Critically Ill Clinical Trial
Official title:
Comparative In-patient, Non-intervention Study of the Remote Physiological Monitoring System (RPM™), a Non-invasive, Remote, Ambulatory Vital Signs Monitoring Device, Versus Standard Physiological Monitoring Devices by Simultaneous Monitoring of Heart Rate, ECG, SpO2, Blood Pressure, Body Temperature, and Respiration Rate in a 24 hr Monitoring Period (BRYTECH #BRY-C-01-06-RPM)
The Remote Physiological Monitoring System (RPM™) is a wireless technology for physiological
monitoring. The RPM™ is designed to capture, transmit and remotely monitor the vital signs
of a patient or group of patients. The RPM™ allows the patient to carry an unobtrusive unit
and sensor array, which is able to store and/or forward its data via existing communication
networks. This data is archivable and can be made available to a monitoring station or
stations. This approach obviates the need to provide new and expensive infrastructure to
support the system since it is designed to 'piggy-back' on the existing network.
A major clinical advantage of the RPM™ and the principal reason why it may offer a benefit
to patients, is that it provides continuous remote monitoring of vital signs, in contrast to
the current situation for ward patients, where there is intermittent vital signs monitoring.
This is a major advantage for patients and hospital staff, since there is increasing
evidence that demonstrate early recognition and treatment of clinical events, e.g., shock,
can save lives; the concurrent cost and labour saving is a further obvious benefit.
The RPM™ uses wireless technology to overcome the portability problems associated with
conventional patient monitoring systems. The RPM™ consists of the following system
components:
1. Physiological Monitoring Unit (PMU)
2. Data Aggregation Server (DAS)
3. Clinical Monitoring Position (CMP) To validate the RPM™ device for regulatory approval,
BRYTECH will evaluate the RPM™ in a clinical setting, thereby ensuring that the system
is trustworthy and acceptable to health professionals as a monitoring system in
patients. The study proposes to evaluate the accuracy and reliability of the RPM™
compared to monitors commonly used in the medical practice under the standard
conditions of medical practice The study also proposes to evaluate notification and
alarm systems, the communications interface and non-interference with existing systems,
devices, networks and procedures as well as the incremental nursing workload associated
with the integration of the RPM™ in a clinical environment. The RPM™ and reference
physiological monitoring devices will be compared for physiological monitoring
capabilities in 40 patients.
BRYTECH STUDY SUMMARY
The Remote Physiological Monitoring System (RPM™) is a wireless technology for physiological
monitoring. The RPM™ is designed to capture, transmit and remotely monitor the vital signs
of a patient or group of patients. The RPM™ allows the patient to carry an unobtrusive unit
and sensor array, which is able to store and/or forward its data via existing communication
networks. This data is archivable and can be made available to a monitoring station or
stations. This approach obviates the need to provide new and expensive infrastructure to
support the system since it is designed to 'piggy-back' on the existing network.
A major clinical advantage of the RPM™ and the principal reason why it may offer a benefit
to patients, is that it provides continuous remote monitoring of vital signs, in contrast to
the current situation for ward patients, where there is intermittent vital signs monitoring.
This is a major advantage for patients and hospital staff, since there is increasing
evidence that demonstrate early recognition and treatment of clinical events, e.g., shock,
can save lives; the concurrent cost and labour saving is a further obvious benefit.
The RPM™ uses wireless technology to overcome the portability problems associated with
conventional patient monitoring systems. The RPM™ uses off the shelf computer technology
such as standard displays, as well as secure, wireless, 802.11 networking protocols and
consists of the following system components:
1. Physiological Monitoring Unit (PMU)
2. Data Aggregation Server (DAS)
3. Clinical Monitoring Position (CMP)
To validate the RPM™ device for regulatory approval, BRYTECH will evaluate the RPM™ in a
clinical setting, thereby ensuring that the system is trustworthy and acceptable to health
professionals as a monitoring system in patients. The study proposes to evaluate the
accuracy and reliability of the RPM™ compared to monitors commonly used in the medical
practice under the standard conditions of medical practice; this study will therefore be a
non-intervention study. The study also proposes to evaluate notification and alarm systems,
the communications interface and non-interference with existing systems, devices, networks
and procedures as well as the incremental nursing workload associated with the integration
of the RPM™ in a clinical environment. The RPM™ and reference physiological monitoring
devices will be compared for physiological monitoring capabilities in 40 patients from the
following four (4) cohorts:
1. Cohort 1 (Exercise): patients who are scheduled to undergo a minimum of 20 minutes of
exercise testing.
2. Cohort 2 (ICU): patients admitted to the Intensive Care Unit (ICU)
3. Cohort 3 (Post-op): patients in Post-Operative care
4. Cohort 4 (ER): patients admitted to the Emergency Room (e.g., high risk medical
admissions) These cohorts are considered representative of a broad spectrum of the
general patient population. Patients participating in the study will be assigned to one
of these 4 cohorts, with a minimum of 10 patients assigned to Cohort 1 (Exercise) and a
minimum of 5 patients in each of the other cohorts.
