Clinical Trials Logo

Clinical Trial Summary

Recent literature shows that the sensitivity of the PCR tests for the detection of SARS-CoV-2 using saliva samples is close to that using nasopharyngeal swabs. This type of sampling represents a practical advantage since it can be performed by the patient herself/himself and would thus allow to speed up the collection process. It is also less painful and could prevent the rare lesions to the nasal mucosa that can occur when using nasopharyngeal swabs. Rapid Diagnostic Tests for the detection of SARS-CoV-2 antigens have been developed using nasophayngeal swabs and have shown very high sensitivity against PCR, ranging from 93% to 98% when based on laboratory validation, 80% when based on clinical validation.This method offers the considerable advantage to inform the patient of the test result on site, and allow the provision of appropriate recommendations on the spot of testing. The studies performed so far have been conducted using nasopharyngeal samples only. There are no data with saliva yet. It is expected that the RDT would also work on the saliva. Even if slightly less sensitive due to the fact that it detects antigens and not multiplied RNA as PCR does, RDT on saliva could better serve the public health goal to test widely and quickly and have ultimately more COVID cases detected and isolated, and hence reduced transmission. To investigate the case detection rates of both PCR on saliva and nasopharynx and RDT on nasopharynx and saliva, the patient will be taken four samples, two swabs on saliva, one for RDT and one for PCR, and two swabs on nasopharynx, one for RDT and one for PCR. Patients who have at least one of the common symptoms and who consent to such a procedure will be recruited to compare the four results. The primary objective is to compare the case detection rates for SARS-CoV-2 of the four testing methods (two sampling types and two test types).


Clinical Trial Description

Background: Recent literature shows that the sensitivity of the PCR tests for the detection of SARS-CoV-2 using saliva samples is close to that using nasopharyngeal swabs. This type of sampling represents a practical advantage since it can be performed by the patient herself/himself and would thus allow to speed up the collection process. It is also less painful and could prevent the rare lesions to the nasal mucosa that can occur when using nasopharyngeal swabs. Rapid Diagnostic Tests for the detection of SARS-CoV-2 antigens have been developed using nasophayngeal swabs and have shown very high sensitivity against PCR, ranging from 93% to 98% when based on laboratory validation, 80% when based on clinical validation.This method offers the considerable advantage to inform the patient of the test result on site, and allow the provision of appropriate recommendations on the spot of testing. The studies performed so far have been conducted using nasopharyngeal samples only. There are no data with saliva yet. It is expected that the RDT would also work on the saliva. Even if slightly less sensitive due to the fact that it detects antigens and not multiplied RNA as PCR does, RDT on saliva could better serve the public health goal to test widely and quickly and have ultimately more COVID cases detected and isolated, and hence reduced transmission. To investigate the case detection rates of both PCR on saliva and nasopharynx and RDT on nasopharynx and saliva, patients will be taken four samples, two swabs on saliva, one for RDT and one for PCR, and two swabs on nasopharynx, one for RDT and one for PCR. Patients who have at least one of the common symptoms and who consent to such a procedure will be recruited to compare the four results. The primary objective is to compare the case detection rates for SARS-CoV-2 of the four testing methods (two sampling types and two test types). Methods: Procedures: Patients fulfilling inclusion and exclusion criteria will be recruited consecutively. After confirmation of inclusion and exclusion criteria, patients will be asked whether they would be willing to provide two saliva samples and one nasopharyngeal swab in addition to that provided for routine testing. After written informed consent, patients will be asked to perform swabbing of the gingiva-buccal fold two times and a saliva sample under professional supervision, once for sending to the laboratory to perform PCR, and once for performing the RDT onsite according to manufacturer's information. They will also be taken two nasopharyngeal swabs, one for RDT and one for PCR. No coughing or sniffing prior to sample collection is required. Ideally, water should be avoided 10 minutes prior to collection. Other drinks, food, and nasal sprays should be avoided 20 minutes before sample collection. The saliva and nasopharyngeal samples will be analysed by PCR according to the standard procedure. The RDTs will be performed and results read according to the manufacturer information (see below). Alternatively one of the three following tests will be tested: RDT from Roche (Standard Q COVID-19, the RDT from Abbott (Panbio COVID-19 Ag) and the RDT from AAZ-LMB (COVID-VIRO). The patient will be considered as positive for SARS-CoV-2 if any of the test results (by RDT, or PCR on saliva or nasopharynx) is positive. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04613310
Study type Interventional
Source Center for Primary Care and Public Health (Unisante), University of Lausanne, Switzerland
Contact Valérie D'Acremont, MD PhD
Phone +41 79 556 25 51
Email valerie.dacremont@unisante.ch
Status Recruiting
Phase N/A
Start date September 25, 2020
Completion date December 31, 2020

