Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05587803
Other study ID # 22056PSIWAV
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date May 9, 2022
Est. completion date June 1, 2023

Study information

Verified date May 2023
Source Universitair Ziekenhuis Brussel
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

In the intensive care unit of the Free University hospital of Brussels, sedated patients are standardly monitored with the Masimo SEDline device to see how deeply a patient is asleep. During this study we want to attach 1 extra device to 30 sedated patients, lying in the intensive care unit. This device, called the NeuroSENSE brain monitor from Neurowave systems, uses a different scale to indicate the ideal depth of sedation. In total, both devices will be hung on a patient for 2 times 35 minutes. At minute 33, a RASS score will be determined in each patient. This score will be determined by talking to the patient or administering a pain stimulus. Based on the reaction of the patient an estimation can be made how deeply a patient is sleeping. Our goal is to find out which device correlates best with the effective clinical state of the patient.


Description:

Adequate sedation level is important for patient comfort and safety. As under- and oversedation are common several devices are used that measure the Depth of Anesthesia (DoA). Each device uses its proprietary algorithm to calculate a depth of anesthesia index and each index has its own optimal range. The optimal range for the NeuroSense monitor (NeuroWave Systems inc., Cleveland, OH, USA) is between 40 and 60, while the optimal range for the SEDline monitor (Masimo Corporation; Irvine, CA, USA) is between 25 and 50. When the device indicates a value within these limits, the patient is optimally anesthetized for a surgical procedure. In this study, 30 patients will be monitored simultaneously by both the Neurowave and SedLine devices. The study will determine which device is the most accurate and therefore the most ideal for use in the ICU.


Recruitment information / eligibility

Status Completed
Enrollment 30
Est. completion date June 1, 2023
Est. primary completion date June 1, 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Sedated patients hospitalized in ICU of the University Hospital of Brussels - Patients who are monitored with the SEDline/Masimo monitor - Patients who receive Remifentanil at a maximum concentration of 0,2 µg/kg/min and propofol with a concentration between 0,5-4,0 mg/kg/h - Age above 18 years Exclusion Criteria: - Patients with facial trauma - Pregnant patients - Patients who received muscle re-laxants - Patients in prone position - Lack of informed consent from the family - Patients who are hemodynamically unstable - Patients with neurotrauma or every other neurologic disorder - Patients post neurosurgery

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Neurowave and Sedline indices in view
3 additional electrodes are attached on the patients forehead. After electrode placement, the indices of both the SEDLINE device and the NEUROWAVE device are noted every 5 seconds for 1 minute

Locations

Country Name City State
Belgium UZ Brussel Brussels

Sponsors (1)

Lead Sponsor Collaborator
Universitair Ziekenhuis Brussel

Country where clinical trial is conducted

Belgium, 

Outcome

Type Measure Description Time frame Safety issue
Primary Comparison of the depth of sedation indices per assigned RASS score using the prediction probability The main objective of the study is to compare the DoA indices of the NeuroSense/NeuroWave monitor and the SEDline/Masimo monitor in sedated patients in ICU. Both values are then correlated with the patient's clinical sedation level by assigning a RASS score to the patient each time. The RASS score stands for Richmond Agitation Sedation Scale and ranges from -5 to +4. A score of -5 stands for a patient who is unresponsive to any stimuli whereas a score of +4 means a highly combative patient. To determine which device correlates best with the clinic, predictive probability will be used. The prediction probability is a value between 0 and 1. A score of 1 corresponds to a correct classification of the DoA in each case. A value of 0 corresponds to a discordance between the clinic and the index value. The device whose predictive probability is closest to 1 correlates best with the clinic and will likely be the best device to use. 33 minutes
See also
  Status Clinical Trial Phase
Terminated NCT03781817 - Intranasal Versus Intravenous Ketamine for Procedural Sedation in Children With Non-operative Fractures Phase 4
Recruiting NCT05539521 - Efficacy and Safety of Remimazolam Besylate Versus Propofol for Sedation in Critically Ill Patients With Deep Sedation Phase 2
Completed NCT01170156 - Fluid Leakage Past Tracheal Tube Cuff : Effect of Suctioning Manoeuvre N/A
Terminated NCT02903407 - Pain, Agitation and Delirium (PAD) Protocol in the Duke CICU Phase 4
Completed NCT04695509 - Sedation and Neuromediators Concentration N/A
Not yet recruiting NCT03687424 - Can High-flow Nasal Oxygenation Improve Oxygen Saturation During Analgo-sedation in Obese Adults? N/A
Not yet recruiting NCT03687385 - The Effect of High-flow Nasal Oxygenation to the Saturation During Analgo-sedation in Different ASA Risk Class Patients N/A
Completed NCT02302391 - Pharmacokinetic Analysis of Midazolam and Fentanyl in Pediatric Patients With Long-term Analgosedation
Recruiting NCT03893877 - Comparison of Oxygenation Methods in Sedation N/A
Completed NCT00639548 - ERPS, BIS and Entropy for Neuromonitoring in ICU Patients N/A
Terminated NCT04168294 - The Influence of Sedation for Endoscopy on Cognitive Function
Withdrawn NCT04026451 - Spectral Edge Frequency From Spectral EEG Analysis to Guide Deep Sedation in the Critical Care Setting (Pilot) N/A
Completed NCT05163704 - Dexmedetomidine Sedation in Children Before MRI Examinations N/A
Completed NCT04141267 - Inhaled Sedation Using the Anesthetic-conserving Device ( ANACONDA) in Prehospital Emergency Medecine.
Active, not recruiting NCT02909010 - Bispectral Index Monitoring To Guide Sedation In The Critical Care Setting N/A
Completed NCT03652324 - What Should be the Anesthesia Method in Endobronchial Coil Treatment N/A
Completed NCT00717574 - Addition of Nitrous Oxide and Its Effects on Depth of Anesthesia N/A
Completed NCT00641563 - Effects of Two Different Sedation Regimes on Auditory Evoked Potentials and Electroencephalogram (EEG) N/A
Not yet recruiting NCT06436638 - Comparison of Nasal Continuous Positive Airway Pressure (CPAP) Mask and Nasal Airway in Molar Tooth Extraction Under Deep Sedation
Completed NCT05674201 - Effects Of Propofol-Dexmedetomıdıne And Propofol- Remıfentanıl In Hysteroscopıc Operations.