Clinical Trials Logo

Clinical Trial Summary

The PACCOCATH ISR II study is a randomized, double-blinded German multicenter trial on the efficacy and tolerance of a paclitaxel coated balloon catheter in coronary in-stent restenosis.


Clinical Trial Description

Background: Drug-eluting stents have shown promising anti-restenotic effects in clinical trials. It may be preferable, however, to avoid the stent-in-stent approach in treating in-stent restenosis (ISR). In prior animal trials, we demonstrated a highly significant reduction of neointimal formation by drug-eluting balloon catheters (DEB). The aim of the PACCOCATH ISR study is to investigate the novel DEB in the treatment of ISR.

Methods and results: The PACCOCATH ISR study is a randomized, double-blind German multicenter trial on the efficacy and tolerance of the DEB in coronary ISR. Patients are randomized to rePTCA of ISR either using the coated PTCA balloon (3 µg paclitaxel/mm² balloon surface) or a non-coated balloon of the same type (n=56 patients). Balloon inflation time is 60 seconds in both cases. Major inclusion criteria are an ISR in a coronary artery with a diameter stenosis of at least 70%, < 30 mm length, and a vessel diameter of 2.5 to 3.5 mm. The primary endpoint is late lumen loss after 6 months (independent angiographic core lab). Secondary endpoints are binary restenosis rate and major adverse cardiac events. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double-Blind, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00409981
Study type Interventional
Source University Hospital, Saarland
Contact
Status Completed
Phase Phase 1/Phase 2
Start date July 2004
Completion date June 2006

See also
  Status Clinical Trial Phase
Completed NCT01205776 - EXCEL Clinical Trial N/A
Active, not recruiting NCT04475380 - Complex All-comers and Patients With Diabetes or Prediabetes, Treated With Xience Sierra Everolimus-eluting Stents
Completed NCT02263313 - EGO-COMBO Clinical End-point Extension Study Beyond 36 Months N/A
Completed NCT00248066 - Safety and Efficacy of RESTEN-MP When Used in Conjunction With a Bare Metal Stent in Coronary Arteries Phase 2
Completed NCT00148356 - Safety and Efficacy of the ZoMaxx™ Drug-Eluting Stent System in Coronary Arteries Phase 2/Phase 3
Active, not recruiting NCT02508714 - Bioresorbable Polymer ORSIRO Versus Durable Polymer RESOLUTE ONYX Stents N/A
Completed NCT01274234 - OCT Evaluation of Healing of COMBO Stent Phase 1/Phase 2
Completed NCT01205789 - EXCEL Clinical Trial (Universal Registry) N/A
Recruiting NCT00426049 - Systemic Treatment With Everolimus for the Prevention of MACE After Bare Metal Stent Implantation Phase 3
Terminated NCT00243308 - Serp-1 for the Treatment of Acute Coronary Syndrome Phase 2
Completed NCT00180466 - PROSPECT: An Imaging Study in Patients With Unstable Atherosclerotic Lesions N/A
Completed NCT00859183 - Oral Sirolimus for In-Stent Restenosis Phase 4
Completed NCT03667313 - Treatment of In-Stent Restenosis 2 Study Phase 3
Recruiting NCT05089864 - STAR and Deferred Stenting Study N/A
Active, not recruiting NCT02175706 - DUrable Polymer-based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity N/A
Completed NCT01331707 - DUrable Polymer-based STent CHallenge of Promus Element Versus ReSolute Integrity in an All Comers Population Phase 4
Completed NCT01249027 - XIENCE V Everolimus Eluting Coronary Stent System (EECSS) China: Post-Approval, Single-Arm Study
Recruiting NCT00500279 - Effects of Celecoxib On Restenosis After Coronary Intervention and Evolution of Atherosclerosis Trial Phase 4
Completed NCT00402272 - SPIRIT V: Post-marketing Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System in Europe Phase 4
Completed NCT01171820 - SPIRIT V: A Clinical Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Coronary Artery Lesions (Diabetic Sub-Study) Phase 4