Diabetic Foot Ulcer Clinical Trial
Official title:
Multi-material, Layer, and Density Insoles for a Patient-specific Approach to Shear and Pressure Reduction in the Treatment and Prevention of Diabetes-related Foot Ulcer
In this pilot study, the first objective is to bench test a novel shear reducing insole and compare it to current standard insoles and shoes. The second objective is to study twenty-seven insensate diabetes patients with pre-ulcerative foot callus to examine for changes in spatial temporal gait including gait initiation, risk of falling, static and dynamic balance, and plantar temperature response to walking and consecutive plantar stress in both footwear conditions.
Device Description: The Dynamic Foot Orthosis (DFO) is designed with a rolling link
mechanism at the distal 3rd. It is designed to reduce sliding friction and torque at the
metatarsal heads in addition to decreasing compressive forces that is accomplished by the
conventional multi-durometer FOs. The relative sliding motion of two compliant surfaces over
each other allows some deformation horizontally and lowers frictional resistance. The DFO
addresses the friction element by accommodating the normal sliding and rolling motion at the
distal 3rd of the foot during gait. Additionally, the DFO has a silicone layer at the
metatarsal head and the remainder of the anterior section made of 2 separated orthotic
layers that slide over each other. This provides an articulating surface to provide a
relative motion between the orthotic segments while transmitting load.
Study Objectives: In this pilot study, the first objective is to bench test a novel shear
reducing insole and compare it to current standard insoles and shoes. The second objective
is to study twenty-seven insensate diabetes patients with pre-ulcerative foot callus to
examine for changes in spatial temporal gait including gait initiation, risk of falling,
static and dynamic balance, and plantar temperature response to walking and consecutive
plantar stress in both footwear conditions.
Study Design: This is an interventional study. For objective one, changes in compression
stiffness and static coefficients of friction will be measured using a force dynamometer in
the lab of Professor Albert Shih. A test platform will be built to evaluate the performance
of the shear reduction shoe sole design and characteristic of the force, in two directions
parallel (shear) and perpendicular to the ground, and the associated deformation under the
steady-state and impulse conditions.
For objective two, diabetes patients presenting to the Michigan Orthotics and Prosthetics
Center for fabrication and dispensing of diabetic shoes and innersoles will be invited to
participate. Twenty-seven insensate diabetes patients with pre-ulcerative foot callus will
be enrolled. Patients will wear body worn sensors (LegSys) to measure changes in
spatial-temporal gait and static and dynamic balance parameters prior and post usage of the
insoles. To reduce the effects of learning from naïve use of novel footwear, the testing
sequence between the experimental and standard footwear will be randomized. We will examine
increase on foot temperature over 200 steps of continuous walking using the DFO and using
standard insoles. We will also examine if the thermal changes are mediated by autonomic
neuropathy as measured by sudomotor function. The footwear testing sequence will be
randomized and an acclimatization procedure will be followed in an effort to minimize the
potential effects of cumulative plantar temperature responses to walking and footwear
conditions. We will also examine static balance by measuring center of mass with eyes open
and eyes closed condition.
Outcome Measures: For objective one, the primary endpoints will be the compression stiffness
and static coefficients of friction. For objective two, plantar foot temperature changes in
regions-of-interest in response to walking 200 steps will be measured in each footwear
condition and compared to baseline. Other outcome measures include gait analysis, including
gait initiation, gait speed, double support time, medial and lateral center of mass
displacement, and inter-cycle variability under single and dual task conditions. This will
be measured during each footwear condition. Static balance will also be measured in each
footwear condition. Using the Romberg's test, we will also assess center of mass
displacement and reciprocal hip and ankle motion under eyes open and closed conditions.
Sudomotor function will be measured by electrical sweat conductance (ESC), as expressed in
microSiemens (µS).
Safety Evaluation: All subjects who sign the informed consent form and are determined to be
eligible for treatment will be included in the analysis of safety. Collection,
classification and summary analysis of adverse events will be performed.
