Clinical Trials Logo

Clinical Trial Summary

Fourteen completely edentulous patients were selected to participate in this study. From the outpatient clinic of Prosthodontic Department, Faculty of Dentistry, Ain Shams University. After fabrication of complete denture for all patients, patients were randomly divided to: Group A: Seven patients were rehabilitated with implant retained maxillary overdenture where four Straumann BLX® implant were inserted opposed by mandibular complete denture. Group B: Seven patients were rehabilitated with implant retained maxillary overdenture where four conventional acid etched implants were inserted opposed by mandibular complete denture. After implant placement using surgical guide, smart peg and ostell device were used to measure the primary stability of the implant then cover screw was placed and after six weeks, secondary stability was measured for both groups. After four months, the second stage started in which exposure of the implant fixtures took place and pick up was carried out. Patients were recalled frequently for post-insertion inspection and adjustment.


Clinical Trial Description

Background: long term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla which is categorized as type III & IV bone, so searching for new innovation and updates in implant material and features is very mandatory. So, the aim of this study was asses and compare between two implant materials roxolid versus traditional titanium on the primary and secondary stability. Methods: eighteen completely edentulous patients were selected they all received maxillary implant retained overdentures and lower complete dentures, they were divided equally in to two groups according to the type of the material of the implants. Group A received a total number of 36 (Roxolid) Implants were made of roxolid material and Group B received a total number 36 (Titanium) implants were made of traditional titanium alloys. Implant stability was assed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and independent t-test was used to compare between the two groups with a significant level < 0.05. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06334770
Study type Interventional
Source Ain Shams University
Contact
Status Completed
Phase N/A
Start date June 15, 2021
Completion date December 12, 2023

See also
  Status Clinical Trial Phase
Completed NCT04694209 - Patient Satisfaction and OHRQoL In Removable Versus Fixed Implant Prostheses N/A
Not yet recruiting NCT03814070 - Prosthesis and Implant Survival in Immediately Loaded Temporary Full Arch Restorations N/A
Completed NCT05585008 - Three Dimensional Printed Versus Conventional Heat Cured Acrylic Complete Denture N/A