Clinical Trials Logo

Clinical Trial Summary

The goal of this randomized controlled clinical trial is to compare implant stability between hybrid implants and fully rough implants in partially edentulous patients. The main question it aims to answer is: are hybrid implants able to achieve a sufficient level of secondary stability in comparison to fully etched implants? Participants will receive dental implants and the secondary stability will be measured using resonance frequency analysis (RFA) at the 2-month post-implant placement mark. Implants that do not attain adequate secondary stability will undergo re-evaluation at monthly intervals up to 6 months. Researchers will compare the test group (hybrid implants) or the control group (fully rough implants) to see if they present a comparable secondary stability.


Clinical Trial Description

This is a randomized triple-blinded, parallel-arm (1:1) controlled clinical trial with 6 months follow-up. Implants will be placed in 16 private practices. 128 patients will be randomly allocated to the test (hybrid implants)(64) and control (fully etched implants)(64) groups following stratified randomization in such a way that an equal number of patients in the test and in the control group will be enrolled in each study centre. The following individuals will be blinded as follows: 1) patients involved in the study will not be aware of the implants that are receiving; 2) surgeons: after the screening examination clinicians will choose the implant dimension but they will not be aware of the surface characteristic of the implant they are going to place until the implant socket is prepared; 3) the data collector/outcome assessor: of the implant stability will not be aware of the group allocation; 4) the statistician will not be aware of the group allocation. Treatment allocation will be concealed by using opaque sealed boxes and opened immediately before the implant placement (after implant socket preparation). At least 2 hours before the surgery all patients will be given antibiotic prophylaxis of 2g of amoxicillin (600mg of clindamycin for patients that allergic to penicillin). All implants (more than one implant per patient might be included) will be placed by 16 experienced surgeons in their respective clinic following according to the instruction provided by the manufacturer. The apicocoronal position of the implants will be equicrestal (i.e. the most coronal part of the machined collar is at the level of the alveolar ridge) or subcrestal (≤1 mm). In the test group and control group hybrid implants and fully etched implants (Volution, IRES®, Switzerland) will be placed. After surgery, in order to control discomfort and swelling, 600 mg ibuprofen every 8 hours if needed will be given. All subjects will be prescribed 0.12% chlorhexidine mouth rinse twice daily for 7 days. Immediately after the implant placement (Tpl) and at two months (T2) the implant stability will be measured using magnetic RFA (OsstellTM Mentor AB, Gothenburg, Sweden) by a trained clinician not involved in the study. The transducer will be screwed manually and RFA measurement were made both in the mesio-distal (MD) and bucco-lingual (BL) direction by keeping the device perpendicular at a distance between 2-4 mm and at least 3mm far away from the soft tissues. The peak insertion torque will be also registered. All implants will be submerged. Implants with ISQ values < 60 at the revaluation (T2) will undergo further measurements after 1 month till the 6th month after their placement. If at any timepoint (T2, T3, T4, T5, T6) the implant reaches a sufficient (stability ≥60) it will be considered stable till the end of the study, hence, no further ISQ assessment will be carried out and the prosthesis will be delivered (TL). Continuous variables will be expressed as mean and standard deviation, whereas the absolute and relative frequency will be calculated for categorical variables. Regarding continuous variables, differences between groups will be tested by parametric or non-parametric test after testing the normal distribution of the data (Shapiro-Wilk test). For categorical variables chi-squared test (or Fisher test) will be adopted. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06100120
Study type Interventional
Source University of Milan
Contact Giulio Rasperini, DDS
Phone +393358130194
Email giulio.rasperini@unimi.it
Status Recruiting
Phase N/A
Start date November 15, 2023
Completion date January 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05466006 - Peri-implant Soft Tissue Volume Changes at Small Buccal Dehiscences N/A
Withdrawn NCT00313989 - Evaluation of Osseo-integration After Placement of Dental Implants With Patients Receiving Radiotherapy for Buccopharyngeal Oncology N/A
Completed NCT05081050 - Short Implants Supporting Single Crowns in the Posterior Region
Completed NCT04707677 - Comparative Aesthetic Analysis Between Titanium and Ceramic Implants N/A
Recruiting NCT05989061 - PEEK Versus Titanium Customized Healing Abutments N/A
Recruiting NCT05722041 - Soft Tissue Volume Changes in Posterior Socket Sealing Abutment.
Completed NCT05512845 - The Double Factor Technique: a Computer-guided Implant Surgery Technique for Fully Edentulous Patients
Recruiting NCT03837158 - Titanium Zirconium (TiZr) Mini Implants N/A
Completed NCT01944267 - Procedures for Improving the Mucosa Around Implants N/A
Completed NCT00971516 - Healing Profile of Titanium Dental Implants Placed in Patients With Diabetes N/A
Completed NCT04305080 - Effect of Anodic Oxidation of Implant Abutment Collar on the Peri-implant Soft Tissue Health N/A
Completed NCT06191510 - Xenogenic Bone Intentionally Left Exposed
Completed NCT04459494 - In the Treatment of Implants With Different Methods; Early Bone Loss and Patient Satisfaction N/A
Recruiting NCT05644470 - Association of Implant Position and Crown Contour With Tissue Health
Completed NCT05101954 - Platelet Rich Fibrin and Concentrated Growth Factors on Osseointegration of Immediate Implants N/A
Recruiting NCT05748379 - Atraumatic Zirconia Abutment Versus Customized Composite Healing Abutment in Maxilla or Mandible. N/A
Recruiting NCT05627037 - Marginal Bone Level Around Titanium Implants Produced by Additive Manufacture N/A
Enrolling by invitation NCT06187805 - Retrospective Case Series - OSSIX Volumax Collagen Xenograft Scaffolding
Recruiting NCT06155799 - Accuracy of Dynamic Navigation System on Zygomatic Implant Placement N/A
Recruiting NCT04960904 - Study Evaluating the Performance and Safety in the Medium and Long Term of Global D Implant-prosthetic Systems