Clinical Trials Logo

Clinical Trial Summary

the aim of this work is to study how this technique will make nasal fiberoptic intubation easier and faster than the usual classic technique


Clinical Trial Description

Difficult intubation is one of the most significant issues anesthesiologists deal with, occasionally. Among these, mandibulofacial deformities face the biggest challenge in intubation and make an anticipated difficult airway (1), due to short length of mandible (HLM), short thyromental distance (TMD), short inter horizontal -incisors gap (IIG) and high grade modified Mallampati test (MMT) (2). There are several strategies to approach these patients and each technique has unique benefits that should be used on experience. Sitting endotracheal intubation is a useful technique for airway control, in patients with difficult airway or in patients in whom maintenance of the upright posture is beneficial (3), A difficult airway is defined as difficulty with facemask ventilation, difficulty with tracheal intubation, or both (3). According to new updates on difficult airway management, by the American Society of Anesthesiologists, there are non-invasive and invasive interventions for the management of difficult airway. Non-invasive interventions include, without being limited to: awake intubation, video-assisted laryngoscopy, intubating stylets or tube-changers, supraglottic airway (SGA) for ventilation (e.g., LMA, laryngeal tube), SGA for intubation (e.g., ILMA), rigid laryngoscopic blades of variousdesign and size, fiberoptic-guided intubation, and lighted stylets or light wands, while invasive interventions include surgical or percutaneous airway, jet ventilation and retrograde intubation (4). Attaching a nasal airway to a breathing circuit as a tool to assist or control ventilation is a very helpful trick to have in challenging airway management situations. Typically, Fiberoptic bronchoscope is passed through the more patent nostril to follow the major nasal pathway at the floor of the nose along the superior aspect of the hard palate, the lateral aspect of the nasal septum inferior to the lower turbinate to reach the nasopharynx where the operator identifies the pharyngeal structures, such as the base of the tongue and/or the epiglottis that are mostly "in-fall" precluding clear views of the larynx requiring a jaw thrust to visualize the laryngeal structures for patients planned to be intubated under general anesthesia [5,6]. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05399147
Study type Interventional
Source Ain Shams University
Contact
Status Completed
Phase N/A
Start date July 1, 2022
Completion date October 1, 2022

See also
  Status Clinical Trial Phase
Completed NCT03657927 - A Comparison of McGrath MAC Versus C-MAC Videolaryngoscopes in Morbidly Obese Patients N/A
Enrolling by invitation NCT04506346 - Risk Prediction of Difficult Tracheal Intubation in OSAHS Patient
Completed NCT02944305 - A Predictive Model for Difficult Intubation N/A
Completed NCT02476565 - Comparison of Endotracheal Intubation Over the Aintree Via the I-gel and Laryngeal Mask Airway Supreme N/A
Completed NCT02823392 - Difficult Bag Mask Ventilation and Difficult Intubation in Children
Completed NCT05347680 - A Comparison Between the Intubating Laryngeal Tube Suction and the Ambu AuraGain N/A
Completed NCT03265938 - Evaluation of Video Laryngoscopy in Patients With Head and Neck Pathology
Completed NCT05545982 - Comparison of Video Laryngoscope Using Miller or Macintosh Approach During Endotracheal Intubation N/A
Completed NCT03320278 - The Evaluation of Simplified Predictive Intubation Difficulty Score.
Completed NCT01532063 - Risk Factors of Difficult Intubation and Related Complications in Adults in Intensive Care Units: FRIDA-Rea N/A
Completed NCT03709524 - Orotracheal Intubation in Adult Patients: A Comparison of Standard Airtraq , Nasotracheal Airtraq Combined With a Stylet Inserted Endotracheal Tube and Standard Airtraq Combined Fiberoptic Intubation N/A
Recruiting NCT03902704 - Safety and Efficacy of Cleverscope. A New Medical Device for Tracheal Intubation N/A
Not yet recruiting NCT05607433 - Air Q Laryngeal Airway Versus the AmbuAura Gain as a Conduit for Endotracheal Intubation N/A
Completed NCT02814266 - Difficult Intubation and Anthropometric Measurement N/A
Active, not recruiting NCT04759287 - Effectiveness of C-MAC Video-stylet Versus Fiberoptic Bronchoscope for Awake Intubation N/A
Completed NCT03547193 - Two Neck Ultrasound Measurements as Predictors of Difficult Laryngoscopy
Completed NCT04822831 - The Effect of Semi-recumbent Position With Exercise Training on Long-term Ventilator-dependent Patients N/A
Completed NCT03165461 - Evaluation of the Use of Tracheal Intubation Through a Laryngeal Tube to Intubate Anesthetized Patients
Recruiting NCT02177240 - A Comparison of the Flex-it® to the GlideRite® Stylet for GlideScope® in Simulated Difficult Intubations. N/A
Recruiting NCT01612949 - Facial Analysis to Classify Difficult Intubation