Coronary Restenosis Clinical Trial
Use of SeQuent® Please drug coated balloon (DCB) is effective to treat patients with in-stent restenosis (ISR). However, whether the type of pre-dilatation balloon prior to DCB dilatation impacts on clinical and angiographic outcomes or not is unknown. Lacrosse® Non-slip element balloon (NSE) is a balloon catheter with 3 longitudinal plastic elements which are attached to proximal and distal balloon edges. NSE is developed to incise neointimal tissue and avoid balloon slippage without vitiating balloon derivability and crossability. We investigated angiographic and clinical outcomes following normal non-compliant balloon or NSE dilatation prior to DCB dilatation in ISR lesions.This study is a single blinded, multicenter, randomized trial. Total 200 patients with ISR are randomly assigned to treat with non-compliant balloon or NSE before DCB dilatation. Optical coherence tomographic (OCT) analysis are performed before pre-dilatation and after DCB dilatation Follow-up angiography analysis are planned at 8 months in all patients. Clinical follow-up is planned at 8 and 24 months.Primary endpoint is angiographic in-segment late loss at 8 months.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01205776 -
EXCEL Clinical Trial
|
N/A | |
Active, not recruiting |
NCT04475380 -
Complex All-comers and Patients With Diabetes or Prediabetes, Treated With Xience Sierra Everolimus-eluting Stents
|
||
Completed |
NCT02263313 -
EGO-COMBO Clinical End-point Extension Study Beyond 36 Months
|
N/A | |
Completed |
NCT00248066 -
Safety and Efficacy of RESTEN-MP When Used in Conjunction With a Bare Metal Stent in Coronary Arteries
|
Phase 2 | |
Completed |
NCT00148356 -
Safety and Efficacy of the ZoMaxx™ Drug-Eluting Stent System in Coronary Arteries
|
Phase 2/Phase 3 | |
Active, not recruiting |
NCT02508714 -
Bioresorbable Polymer ORSIRO Versus Durable Polymer RESOLUTE ONYX Stents
|
N/A | |
Completed |
NCT01274234 -
OCT Evaluation of Healing of COMBO Stent
|
Phase 1/Phase 2 | |
Completed |
NCT01205789 -
EXCEL Clinical Trial (Universal Registry)
|
N/A | |
Recruiting |
NCT00426049 -
Systemic Treatment With Everolimus for the Prevention of MACE After Bare Metal Stent Implantation
|
Phase 3 | |
Terminated |
NCT00243308 -
Serp-1 for the Treatment of Acute Coronary Syndrome
|
Phase 2 | |
Completed |
NCT00180466 -
PROSPECT: An Imaging Study in Patients With Unstable Atherosclerotic Lesions
|
N/A | |
Completed |
NCT00859183 -
Oral Sirolimus for In-Stent Restenosis
|
Phase 4 | |
Completed |
NCT03667313 -
Treatment of In-Stent Restenosis 2 Study
|
Phase 3 | |
Recruiting |
NCT05089864 -
STAR and Deferred Stenting Study
|
N/A | |
Active, not recruiting |
NCT02175706 -
DUrable Polymer-based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity
|
N/A | |
Completed |
NCT01331707 -
DUrable Polymer-based STent CHallenge of Promus Element Versus ReSolute Integrity in an All Comers Population
|
Phase 4 | |
Completed |
NCT01249027 -
XIENCE V Everolimus Eluting Coronary Stent System (EECSS) China: Post-Approval, Single-Arm Study
|
||
Recruiting |
NCT00500279 -
Effects of Celecoxib On Restenosis After Coronary Intervention and Evolution of Atherosclerosis Trial
|
Phase 4 | |
Completed |
NCT01171820 -
SPIRIT V: A Clinical Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Coronary Artery Lesions (Diabetic Sub-Study)
|
Phase 4 | |
Completed |
NCT00402272 -
SPIRIT V: Post-marketing Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System in Europe
|
Phase 4 |