Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01607827
Other study ID # EK-1066
Secondary ID
Status Completed
Phase N/A
First received May 24, 2012
Last updated June 18, 2012
Start date April 2004
Est. completion date April 2007

Study information

Verified date June 2012
Source University of Zurich
Contact n/a
Is FDA regulated No
Health authority Switzerland: Ethikkommission
Study type Interventional

Clinical Trial Summary

The investigators aim to assess the procedure time and miss rate of polyps when performing polypectomy in the colon on the way up* and down** or only on the way down**.

(* advancing the scope to the cecum, ** pulling back the scope after intubation of the cecum). Our hypothesis is that using the strategy to remove all visible polyps firstly on the way up and secondly on the way down is less time consuming and misses less polyps as with the strategy to remove polyps only on the way down.


Description:

Patients with a referral for a complete colonoscopy were included in the study. Polyps were removed upon insertion and withdrawal of the colonoscope in Group A or only upon withdrawal of the instrument in Group B according to a computer-generated randomization list.

The following inclusion criteria were used: referral for a complete colonoscopy and age of 18 years and older. All patients with polyps detected during colonoscopy were included. In order to compare the time required for the entire endoscopy between the two treatment groups, we only included patients with polyps of up to 10 mm in diameter.

The following exclusion criteria were applied: colonoscopy due to bleeding, high likelihood of colonic stenosis or severe inflammation, inflammatory bowel disease (IBD), hereditary colonic polyp disease (FAP or HNPCC), contraindications for polypectomy, such as coagulopathy, use of anti-clotting medication (anticoagulation, high-dose heparin aspirin, NSAIDs), polyps >10 mm in diameter (that cannot be removed through the biopsy channel and have to be removed by basket or polyp grasper; the use of these devices necessitates removal and consecutive re-insertion of the endoscope, making a comparison of the time intervals between the two groups impossible), suboptimal bowel preparation (presence of significant amounts of fecal remnants that could not be removed by flushing of the colon over the colonoscope and that did not allow clear visualization of the mucosa), and missing signed informed consent form.

The randomization was done as soon as the first polyp was detected. When no polyps were detected, the case was regarded as screening failure and excluded from the study.

Randomization was performed into the following two groups:

Group A: Removal of all visible polyps upon insertion and withdrawal of the instrument Group B: Removal of all visible polyps upon withdrawal of the colonoscope only One day after colonoscopy, patients were asked to complete a questionnaire evaluating the tolerance of the ileo-colonoscopy (on a visual scale from 1 to 4 where 1 stands for no discomfort, 2 for minor discomfort, 3 for moderate discomfort, and 4 for severe discomfort associated with the endoscopy).

Endoscopic procedures:

Colon preparation was performed using 3 liters of PEG-based standard lavage fluids (Fordtran Streuli ®, Streuli Pharma, Switzerland).

The procedures were performed by senior endoscopists (SW, SRV, HF, NW, PB) with at least 5 years of experience in colonoscopy and performing at least 200 colonoscopies per year. All endoscopists participating in this trial underwent a specific study training headed by SW. Polyp size was measured using an opened biopsy forceps (Boston Scientific Radial JawTM 4, Reference No 1332, diameter of opened jaws 9mm). All endoscopists had comparable numbers of procedures in both approaches to polypectomy.

Premedication consisted mostly of propofol (60-400 mg) or a combination of midazolam (2.5-5 mg) and/or meperidine (25-50 mg) intravenously. Examinations were performed in left lateral decubitus or supine position. Colonic insufflation was performed with room air. All polypectomies in the study groups were performed using the same techniques as in the standard care of non-study patients, using snare loops, hot biopsy forceps, with and without submucosal injection of saline/epinephrine. Polyps larger than 3 mm were removed by snare, polyps smaller than 4 mm were removed by cold biopsy. There were no differences upon insertion or withdrawal.

In Group A, the endoscopist removed all visible polyps instantly regardless whether advancing the instrument to the cecum or pulling back. In Group B, the endoscopist advanced the endoscope to the cecum without removing polyps. Upon withdrawal, all visible polyps were removed successively by standard techniques. In both groups, the endoscopists were instructed to focus on rapid introduction.

Assessments After the endoscopy, the physician completed the data capture sheet evaluating the following criteria: patient demographics, patient history, time intervals required for the procedure, number of polyps detected upon insertion, number of polyps removed upon insertion, number of polyps removed upon withdrawal, overall technical ease (score from 1 to 4 where 1 stands for no technical problems, 2 for minor, 3 for moderate, and 4 for major technical difficulties), presence of technical problems (difficult visualization of the polyps, difficult removal of polyps, and difficult retrieval of polyps, all answered categorically with "Yes" or "No"), patient tolerance (completed by patients), and characterization of every polyp (location, size, time of removal and additional comments).


