Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03010748
Other study ID # Tianjin EH-pentacam
Secondary ID
Status Recruiting
Phase
First received
Last updated
Start date November 2015
Est. completion date December 2019

Study information

Verified date May 2018
Source Tianjin Eye Hospital
Contact Yan Wang, director
Phone +86-02227305083
Email wangyan7143@vip.sina.com
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Based on the corneal morphometry instrumentation Oculus Pentacam, which is commonly used before and after clinical refractive surgery, we will collect the corneal morphological and biologic parameters of the population under refractive surgery screening in refractive surgery centers around the country, and construct corneal morphology database in different living areas of Chinese people. Based on this, compared with the suspected keratoconus and keratoconus population, the screening criteria and reference standards accord with the characteristics of keratoconus of Chinese ethnic will be achieved.


Description:

The safety of refractive surgery has always been the focus of attention, keratoconus screening is the most important part for the preoperative examination of refractive surgery. Favorable tools and appropriate indicators are the premise of fast and accurate screening, and the corneal morphology from various regions of China have various characteristics, the use of uniform standards developed by foreign screening will always induce a lot of problems, for example, the differences of cornea morphological features between European and American ethnic and Chinese race, as well as the corneal morphometric indicators between various regions of China, will cause varying degrees of false-positive or false-negative screening results. Based on this, in order to further improve the safety of refractive surgery effectively and to obtain the effective and accurate screening of suspected keratoconus population, this study will be conducted to collect the corneal morphological characteristics database of Chinese people from all over the country, and to develop a database of Chinese ethnographic characteristics for screening keratoconus indicators and reference valuable to guide clinical screening and surgical design.


Recruitment information / eligibility

Status Recruiting
Enrollment 50000
Est. completion date December 2019
Est. primary completion date August 2019
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

- No less than 18 years old, in good health, have no active disease in the body and eye, have permanent resident status and have lived in the local area for at least 5 years (please mark the nation).

Exclusion Criteria:

- Eye diseases, glaucoma, ocular hypertension, glaucoma patients with normal pressure, fundus lesions, ptosis and other eyelid abnormalities.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Scheimpflug tomography system (Pentacam) measurement
The Scheimpflug tomography system (Pentacam,Oculus GmbH, Wetzlar, Germany) is a rotating Scheimpflug camera that measures 138,000 true elevation points to compute corneal topography. Patients were asked to blink twice and then look at the fixation device. Image acquisition was a 2-second scan of 50 rotational Scheimpflug images through the corneal sighting point, the point where the ray of light from the fovea to the fixation device crossed the cornea. All measurements were performed just after a blink to minimize the effect of tear film alteration on the data. Acceptable maps had at least 10.0 mm of corneal coverage with no extrapolated data in the central 9.0 mm zone.

Locations

Country Name City State
China Tianjin Eye Hospital Tianjin

Sponsors (7)

Lead Sponsor Collaborator
Tianjin Eye Hospital Gansu Provincial Hospital, Health Science Center of Xi’an Jiaotong University, Jilin University, Second People's Hospital of Yunnan Province, Wuhan General Hospital of Guangzhou Military Command, Xinjiang Medical University

Country where clinical trial is conducted

China, 

References & Publications (4)

Chan TCY, Biswas S, Yu M, Jhanji V. Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging. Acta Ophthalmol. 2017 Sep;95(6):e486-e494. doi: 10.1111/aos.13298. Epub 2016 Nov 2. — View Citation

Naderan M, Rajabi MT, Zarrinbakhsh P, Farjadnia M. Is keratoconus more severe in pediatric population? Int Ophthalmol. 2016 Oct 25. [Epub ahead of print] — View Citation

Patrão LF, Canedo AL, Azevedo JL, Correa R, Ambrósio R Jr. Differentiation of mild keratoconus from corneal warpage according to topographic inferior steepening based on corneal tomography data. Arq Bras Oftalmol. 2016 Jul-Aug;79(4):264-7. doi: 10.5935/0004-2749.20160075. — View Citation

Silverman RH, Urs R, RoyChoudhury A, Archer TJ, Gobbe M, Reinstein DZ. Combined tomography and epithelial thickness mapping for diagnosis of keratoconus. Eur J Ophthalmol. 2017 Mar 10;27(2):129-134. doi: 10.5301/ejo.5000850. Epub 2016 Aug 8. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary corneal thickness preoperative
Secondary corneal curvature measured by the Pentacam system preoperative
Secondary coma aberration measured by the Pentacam system preoperative
Secondary aspherical index measured by the Pentacam system preoperative
Secondary spherical aberration measured by the Pentacam system preoperative
Secondary corrected distance visual acuity preoperative
Secondary uncorrected distance visual acuity preoperative
Secondary refractive diopter preoperative
Secondary corneal volume measured by the Pentacam system preoperative
Secondary kapple angle measured by the Pentacam system preoperative
Secondary introcular pressure preoperative
Secondary corneal diameter measured by the Pentacam system preoperative
Secondary anterior chamber depth measured by the Pentacam system preoperative
Secondary anterior chamber angle measured by the Pentacam system preoperative
See also
  Status Clinical Trial Phase
Terminated NCT03674892 - Intranasal Neurostimulation in Ameliorating Symptoms of Neuropathic Corneal Pain N/A
Recruiting NCT04439552 - fMRI and IVCM Cornea Microscopy of CXL in Keratoconus
Not yet recruiting NCT04122651 - Toric Intraocular Lenses for Cataract Patients in the NHS N/A
Recruiting NCT03299530 - Accuracy of Corneal Astigmatism in Different Region Modes
Completed NCT04560790 - Safety and Efficacy of CRISPR/Cas9 mRNA Instantaneous Gene Editing Therapy to Treat Refractory Viral Keratitis N/A
Completed NCT02293122 - To Investigate Agreement Between the EM-3000 and the Predicate Device Noncon Robo Pachy (F&A) (CellChek XL)
Active, not recruiting NCT06389916 - Euclid Phoenix Lens Design Trial N/A
Completed NCT06353776 - MicroPulse Transscleral Laser Therapy and Its Short-term Impact on Ocular Surface N/A
Completed NCT03906513 - Evaluation of the Efficacy of OMK2 in Recovering Corneal Neural Damage in Patients With Diabetes N/A
Not yet recruiting NCT06392607 - Euclid Phoenix Lens Design Trial 2 N/A
Recruiting NCT05232539 - Efficiency of Intraoperative Optical Coherence Tomography (iOCT) N/A
Completed NCT02781948 - Evaluation of the Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With iVue SD-OCT N/A
Not yet recruiting NCT05345652 - Evaluation Of Deep Anterior Lamellar Keratoplasty By Anterior Segment Ocular Coherence Tomography
Completed NCT04804592 - Investigation in Corneal Sensation and Contact Lens Wear N/A
Recruiting NCT04626583 - Safety of Locally Delivered Allogeneic Mesenchymal Stromal Cells Phase 1
Recruiting NCT04323358 - Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract N/A
Completed NCT06277349 - Multifocal-toric IOL Compared to Multifocal IOL Combined With Limbal Relaxing Incisions for Correction of Moderate Astigmatism During Cataract Surgery N/A
Withdrawn NCT02395952 - Healing of Persistent Epithelial Defects N/A
Completed NCT03518775 - Repeatability and Reproducibility of the IOLMaster 700 Vers 1.70 and Agreement With IOLMaster 700 Vers. 1.50 and Pentacam
Terminated NCT04969406 - A Prospective Trial of the Intelon BOSS(TM) System N/A