Clinical Trial Details
— Status: Completed
Administrative data
NCT number |
NCT05079308 |
Other study ID # |
UBalearicIslands |
Secondary ID |
|
Status |
Completed |
Phase |
N/A
|
First received |
|
Last updated |
|
Start date |
March 1, 2021 |
Est. completion date |
August 31, 2021 |
Study information
Verified date |
October 2021 |
Source |
University of the Balearic Islands |
Contact |
n/a |
Is FDA regulated |
No |
Health authority |
|
Study type |
Interventional
|
Clinical Trial Summary
A significant number of professionals subjected to high-risk situations have been infected by
Covid-19, due to the lack of adequate respiratory protection equipment or poor marginal
sealing adjustments. Then, the objective of this study is to determine if there are
statistically significant differences in the level of respiratory protection of type IIR
surgical face masks and filtering face masks, used with and without a peripheral sealing
device, against the contagion of Covid-19 or other harmful biological agents. The proposed
device is a thermoplastic resin ring composed of a reusable and biodegradable polylactic acid
designed to be used in a healthcare environment. The individuals of the study will be
submitted to qualitative fit tests, that meet current Ocupational Security and Health
Administration (OSHA) standard. The mentioned qualitative fit test uses a sodium saccharin
solution to evaluate the respiratory protection equipment in professionals in hospitals,
emergency centers, and early childhood education centers.
Description:
The purpose of the research is to determine if there are statistically significant
differences in the level of respiratory protection in situations of high risk against the
contagion of Covid-19 or other harmful biological agents, in subjects who use filtering face
pieces (FFP2) with or without a peripheral sealing device (AMS), Type IIR surgical face masks
with or without a AMS, and subjects using the FFP2 filtering face mask simultaneously with
the Type IIR surgical face mask. For this, a total of 210 individuals were selected from
different environments in order to attain diversity, while controlling for representativeness
bias. They were selected from the ADEMA University School - UIB, nursing staff from the
Infectious Diseases Service at Son Espases University Hospital, 112 Emergency Service of the
Autonomous Community of the Balearic Islands and the General Directorate of Planning and
Centers of the Ministry of Education and Professional Training (Balearic Islands, Spain).
Participants were assigned to one of the 5 groups and subgroups, after accepting their
participation in the study voluntarily and freely by signing the consent form approved by the
CEI-IB.
To evaluate the adjustment of the respiratory protective equipment with and without the
personalized peripheral sealing device (AMS), a sweet sensitivity test was performed with the
3M FT-10 Qualitative Fit-Test Kit (Saint Paul, Minnesota, USA), which complies with the
current standards of the Occupational Security and Health Administration (OSHA) and according
to the protocol described in Riutord-Sbert et al. (2021). During the qualitative fit test, a
total of seven mobility exercises of 60 seconds each were performed, and the nebulizer was
squeezed, every 30 seconds:
Phase 1 - Normal breathing Phase 2 - Slow and deep breathing Phase 3 - Breathing whilst
moving the head to both sides Phase 4 - Breathing whilst moving the head up and down Phase 5
- Breathing spelling the alphabet Phase 6 - Breathing whilst moving up and down from the
waist Phase 7 - Normal breathing
If the fit test was completed within 7 minutes without the individual having detected the
sweet taste, the seal was considered optimal or adequate and the experiment was graded as
APPROVED. If the subject detected the sweet test before seven minutes, the adjustment was
considered inadequate and was scored as FAILED, noting the time it took to detect the sweet
taste as established in the protocol of the 3M FT-10 Fit test (Riutord-Sbert et al. 2021).