of Bromfenac Ophthalmic Solution in Dry Eye Disease
|
Phase 3 | |
Completed |
NCT01198782 -
Evaluating Safety and Efficacy of FID 112903 Post Discontinuation of Long-term Use of RESTASIS® (Cyclosporine Ophthalmic Emulsion) 0.05%
|
Phase 4 | |
Completed |
NCT01162954 -
Phase I Study to Evaluate the Tolerability of Eye Drop DA-6034 in Healthy Volunteers
|
Phase 1 | |
Completed |
NCT00544713 -
Evaluate the Safety and Efficacy of a New Artificial Tear for Use After LASIK Surgery
|
N/A | |
Completed |
NCT00535054 -
Study to Assess the Safety and Patients' Satisfaction of Tears Again* in the Treatment of Dry Eye Symptoms
|
N/A | |
Completed |
NCT00344721 -
A Placebo Controlled Double Masked Clinical Assessment Study of Essential Fatty Acid Supplement and Its Effect on Patients With Apparent Aqueous Deficient Dry Eye Syndrome
|
N/A | |
Completed |
NCT03830359 -
Efficacy, Safety of T2769 in Dry Eye Disease
|
N/A | |
Completed |
NCT04139122 -
Safety, PK and Efficacy Study of SJP-0132 in Subjects With Dry Eye Disease
|
Phase 1/Phase 2 | |
Completed |
NCT02758327 -
Evaluation of Tear Osmolarity Over Time With Sustained Use of Thera Tears Lubricating Drops
|
Phase 4 | |
Completed |
NCT02066051 -
IPL and Meibomian Gland Expression to Treat Ocular Rosacea Ocular GVHD
|
N/A | |
Completed |
NCT01970917 -
Effect of Olixia Pure® Eye Drops on Tear Film Thickness in Healthy Subjects
|
Phase 4 | |
Completed |
NCT02092207 -
Phase 2 Study to Evaluation the Safety and Efficacy of Orally Administered KL7016 in Patients With Dry Eye Syndrome
|
Phase 2 | |
Completed |
NCT01541891 -
Efficacy and Safety of PRO-148 Ophthalmic Solution Versus SYSTANE® in the Treatment of Patients With Dry Eye Syndrome
|
Phase 2 | |
Completed |
NCT01252121 -
Residence Time Evaluation of Systane Ultra Lubricant Eye Drops vs. Hialid and Saline
|
N/A | |
Completed |
NCT00765804 -
Safety and Efficacy Study of Iontophoresis and Dexamethasone Phosphate to Treat Dry Eye
|
Phase 2 |