Recruitment information / eligibility

Status Completed
Enrollment 400
Est. completion date April 2007
Est. primary completion date March 2007
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Need for a complete colonoscopy

- 18 years of age and older

Exclusion Criteria:

- Need for urgent colonoscopy due to bleeding

- High likelihood of colonic stenosis or severe inflammation

- Known inflammatory bowel disease (IBD)

- Known familiarity adenomatous polyposis (FAP)

- Contraindications for polypectomy such as coagulopathy, use of anti-clotting medication (anticoagulation, aspirin, NSAIDs)

- Missing signed consent

Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Prevention


Related Conditions & MeSH terms


Intervention

Procedure:
Polyp removal upon insertion and withdrawal
Endoscopic procedures: All polypectomies in the study groups were performed using the same techniques as in the standard care of non-study patients, using snare loops, hot biopsy forceps, with and without submucosal injection of saline/epinephrine. Polyps larger than 3 mm were removed by snare, polyps smaller than 4 mm were removed by cold biopsy. There were no differences upon insertion or withdrawal. The endoscopist removed all visible polyps instantly regardless whether advancing the instrument to the cecum or pulling back.
Polyp removal upon withdrawal only
Endoscopic procedures: All polypectomies in the study groups were performed using the same techniques as in the standard care of non-study patients, using snare loops, hot biopsy forceps, with and without submucosal injection of saline/epinephrine. Polyps larger than 3 mm were removed by snare, polyps smaller than 4 mm were removed by cold biopsy. There were no differences upon insertion or withdrawal. The endoscopist advanced the endoscope to the cecum without removing polyps. Upon withdrawal, all visible polyps were removed successively by standard techniques.

Locations

Country Name City State
Switzerland University of Zürich Zürich

Sponsors (1)

Lead Sponsor Collaborator
University of Zurich

Country where clinical trial is conducted

Switzerland, 

Outcome

Type Measure Description Time frame Safety issue
Primary Polyp detection 2004 - 2007 Yes
See also
  Status Clinical Trial Phase
Completed NCT02595775 - A Trial of an Audit and Feedback Report to Improve Colonoscopy Performance N/A
Completed NCT01950117 - Complete Removal of Neoplastic Large Colorectal Polyps: a Prospective Randomized Comparison of Endoscopic Mucosal Resection or Conventional Polypectomy N/A
Completed NCT01486745 - Urine Metabolomics and Colorectal Cancer Screening
Completed NCT02284802 - Early Detection of Tumors of the Digestive Tract by Confocal Endomicroscopy N/A
Completed NCT04727918 - Comparison of Cold Biopsy Forceps vs Cold Snare for Diminutive Colorectal Polyp Removal N/A
Completed NCT00298545 - Effect of Vitamin D and Calcium on Genes in the Colon Phase 1
Completed NCT01262248 - Computer-based Classification of Colorectal Polyps Using Narrow-band Imaging N/A
Completed NCT00988676 - The Effect of Bowel Preparation Status on the Polyp Missing Rate N/A
Recruiting NCT03787784 - Automatic Classification of Colorectal Polyps Using Probe-based Endomicroscopy With Artificial Intelligence N/A
Completed NCT00622557 - General Surgical Outcomes Quality Improvement Database (UH-SOCRATES)
Completed NCT01553565 - Prospective Comparison of Cold Polypectomy and Conventional Polypectomy for Small Colorectal Polyps in Patients Taking Antithrombotic Agents N/A
Active, not recruiting NCT03699163 - The Colorectal Breath Analysis (COBRA) Study
Completed NCT01633333 - Water Exchange Versus Carbon Dioxide for Colonoscopy N/A
Recruiting NCT03620695 - Confocal Laser Endomicroscopy With Topical Cresyl Violet for Colorectal Polyps
Completed NCT00204867 - Virtual Colonoscopy (VC) for Primary Colorectal Screening N/A
Active, not recruiting NCT02887573 - Free-residue Nutrients for the Bowel Preparation of Colon Capsule Endoscopy Phase 4
Not yet recruiting NCT02033980 - Efficacy of NICE Classification in the Histological Evaluation of Colorectal Lesions N/A
Completed NCT02217449 - Virtual Chromoendoscopy for Distal Polyps
Completed NCT00725465 - Prospective Evaluation of Combined Laparoscopy With CO2 Intraoperative Colonoscopy Treatment for Colorectal Lesions
Completed NCT02354287 - Effectiveness of Cold Biopsy Forceps With Pre-lift for Complete Resection of Colonic Polyps ≤7mm in Size N/A