For the study, the RPM™ and reference monitoring devices will be time-stamped such that zero
time will be readily evaluable and patients will be fitted with all necessary sensors for
collection of vital signs, namely heart rate (HR), electrocardiogram (ECG), blood oxygen
saturation levels (SpO2), non-invasive blood pressure (NIBP), body temperature (BT) and
respiration rate (RR).
For Cohort 1 (Exercise) patients, comparative monitoring of vital signs will be done during
exercise testing for a minimum of 20 minutes with additional monitoring performed pre- and
post-exercise. There will be a minimum of 10 patients in this cohort. For patients in
Cohorts 2, 3 and 4, comparative monitoring of vital signs will be performed during the
period (24 - 72 hours) required to collect 12 Vital Sign Assessment Cycles (VSAC - defined
in Section 5.2.2) per subject, with a minimum of 5 patients in each cohort and a total of 30
patients. The four cohorts of patients have been chosen to allow comparison of vital signs
from the RPM™ and standard nursing measurement techniques over a broad range of physiologic
data (e.g. rest and exercise) and patient populations (e.g. stable and critically ill).The
primary objective for the study is to determine substantial equivalence of the RPM™ and the
reference devices or standard practice measurements by comparing the agreement (accuracy)
between paired output results for individual vital signs and the reliability of data
collection over a 24 hour monitoring period. Timepoint matched paired data for all available
timepoints will be collected from the RPM™ and the reference devices, excluding ambulatory
data, for heart rate, ECG, SpO2, blood pressure, body temperature and respiration rate.
Accuracy will be determined by assessing whether the paired values show significant
agreement. Reliability will be determined by a comparison of cumulative totals for lost data
points and error rates.
The study will be conducted according to Good Clinical Practice (GCP) guidelines with all
patients required to sign an Informed Consent Form (ICF). This is a non-intervention study
and patients tested will be subjected to use of the RPM™ as the only experimental procedure
during the trial. Importantly, patients will not be exposed to any significant risks as a
result of participating in this study.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05539521 -
Efficacy and Safety of Remimazolam Besylate Versus Propofol for Sedation in Critically Ill Patients With Deep Sedation
|
Phase 2 | |
Recruiting |
NCT04776486 -
Iohexol Clearance in Critically Ill Patients With Augmented Renal Creatinine Clearance
|
N/A | |
Completed |
NCT05766319 -
The ICU-recover Box, Using Smart Technology for Monitoring Health Status After ICU Admission
|
N/A | |
Recruiting |
NCT03231540 -
The PREServation of MUScle Function in Critically Ill Patients (PRESMUS)
|
N/A | |
Completed |
NCT02286869 -
Cardioventilatory Coupling in Critically Ill Patients
|
N/A | |
Completed |
NCT01434823 -
24 Hour Intensivist Coverage in the Medical Intensive Care Unit
|
N/A | |
Active, not recruiting |
NCT01142570 -
Effect of Enteral Nutrition Enriched in Protein and Based on Indirect Calorimetry Measurement in Chronically Critically Ill Patients
|
N/A | |
Completed |
NCT01167595 -
Enhanced Protein-Energy Provision Via the Enteral Route in Critically Ill Patients
|
N/A | |
Not yet recruiting |
NCT00916591 -
Prokinetic Drugs and Enteral Nutrition
|
N/A | |
Completed |
NCT01293708 -
Realities, Expectations and Attitudes to Life Support Technologies in Intensive Care for Octogenarians:
|
||
Recruiting |
NCT00654797 -
Improving Blood Glucose Control With a Computerized Decision Support Tool: Phase 2
|
Phase 2 | |
Withdrawn |
NCT00178321 -
Improving Sleep in the Pediatric Intensive Care Unit
|
N/A | |
Completed |
NCT01168128 -
PERFormance Enhancement of the Canadian Nutrition Guidelines by a Tailored Implementation Strategy: The PERFECTIS Study
|
N/A | |
Completed |
NCT02447692 -
Proportional Assist Ventilation for Minimizing the Duration of Mechanical Ventilation: The PROMIZING Study
|
N/A | |
Recruiting |
NCT04582760 -
Early Mobilization in Ventilated sEpsis & Acute Respiratory Failure Study
|
N/A | |
Not yet recruiting |
NCT05961631 -
Bio-electrical Impedance Analysis Derived Parameters for Evaluating Fluid Accumulation
|
||
Completed |
NCT03276650 -
Admission of Adult-onset Still Disease Patients in the ICU
|
||
Completed |
NCT03922113 -
Muscle Function After Intensive Care
|
||
Recruiting |
NCT05055830 -
Opportunistic PK/PD Trial in Critically Ill Children (OPTIC)
|
||
Recruiting |
NCT06027008 -
Mechanical Insufflation-Exsufflation (Cough Assist) in Critically Ill Adults
|
N/A |