Clinical Trials Logo

Clinical Trial Summary

The TRANSLUMINA GmbH YuChooSeR Observatory is a prospective, multicentric post-marketing observatory designed to evaluate large scale safety and reliability of the Yukon Choice PC and the Yukon Chrome PC stents systems use in routine, clinical practice. This based observatory will enroll 3000 patients to 30 sites in France.


Clinical Trial Description

TRANSLUMINA GmbH has launched clinical programs to demonstrate the safety and efficacy of its technology. The Translumina Yukon Choice PC drug-eluting stent, coated with Rapamycin (Sirolimus) and the biodegradable component polylactide (PLA), has an excellent history of pre-clinical and clinical results. The Yukon Chrome PC has the identical coating technique and coating properties (dosage, thickness) like the clinically proven Yukon Choice PC. In two independent trials ISAR-TEST 3 and ISAR-TEST 4 the Yukon DES platform showed angiographic and clinical equivalence with the Cypher stent after 1 year and 3 years of follow-up. Latest clinical data, published by G.Stefanini et al, show the excellent long-term outcome of the Yukon biodegradable polymer DES technology in a meta-analysis, comparing the clinical outcome after 4 years in more than 4000 patients with the Cypher stent. This analysis shows for the first time that the definite Very Late Stent Thrombosis (VLST) can be reduced statistically significant by using the biodegradable PLA polymer coating technology of the Yukon DES. An additional sub-group analysis shows also benefit in difficult patient groups like diabetics and patients with acute myocardial infarkt. Due to this excellent clinical outcome the Yukon DES technology is recommended by the latest ESC guidelines for myocardial revascularization. The final 5 years long-term clinical follow-up of the ISAR-TEST 4 randomized controlled clinical trial showed excellent safety and efficacy data for the Yukon DES when compared with the Cypher and Xience V stent. The definite and probable stent thrombosis was only 1,2% for the Yukon compared to 1,4% and 2,4% for the 2 permanent polymer coated competitor DES. In a continued approach to collect safety and efficiency data on its products, TRANSLUMINA GmbH is determined to collect safety and efficiency information at a very large scale. Based on all this, the Yukon Choice PC & the Yukon Chrome PC stents have been designed to treat coronary arteries in a relatively easy and simple-to-achieve manner, while providing a higher level of clinical efficacy. Additionally, the Observatory is aimed to provide a learning tool that will help to define best practices/techniques as all results will be fed back to participants and to a larger audience through publications. In this Observatory, analyses will be performed per clinical presentation and per stent type. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03918070
Study type Observational
Source Translumina GmbH
Contact
Status Active, not recruiting
Phase
Start date April 17, 2019
Completion date May 24, 2024

See also
  Status Clinical Trial Phase
Completed NCT02156245 - Evaluation of the Effects of Eccentric Training on a Cycle Ergometer, Versus Conventional Concentric Training N/A
Withdrawn NCT00817830 - Cardiovascular Safety Study of Lodenafil Carbonate in Patients With Coronaropathy During Physical Effort Phase 4
Completed NCT02258620 - Prevention and Comparison of Different Forms of Administration of Nitrates in the Risk of Radial Spasm During Coronary Angiography. N/A
Active, not recruiting NCT03842813 - Safety and Performance Assessment of Drug-Eluting Stent CRE8 in Diabetic Patients