Duration of Participation: One visit lasting approximately 1 hour.
Duration of Study: One year
Inclusion Criteria: Patients will be included if they have diabetes and have been referred
for diabetic shoes. They will also be insensate with pre-ulcerative plantar callus or
previous plantar foot ulcer.
Exclusion Criteria: Patients will be excluded if they are unable to independently walk 100
feet, lower extremity prosthesis user, have active cellulitis, foot ulcer, or Charcot foot.
;
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Crossover Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Prevention
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04497805 -
Clinical Study of ALLO-ASC-SHEET in Subjects With Diabetic Wagner Grade II Foot Ulcers
|
Phase 2 | |
Withdrawn |
NCT03675269 -
Adjunctive Hyperbaric Oxygen Therapy (HBOT) for Lower Extermity Diabetic Ulcer:
|
N/A | |
Completed |
NCT04624516 -
Effect of Self-foot Exercise on the Incidence of Plantar Foot Diabetic Ulcer Recurrence
|
N/A | |
Not yet recruiting |
NCT06439667 -
VIRTUALLY SUPERVISED TELE-EXERCISE PLATFORM FOR ACCELERATING PLANTAR WOUND HEALING
|
||
Recruiting |
NCT05608187 -
Evaluating Safety and Biological Effect on Wound Healing of ILP100-Topical in Subjects With Diabetic Foot Ulcers
|
Phase 2 | |
Not yet recruiting |
NCT06437028 -
Evaluating the Efficacy of Perinatal Membrane Allografts for the Treatment of Diabetic Foot Ulcers.
|
N/A | |
Not yet recruiting |
NCT06278935 -
Lifestyle Tailored Offloading for Diabetic Foot Ulcers
|
N/A | |
Withdrawn |
NCT05024656 -
AmnioExcel® Plus vs SOC in the Management of Diabetic Foot Ulcers
|
N/A | |
Terminated |
NCT02202668 -
Transcutaneous Raman Spectroscope (TRS) Analyses of Diabetic Foot Ulcers
|
N/A | |
Terminated |
NCT01966380 -
Proof of Concept (Design Validation) in Patient With Hard to Heal Wounds Such as Pressure Ulcer, Diabetic Foot Ulcer and Leg Ulcer, Leia
|
Phase 2 | |
Completed |
NCT01951768 -
Efficacy and Safety of Garamycin® Sponge in Diabetic Patients With a Moderate or Severe Foot Ulcer Infection
|
Phase 4 | |
Completed |
NCT01657474 -
Comparative Study of Two Application Regimens of Amniotic Membrane Wound Graft In the Management of Diabetic Foot Ulcers
|
N/A | |
Active, not recruiting |
NCT00389636 -
TheraGauzeā¢ Alone and Regranex®Gel 0.01% Plus TheraGauzeā¢ in the Treatment of Wagner Stage I Diabetic Foot Ulcers
|
N/A | |
Completed |
NCT01181440 -
Dermagraft(R) for the Treatment of Patients With Diabetic Foot Ulcers
|
Phase 3 | |
Enrolling by invitation |
NCT05888259 -
Plantar Pressure Distribution in Diabetic Foot Ulcer
|
N/A | |
Completed |
NCT04054804 -
Digital Foot Check by Using the D-Foot, a New Software
|
||
Not yet recruiting |
NCT05877378 -
Efficacy of PICO Single-use System in Chronic Ulcers
|
N/A | |
Recruiting |
NCT06037369 -
The Short Message-based Customized Standardized
|
N/A | |
Completed |
NCT03312595 -
Clinical Outcomes After Treatment With RestrataTM Wound Matrix in Diabetic Foot Ulcers (DFU)
|
N/A | |
Recruiting |
NCT04564443 -
A Unique Micro Water Jet Technology Device Versus Standard Debridement in the Treatment of Diabetic Foot
|
N/A |