Clinical Trials Logo

Clinical Trial Summary

Currently in the field of critical care, altered intestinal blood flow in critically ill patients has been a hot research topic in recent years. However, because the gastrointestinal tract is in the abdominal cavity and the clinic lacks perfusion direct monitoring means, at present, gastrointestinal function indicators are mostly used to guide the clinic, and the treatment is often blind and lagging. Gastrointestinal perfusion Research on gastrointestinal perfusion is mostly confined to abdominal perfusion pressure (mean arterial pressure - intra-abdominal pressure). However, according to the "Darcy law" in blood flow mechanics, Q=MAP/SVR, which means pressure≠flow. The investigators may not be able to ensure adequate blood flow to the digestive organs by relying on intra-abdominal perfusion pressure alone. Direct organ flow monitoring is a more accurate means of organization. The superior mesenteric artery (SMA) supplies all of the intestinal tract (small bowel, part of the colon) and is a long vessel that can to reflect the perfusion status of the distal overall bowel. Color Doppler ultrasonography is used to evaluate intestinal vessels such as the SMA in healthy and outpatient patients. The use of color Doppler ultrasonography to assess blood flow in intestinal vessels such as the SMA in healthy and outpatient patients has been in use since the 1980s. The investigators' team showed that the resistance index of the SMA in postoperative cardiac surgery patients correlated with lactate values and lactate clearance [Front Med (Lausanne), 2021.8:p.762376.], suggesting that gastrointestinal perfusion as reflected by SMA blood flow is important for systemic resuscitation, and that Doppler indices of SMA have the potential value of reflecting intestinal hypoperfusion. The Doppler index of SMA has the potential value of reflecting intestinal hypoperfusion. Intestinal venous blood enters the portal vein and then the liver before returning to the right heart via the inferior vena cava. Right heart dysfuction, right atrial hypertension, and abdominal hypertension can cause obstruction of portal venous return, which can lead to edema and dysfunction of the bowel. This can lead to edema of the intestinal tract and dysfunction. Therefore, monitoring the venous return status of portal vein, hepatic vein and inferior vena cava is also important for the perfusion of the intestine. Therefore, monitoring the status of venous return in the portal vein, hepatic vein, inferior vena cava, etc. is also important for intestinal perfusion. Doppler ultrasound technology has been widely used in the field of cardiac critical care and craniocerebral critical care, but it is still in the exploratory stage in the field of critical care digestion, and this study is an innovative and exploratory one.


Clinical Trial Description

Research Methods (1) Doppler ultrasound technique for intestinal blood flow assessment:An ultrasound system (X-Porte Ultrasound System, FUJIFILM SONOSITE, INC., USA) consisting of a 2-5 MHz C60xp probe was performed. Blood flow parameters were measured by two ICU physicians and the mean values were recorded. Both ICU physicians had more than 4 years of experience in critical care ultrasound; they were certified by the Chinese Critical Care Ultrasound Study Group. SMA flow was measured 1 cm proximal to the abdominal aorta. The insertion angle was <60° . The vessel cross-section was circular. The probe was rotated 90° where the vessel flow was measured and the diameter of the lumen (D) was measured. To minimize errors, it is important to take the average of three measurements in a magnified state. The cross-sectional area of the artery is calculated. Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistance index (RI), time-averaged mean velocity (TAMV), pulsatility index (PI), and blood flow (BF, mL/min) were measured using time-velocity waveform readings according to the calculation software carried by the sonographer. BF=π(D/2)²×TAMV×60, PI=(PSV-EDV)/TAMV, RI=(PSV-EDV)/PSV. 2) Ultrasound score of transabdominal bowel function (AGUIS score) At the time of the ultrasound examination, the operator categorized the situation as "good quality", "poor quality" or "not assessable". The operator categorizes the situation as "good quality," "poor quality," or "not evaluable. The abdomen is then divided into four quadrants, each measuring one point, and the operator examines and scores the diameter of the bowel, changes in bowel folds (e.g., shortening, decreasing), thickness of the bowel wall, layering of the bowel wall, peristalsis, and movement of bowel contents. A total of four scores are obtained, and the average of the four measurements is the (AGIUS) score. (3) Serologic indices of intestinal mucosal epithelial injury Plasma citrulline, plasma intestinal fatty acid binding protein, and D-lactic acid were measured by ELISA. (R&D Systems, Minneapolis, USA). Peripheral blood specimens were obtained and centrifuged, and the resulting plasma was frozen at -20°C and sent to the laboratory for analysis within 1 week. Study Route: Patients with sepsis who met the inclusion criteria were enrolled on the day of enrollment to improve the recording of hemodynamic parameters, measurement of Doppler parameters of intestinal blood flow, and serum specimen retention. Measurements of the above parameters were repeated daily from the first to the third day. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06049979
Study type Observational
Source Peking Union Medical College Hospital
Contact Yuankai Zhou, MD
Phone +00886-10-69152300
Email zhouyuankai@aliyun.com
Status Recruiting
Phase
Start date May 1, 2023
Completion date May 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT04045366 - Impact of Capillary Leak and Hypoalbuminemia on PK/PD of Anidulafungin and Caspofungin in Critically Ill Patients
Completed NCT01411553 - ECG Leadwires: Disposable Versus Cleaned, Reusable N/A
Completed NCT00288743 - Adherence, Efficacy and Safety of an Insulin Protocol in the Critically Ill: A Prospective Observational Study Phase 2
Recruiting NCT03529617 - Pharmacokinetics of Liposomal Amphotericin B in Critically Ill vs. Non-critically Ill Hematological Patients: Exploration of Covariates
Not yet recruiting NCT05564975 - Construction and Application of Pressure Injury Risk Prediction Model for Critically Ill Patients
Recruiting NCT06234787 - Continuous Subcutaneous Glucose Monitoring in Critical Patients
Completed NCT02198950 - Combined Determination of sTREM-1, PCT and CD64 in Diagnosing Sepsis
Recruiting NCT01317381 - ICG- Livertest Versus New Biomarkers as Prognostic Markers in Critically Ill ICG- Livertest Versus New Biomarkers as Prognostic Markers in Critically Ill Phase 4
Completed NCT00470821 - Oral Melatonin in Critically Ill High-risk Patients Phase 4
Completed NCT00460252 - Tight Glycemic Control by eMPC Algorithm in Medical ICU Patients. N/A
Active, not recruiting NCT04793568 - Human Recombinant Interferon Gamma-1b for the Prevention of Hospital-acquired Pneumonia in Critically Ill Patients: a Double-blind, International, Phase 2, Randomized, Placebo-controlled Trial - the PREV-HAP Study Phase 2
Recruiting NCT05458687 - Traditional Chinese Medicine for Complications in Critically Ill Patients N/A
Completed NCT01963013 - Non-returning Catheter Valve for Reducing CAUTI N/A
Completed NCT01794468 - A New Monitor to Measure Dermal Blood Flow in Critically Ill Patients: a Preliminary Study N/A
Completed NCT03469882 - High Protein Intake and Early Exercise in Adult Intensive Care Patients N/A
Recruiting NCT04962204 - Virtual Visitation in Intensive Care Unit Study N/A
Completed NCT03205592 - Ultrasound Assessment of Residual Gastric Content in Critically Ill Patients
Recruiting NCT01995565 - Regional Cerebral Hemodynamics Related to Global Hemodynamics N/A
Completed NCT00143494 - The Estimation of Abdominal Pressure by the Bladder and Gastric Pressure N/A
Completed NCT00590928 - Gastric pH in Critically Ill Patients Phase 4