Clinical Trials Logo

Clinical Trial Details — Status: Unknown status

Administrative data

NCT number NCT00834782
Other study ID # SHEBA-09-6902-IDF-CTIL
Secondary ID
Status Unknown status
Phase Phase 4
First received February 2, 2009
Last updated September 13, 2009
Start date May 2009
Est. completion date May 2010

Study information

Verified date September 2009
Source Sheba Medical Center
Contact Ido Didi Fabian, Dr
Phone +9727830444
Email didifabian@gmail.com
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

To compare intraocular pressure (IOP) measured by the Reichert Ocular Response Analyzer (ORA), Pascal dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT) in eyes after Penetrating Keratoplasty (KPL)


Description:

A few tonometers are used today in clinical practice for measuring intra ocular pressure (IOP). Each tonometer is based on different technology.

Post penetrating keratoplasty (PK) eyes are at risk for developing secondary glaucoma (9-14%). Elevation of the IOP may cause rejection of the graft or alternately a loss in the endothelial cell layer count causing decompensation of the cornea. Therefore, measuring accurately the IOP in this population is of great importance.

Measuring IOP in post PK is not an easy challenge, mainly because of parameters like the central corneal thickness (CCT), the curvature of the cornea, the axial length and biomechanical properties which diverse from normal eyes.

The Goldmann applanation tonometer (GAT) is the gold standard tonometer for measuring IOP and is the most popular tonometer clinically used. IOP measurements via the GAT are based on the assumption that the CCT is constant. post PK eyes CCT might diverse from normal eyes causing GAT IOP measurements to be inaccurate. The Pascal dynamic contour tonometer (DCT) measures IOP independently of corneal parameters. The Ocular response analyzer (ORA) is based on a non contact technique of measurement. The tonometer is thought to be independent of factors such as CCT.

The aim of the study is to compare intraocular pressure (IOP) measured by the Reichert Ocular Response Analyzer (ORA), Pascal dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT) in eyes after Penetrating Keratoplasty (KPL). In addition its aim is to discover the dependence of different parameters, like - CCT, curvature of the cornea, axial length and biomechanical properties on IOP measurement to elucidate the appropriate tonometer for this population.


Recruitment information / eligibility

Status Unknown status
Enrollment 35
Est. completion date May 2010
Est. primary completion date December 2009
Accepts healthy volunteers No
Gender All
Age group 18 Years to 90 Years
Eligibility Inclusion Criteria:

- Eyes after KPL surgery at the Goldschleger Eye Institute in the last 10 years.

Exclusion Criteria:

- Uncooperative subjects for whom good quality results are unattainable.

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
IOP measurement
Measuring IOP

Locations

Country Name City State
Israel Goldschleger eye institute, Sheba medical center Ramat Gan
Israel The Goldschleger eye institute, Sheba Medical Center, Tel Aviv University Ramat Gan

Sponsors (1)

Lead Sponsor Collaborator
Sheba Medical Center

Country where clinical trial is conducted

Israel, 

References & Publications (9)

Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006 May;141(5):868-75. Epub 2006 Mar 9. — View Citation

Jain AK, Saini JS, Gupta R. Tonometry in normal and scarred corneas, and in postkeratoplasty eyes: a comparative study of the Goldmann, the ProTon and the Schiotz tonometers. Indian J Ophthalmol. 2000 Mar;48(1):25-32. — View Citation

Kerautret J, Colin J, Touboul D, Roberts C. Biomechanical characteristics of the ectatic cornea. J Cataract Refract Surg. 2008 Mar;34(3):510-3. doi: 10.1016/j.jcrs.2007.11.018. — View Citation

Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005 Jan;31(1):156-62. — View Citation

Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006 Oct;15(5):364-70. — View Citation

Mollan SP, Wolffsohn JS, Nessim M, Laiquzzaman M, Sivakumar S, Hartley S, Shah S. Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in keratoconic and normal eyes. Br J Ophthalmol. 2008 Dec;92(12):1661-5. doi: 10.1136/bjo.2007.136473. Epub 2008 Aug 29. — View Citation

