Clinical Trials Logo

Clinical Trial Summary

Tooth loss is a major dental problem worldwide. A recent study in Singapore found that approximately one third of adults aged over 65 are living without any natural teeth. Prevalence of loss of some teeth, or partial edentulism, in this population is estimated to be even higher. Tooth loss has a series of deleterious consequences for oral and general health. The high prevalence of tooth loss has resulted in great needs and demands of prosthetic replacements, posing challenges to the public dental care system in Singapore. Removable dentures are the most widely and commonly used device to replace missing teeth and restore oral functions. The removable denture possesses a metal framework that connects other components of the denture, to ensure rigidity and stability while in function. However, the current method of fabricating denture frameworks is a complex, error-prone, time-consuming, and expensive process. Due to the inherent inaccuracies in the materials and technique, fit of the framework is compromised and undesirable to meet patients' satisfaction. With the new development of computer aided design and 3D printing metal techniques, it is now possible to apply digital design and manufacturing for the fabrication of dentures. This proposal aims to compare the precision and fit, and patient satisfaction, of 3D printed and conventional casted removable denture frameworks in preclinical and clinical settings.


Clinical Trial Description

Tooth loss or edentulism is a major dental problem worldwide, particularly among the senior population. A recent study in Singapore found that approximately one third of adults aged over 60 are living with complete edentulism. Prevalence of partial edentulism in this population is estimated to be even higher. The high prevalence of tooth loss has resulted in great needs and demands of prosthetic replacements, posing challenges to the public dental care system in Singapore. Removable denture prosthesis is the most commonly used device to replace missing teeth and restore oral functions. The removable denture prosthesis possesses a metal framework that connects the clasps, retainers, base and acrylic teeth, to ensure rigidity and stability while in function. However, the current way of fabricating denture frameworks using casting method is a time consuming, complex, error-prone, and expensive process. Due to the inherent inaccuracies in the materials and technique, the fit of the framework is compromised and undesirable to meet patients' satisfaction. With recent developments in computer aided design and additive manufacturing, commonly known as 3D printing or rapid prototyping, the techniques allow for printing of complex metal structures of high strength, stiffness and chemical resistance. This proposal aims to compare the precision and fit, and patient's satisfaction, of 3D printed denture frameworks and eventually translate this to a more efficient denture fabricating process. The removable denture prosthesis is the most commonly used device to replace missing teeth and restore oral functions in patients with partial and complete edentulism. The fabrication of framework using conventional methods is time consuming and inaccurate. Thus the ultimate goal of this study is to enhance the workflow efficiency, improve the fabrication precision of the device, reduce treatment cost and time, and promote oral function and overall quality of life of patients. At the same time, the research methods developed from this study is a platform for the study of new dental devices, with potential applications for new digital dental practices. Thus, if successful, the deliverables from this research will both advance dental research, and extend applicable knowledge to the clinic. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04304222
Study type Interventional
Source National Dental Centre, Singapore
Contact
Status Completed
Phase N/A
Start date March 26, 2019
Completion date October 5, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT04045574 - DAMP1: The 1T1T Concept Versus Conventional Implant Loading Protocol N/A
Recruiting NCT05296291 - RCT: Titanium vs FCZ vs Zirconia Framework N/A
Active, not recruiting NCT05752539 - Clinical Evaluation of Implants Restored With Advanced Lithium Disilicate Screw-retained Crowns
Active, not recruiting NCT05599269 - Retrospective Clinical Evaluation of Nano-hybrid-composite Denture Teeth N/A
Not yet recruiting NCT04151316 - Study of Periodontal Tissues in Fixed Prostheses on Natural Teeth N/A
Completed NCT03720236 - Peri-implant Tissues in BLX® Implants N/A
Recruiting NCT05958043 - Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations N/A
Completed NCT03796494 - Peri-implant Tissues on Aesthetic Slim Abutment Galimplant (PSG) N/A
Recruiting NCT02898311 - One-Tooth One-Time (1T1T) A Straightforward Approach to Replace Missing Teeth in the Posterior Region: a Case Series N/A
Completed NCT01449903 - Survival of Different Core Build-up Materials
Completed NCT04870658 - Patient's Perception of Complications in Implantology.
Completed NCT05842655 - Digital Technique to Analyze the Wear of Implants and Natural Tooth as Antagonist. N/A
Completed NCT03640910 - Attachment Systems for Implant Overdenture N/A
Completed NCT04272112 - Clinical Performance of All-ceramic Posterior Crowns. A Randomized, Prospective Clinical. N/A
Active, not recruiting NCT01729858 - Survival of Implant-Supported All-Ceramic Prostheses
Recruiting NCT05818436 - Immediate Dental Prosthesis Functionalization Protocol in People Over 70 Years of Age N/A