The aim of this study is first to validate an IC measurement using analysis of two 3D acquisitions, and to appreciate the inter-observer variability of this IC measurement between a trained technician of respiratory function analysis and a trained pulmonologist.


Clinical Trial Description

3D visualization of the chest and abdomen surface in static condition is a simple and inexpensive solution to measure regional volume changes between two static respiratory volume positions. Five seconds of apnea is necessary for visualizing the thoraco-abdominal surface. If the two positions visualized correspond to the functional residual capacity (FRC) and the total lung capacity (TLC) the volume difference is inspiratory capacity (IC) which depends to the inspiratory muscles activation. This IC can be split in different thoraco-abdominal compartments and in supine position the abdominal contribution of this IC volume appreciates non-invasively diaphragmatic function. In addition asymmetry between right and left sides can appreciate unilateral diaphragmatic. The aim of this study is first to validate an IC measurement using analysis of two 3D acquisitions, and to appreciate the inter-observer variability of this IC measurement between a trained technician of respiratory function analysis and a trained pulmonologist. Accordingly, patients addressed for suspicion of diaphragmatic dysfunction, and able to maintain 5 sec of apnea in supine position will be proposed, by using the informed consent process, to participate to this study which consisted to beneficiate to a 3D trunk visualization at FRC and TLC during a spirometric IC measurement in supine position. Thoraco-abdominal volume difference between the two positions (FRC and TLC) will be calculated to obtain a 3D-IC volume. Then a Bland-Altman comparison will be done between the 3D-IC volumes measured and calculated by the two different observers (technician and pulmonologist), and the spirometric-IC volume considered as the reference. The Bland-Altman average discrepancies (the bias) and to the wide of the limits of agreement obtained will allow to select the best observer between the technician and the pulmonologist. After the validation of the 3D-IC measurement against spirometry (difference > 10%), and after having confirmed that this analysis can be performed in routine by a pulmonary function technician, the next step will be to validate that the decrease of abdominal contribution of 3D-IC is an non-invasive index of diaphragmatic dysfunction. Accordingly, a linear regression analysis will be used in this study between the abdominal contribution to 3D-IC and the other parameters issued from exams prescribed by the clinician to confirm and evaluate diaphragmatic dysfunction. These other parameters are usually the fall of CV in supine position and/or a decrease of transdiaphragmatic pressure (Pdi) measurement by estimating the difference between oesophageal pressure (Peso) (intrathoracic pressure) and gastric pressure (Pga) (intra-abdominal pressure), [Pdi=Pga-Peso]. Pdi can be obtained during maximal voluntary efforts (the most frequent being the sniff test (Sniff Pdi)) or by using non-volitional test such as magnetic stimulation of the phrenic nerves (Twitch Pdi). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05339698
Study type Observational
Source Assistance Publique - Hôpitaux de Paris
Contact Frédéric LOFASO, MD, PhD
Phone + 33 (0)1 47 10 79 41
Email f.lofaso@aphp.fr
Status Recruiting
Phase
Start date September 2, 2022
Completion date September 2024

See also
  Status Clinical Trial Phase
Completed NCT01962298 - Recovery of Diaphragmatic Function After Neuromuscular Blockade and Sugammadex Phase 3
Completed NCT01737775 - Comparative Ultrasonic Study of Post Operative Diaphragmatic Dysfunction in Abdominal and Head and Neck Surgery N/A
Completed NCT05516901 - Ultrasound Guided Erector Spinae Plane Block on Post-operative Pain and Diaphragmatic Dysfunction in Epigastric Hernia N/A