Pandav SS, Sharma A, Gupta A, Sharma SK, Gupta A, Patnaik B. Reliability of proton and goldmann applanation tonometers in normal and postkeratoplasty eyes. Ophthalmology. 2002 May;109(5):979-84. — View Citation

Rao VJ, Gnanaraj L, Mitchell KW, Figueiredo FC. Clinical comparison of ocular blood flow tonometer, Tonopen, and Goldmann applanation tonometer for measuring intraocular pressure in postkeratoplasty eyes. Cornea. 2001 Nov;20(8):834-8. — View Citation

Touboul D, Roberts C, Kérautret J, Garra C, Maurice-Tison S, Saubusse E, Colin J. Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry. J Cataract Refract Surg. 2008 Apr;34(4):616-22. doi: 10.1016/j.jcrs.2007.11.051. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Intra ocular pressure 1 year
Secondary Corneal compensated intra ocular pressure, Corneal hysteresis, Corneal resistance factor 1 year
See also
  Status Clinical Trial Phase
Recruiting NCT01206127 - DSAEK- Postoperative Positioning and Transplant Dislocation N/A
Terminated NCT00764582 - Ocular Penetration of 1.5% Levofloxacin and 0.5% Moxifloxacin During Corneal Transplant Surgery Phase 4
Recruiting NCT05870566 - Pretreatment to Promote Graft Survival After Subsequent High-risk Corneal Transplantation [CrossCornealVision] N/A
Recruiting NCT02084745 - Timing of Glaucoma Drainage Device With Boston Keratoprosthesis N/A
Withdrawn NCT00345020 - Deep Lamellar Endothelial Keratoplasty: Small Incision Technique
Completed NCT00000137 - Collaborative Corneal Transplantation Studies (CCTS) Phase 3
Recruiting NCT04339907 - Inflammatory Mediators of Glaucoma After Corneal Transplantation (AH-Tears) N/A
Active, not recruiting NCT00874835 - Corneal Endothelium Delivery Instrument Phase 2
Completed NCT00570648 - A Prospective Study of the Effect of Topical Sodium Hyaluronate Immediately Post-PKP on Time to Reepithelialization N/A
Enrolling by invitation NCT03461978 - Ultrahigh-resolution Optical Coherence Tomography Imaging of the Anterior Eye Segment Structures N/A
Not yet recruiting NCT05210478 - Intraoperative Optical Coherence Tomography for Ophthalmic Surgical Guidance - Cornea
Completed NCT01694914 - Comparative Study of Two Corneal Graft Storage Media: New Animal Compound Free Medium Versus Reference Medium Phase 3
Completed NCT03381794 - The German Keratoplasty Registry of the German Ophthalmological Society (DOG) N/A
Recruiting NCT03105466 - Prospective Study of Deep Anterior Lamellar Keratoplasty Using Acellular Porcine Cornea N/A
Completed NCT00409656 - Prospective, Randomized Trial of Basiliximab (Simulect) in the Prophylaxis of High-Risk Keratoplasty Patients Phase 2
Recruiting NCT01018888 - Safety and Efficacy Study of Artificial Cornea Phase 4
Recruiting NCT04490902 - Clinical Study on the Treatment of Mixed Component Cornea for High Risk Keratoplasty N/A
Recruiting NCT04337944 - Endoscopic Assisted Anterior Hyaloid Peeling in Boston Type 1 Keratoprosthesis (KPro-HP-Endo) N/A
Completed NCT01547975 - Retrospective Analysis of Surgical Outcomes After Corneal Transplantation N/A
Terminated NCT00447642 - Study to Assess LX201 for Prevention of Corneal Allograft Rejection or Graft Failure in Subjects Who Have Experienced One or More Rejection Episodes Following Penetrating Keratoplasty Phase 3