See also
  Status Clinical Trial Phase
Withdrawn NCT06065033 - Exercise Interventions in Post-acute Sequelae of Covid-19 N/A
Completed NCT06267534 - Mindfulness-based Mobile Applications Program N/A
Completed NCT05047601 - A Study of a Potential Oral Treatment to Prevent COVID-19 in Adults Who Are Exposed to Household Member(s) With a Confirmed Symptomatic COVID-19 Infection Phase 2/Phase 3
Recruiting NCT04481633 - Efficacy of Pre-exposure Treatment With Hydroxy-Chloroquine on the Risk and Severity of COVID-19 Infection N/A
Recruiting NCT05323760 - Functional Capacity in Patients Post Mild COVID-19 N/A
Completed NCT04612972 - Efficacy, Safety and Immunogenicity of Inactivated SARS-CoV-2 Vaccines (Vero Cell) to Prevent COVID-19 in Healthy Adult Population In Peru Healthy Adult Population In Peru Phase 3
Completed NCT04537949 - A Trial Investigating the Safety and Effects of One BNT162 Vaccine Against COVID-19 in Healthy Adults Phase 1/Phase 2
Recruiting NCT05494424 - Cognitive Rehabilitation in Post-COVID-19 Condition N/A
Active, not recruiting NCT06039449 - A Study to Investigate the Prevention of COVID-19 withVYD222 in Adults With Immune Compromise and in Participants Aged 12 Years or Older Who Are at Risk of Exposure to SARS-CoV-2 Phase 3
Enrolling by invitation NCT05589376 - You and Me Healthy
Completed NCT05158816 - Extracorporal Membrane Oxygenation for Critically Ill Patients With COVID-19
Recruiting NCT04341506 - Non-contact ECG Sensor System for COVID19
Completed NCT04512079 - FREEDOM COVID-19 Anticoagulation Strategy Phase 4
Completed NCT04384445 - Zofin (Organicell Flow) for Patients With COVID-19 Phase 1/Phase 2
Completed NCT05975060 - A Study to Evaluate the Safety and Immunogenicity of an (Omicron Subvariant) COVID-19 Vaccine Booster Dose in Previously Vaccinated Participants and Unvaccinated Participants. Phase 2/Phase 3
Active, not recruiting NCT05542862 - Booster Study of SpikoGen COVID-19 Vaccine Phase 3
Terminated NCT05487040 - A Study to Measure the Amount of Study Medicine in Blood in Adult Participants With COVID-19 and Severe Kidney Disease Phase 1
Withdrawn NCT05621967 - Phonation Therapy to Improve Symptoms and Lung Physiology in Patients Referred for Pulmonary Rehabilitation N/A
Terminated NCT04498273 - COVID-19 Positive Outpatient Thrombosis Prevention in Adults Aged 40-80 Phase 3
Active, not recruiting NCT06033560 - The Effect of Non-invasive Respiratory Support on Outcome and Its Risks in Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2)-Related Hypoxemic Respiratory Failure