Clinical Trials Logo

Clinical Trial Summary

This randomised clinical study aims to evaluate different surfaced implants (alkali-modified surfaced implants or sand-blasted surfaced implants) stability with resonance frequency analysis(RFA).


Clinical Trial Description

This is randomised controlled double blind study. Fourteen patients (8 women and 6 men;age 43.7 ± 8.56 years) who were attending the Oral and Maxillofacial Surgery Department and scheduled for implant placement surgery were included in this study. Dental implants were placed using one-stage protocol. After adminstration of local anesthesia (Ultracain DS; Aventis Pharmaceuticals, Istanbul, Turkey ), an incision was made on the alveolar ridge. A total of 50 implants (Impladent implants from the Lasak) were placed in the not site assignement mandibular premolar/molar sites according to the manufacturer's instructions. To prevent bias which implant to the right or left to make the decision investigators decided by envelope. The person making the measurement does not know which surface implant is made to the patient. An equal number of implants were applied simultaneously with different surfaces. The patient does not know where the implant is placed. All used implants were 3.7 width, 10mm. height and same design for standardization this study. Investigators obtained good primarly stability and placed a healing cap for 45 implants . 3 sandblasted and acid-and alkali-treated surface straight (bioactive)implants and 2 sandblasted surface straight implants were excluded in this study for bad primary stability. Investigators used to measure implant stability with Osstell ISQ ( Integration diagnostic AB, Savedalen, Sweden) for each implant at the time of surgery before flap closure, 2. week,6. week and 12. week postoperatively.This device was used in both buccolingual and mesiodistal direction. The Smartpegs (Integration Diagnostics AB, Göteborg, Sweden) were compressed and the measurements were performed by the same surgeon for standardization of the stability measurements. The measurements were taken twice in the buccolingual direction and twice in the mesiodistal direction. The arithmetic mean of the 2 measurements from each direction was regarded as the representative ISQ of that implant. In addition, each implant was clinically evaluated at all visits for mobility, pain, and signs of infection. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03915509
Study type Interventional
Source Adnan Menderes University
Contact
Status Completed
Phase N/A
Start date April 2011
Completion date March 2012

See also
  Status Clinical Trial Phase
Recruiting NCT04945629 - Plasma Rich in Growth Factors in the Preservation of the Alveolar Ridge After Simple Molar Tooth Extractions. Phase 3
Recruiting NCT05758337 - Vibropneumostimulation in the Rehabilitation After Dental Implantation N/A
Recruiting NCT05741749 - Immediate Implant Placement in the Posterior Region Combining Sealing Socket Abutment and Peri-implant Socket Filling. N/A
Recruiting NCT04093583 - Randomized Clinical Trial, Conventional Treatment-controlled, Studying the Efficacy of Plasma Rich in Growth Factor (PRGF®) in Alveolar Ridge Preservation After Simple Exodontia in the Anterior Region of Maxilla. Phase 3
Not yet recruiting NCT03321162 - Accuracy of Guided Implant Placement Using Double Versus Triple Scan Protocol in Completely Edentulous Patients N/A
Completed NCT00066014 - Clinical Investigation of Mandibular Implant Overdenture Phase 2
Completed NCT05843526 - Influence of Implant Component Materials on Peri-implant Soft Tissue Horst Response. N/A
Completed NCT06323993 - The Effect of Different Window-preparation Approaches on the Clinical Outcomes of Lateral Sinus Floor Elevation
Not yet recruiting NCT06044246 - Influence of Human Platelet Derivatives on Dental Implant N/A
Not yet recruiting NCT03164759 - Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study N/A
Completed NCT04950491 - Patient-reported Outcome Measures Comparing Static Computer-aided Implant Surgery and Conventional Implant Surgery N/A
Recruiting NCT05938868 - Low Intensity Pulsed Ultrasound Versus Low Level Laser Therapy Post Dental Implant N/A
Not yet recruiting NCT00519571 - Evaluation of the Safety and Efficacy of Using ImplantLock Device - Dental Implant Accessory N/A
Recruiting NCT05817526 - BMAC Loaded Collagen Jumping the Gap Around Immediate Implants N/A
Completed NCT03222219 - Implant Insertion Torque and Primary Stability
Completed NCT04346706 - Immediate Implant Placement in Fresh Extraction Sockets and Delayed Implants in Healed Sockets. N/A
Recruiting NCT05105113 - Evaluation of Survival and Success Rates of Zirzonia Dental Implants N/A
Recruiting NCT05983718 - A Study of Surgical Guide Assisted Dental Implantation in Bangladesh N/A
Withdrawn NCT01154868 - Clinical and Histological Evaluation of Healos® for Alveolar Ridge Augmentation Phase 4
Completed NCT06176287 - Assessment of Pain Associated With Insertion Torque and Correlation of Primary Implant Stability Measurement Methods N/A