Colonic Polyps Clinical Trial
Official title:
Detect InSpect ChAracterise Resect and Discard 2
Bowel cancer is a common disorder in the UK. Most cancers happen when a type of polyp,
called an adenoma, becomes cancerous. Polyps are growths in the large bowel that can be
cancerous, non-cancerous, or pre-cancerous (adenoma). Polyps are most commonly detected
during colonoscopy (camera test of the lower bowel). The removal of adenomas has been shown
to reduce the subsequent risk of bowel cancer. Current practice is that all polyps are
removed or biopsied to allow a laboratory diagnosis (histology). This is important as it
influences if and when patients require follow-up colonoscopies, known as the surveillance
interval. Patients with only non-cancerous polyps do not need surveillance.
A new blue light technology, called narrow band imaging (NBI), used during colonoscopy can
help colonoscopists (doctor or nurse performing the procedure)differentiate between polyp
types during colonoscopy. NBI is currently available in a large number of UK endoscopy units
however is variably used. Studies from 'expert' centres have demonstrated that NBI allows
accurate optical diagnosis of colonic polyps. Benefits of optical diagnosis include avoiding
removal of non-cancerous polyps and an immediate (on the day) diagnosis for the patient
including the surveillance interval.
The primary aim of this study is to evaluate the accuracy with which colonoscopists assess
the required surveillance interval using optical diagnosis when compared with histology in
non-expert centres. The investigators will invite 2500 patients, who have been referred for
colonoscopy, to participate. Patients will undergo a routine colonoscopy the only addition
being the use of NBI during the procedure. Colonoscopists will provide an optical diagnosis
at the time of colonoscopy in addition to polyp removal or biopsy.
The investigators will compare surveillance intervals provided using optical diagnosis with
the diagnosis from histology and thereby the accuracy with which colonoscopists can use the
technology. The investigators will also calculate the cost savings to the NHS.
Colorectal cancer (CRC) continues to be a major problem in the UK and is the second most
common cause of cancer death. The annual incidence is approximately 30,000 cases with an
annual mortality rate of in the region of 16,000 (1). Most sporadic non-hereditary CRCs
arise from benign colorectal adenomas (2). The detection and resection of colorectal
adenomas at colonoscopy has been shown to reduce the subsequent risk of CRC by as much as
80% (3).
The NHS Bowel Cancer Screening Programme (BCSP) began roll-out in 2006 in England and as of
April 2010, was established across 99.4% of the country. The BCSP is based on a strategy of
biennial faecal occult blood test (FOBt) screening for men and women aged 60-75, followed by
colonoscopy for those who test positive. Among its aims is the detection and resection of
potentially pre-malignant colorectal adenomas thereby potentially reducing the incidence of
CRC. The introduction of the BCSP has resulted in a dramatically increased demand for
colonoscopy. To date approximately 80,000 colonoscopies have been performed within the BCSP
and at least one adenoma found in just under half of the procedures (4). In addition, from
2012, the BCSP will introduce flexible sigmoidoscopy screening for all individuals aged 55
yr olds. This extrapolates to approximately 500,000 flexible sigmoidoscopies per year, with
at least one polyp expected to be found in 75,000 procedures.
Greater than 90% of polyps detected at colonoscopy are small (6-9mm) or diminutive (≤5mm),
with the latter making up the majority (5-7). In addition, approximately 50% of small polyps
are non-neoplastic (8), known as adenomas. The number of adenomas present strongly
influences the future risk of the development of advance neoplasia for the individual
patient and therefore determines decisions on future surveillance intervals. As a result
even small polyps, with little risk of harbouring cancer, are currently sent for
histological assessment in order to determine whether or not they are adenomatous (9-11).
The ability to correctly diagnose a small polyp (< 10mm) during colonoscopy as adenomatous
or non-adenomatous from its endoscopic characteristics (optical diagnosis) would allow small
adenomas to be resected and discarded without the need to retrieve the polyp for formal
histological assessment. Additionally, hyperplastic rectosigmoid polyps can be left in situ
thereby reducing the need for polypectomy and the associated risks. Optical diagnosis would
also enable surveillance intervals to be determined immediately after colonoscopy thereby
avoiding the need for out-patient follow up, potentially leading to significant time and
cost savings. Notably, histological assessment is an imperfect current gold standard as
polyps may be lost or be unable to be assessed due to diathermy artefact in 8-25% of cases.
Furthermore, standard histological techniques may misclassify up to 15% of adenomas as
benign lesions.
Narrow band imaging (NBI; Olympus, Japan (12, 13)) is a new 'blue light' optical imaging
modality available at a push of a button on the colonoscope head. By enhancing mucosal
detail and in particular vascular structures it allows assessment of microvascular density
(vascular pattern intensity - VPI (14); meshed brown capillary network (15-17)). Neoplastic
tissue is characterized by increased angiogenesis and, therefore, adenomas appear darker
when viewed with NBI. The use of microvascular assessment appears to have a short learning
curve, as short as 60 histologically verified polyps (18-20), making it a potentially
attractive and practical option for optical diagnosis. There are no known adverse events
associated with NBI.
Two studies to date have assessed clinical implications of endoscopic diagnosis of small
polyps on surveillance intervals using white light in combination with NBI. A study of
diminutive polyps (≤5 mm) performed by a single expert colonoscopist (21), 134 out of 136
(98.5%) of patients would have had the same surveillance intervals when recommendations
based on optical and histological diagnoses were compared. Similar results were reported in
a study performed by three of the co-applicants (AI, JEE, BPS)(22) where 82 out of 130
patients could be given a surveillance interval immediately after colonoscopy based on
optical diagnosis alone and the same interval was found after formal histopathology in 80
patients (98%) using British Society of Gastroenterology guidelines (23). Optical diagnosis
accurately diagnosed 186 of 198 adenomas (sensitivity 0.94; 95% CI 0.90-0.97) and 55 of 62
hyperplastic polyps (specificity 0.89; 0.78 -0.95) with an overall accuracy of 241 of 260
(0.93; 0.89-0.96) for small polyp characterisation. In this study, using simple cost
analysis, the authors estimated that optical diagnosis would have resulted in 77% cost
savings for polyp analysis and clinical follow up (£13343 for 130 patients examined). Using
Markov modelling, Hassan et al modelled the cost-effectiveness of 'resect and discard
policy' and found that using it for diminutive polyps (≤5mm) would result in annual saving
of $33 million when applied to colonoscopy screening of the US population (corresponding to
overall saving of $330 million, assuming cumulative period of 10 years to screen just under
a quarter of US population) (24).
Optical diagnosis may therefore benefit:
1. Patients: Shorter, more accurate examinations with fewer complications as a results of
fewer polypectomies (less perforation and bleeding), reduced anxiety (awaiting
histology results) and more appropriate use of endoscopic surveillance programmes.
2. NHS and other Healthcare providers: Increased efficiency (shorter lists, more exams per
endoscopy list, fewer out-patient appointments, avoids unnecessary use of histology
capacity) and reduced risk (fewer complications and fewer polyp 'misses'). Since the
need for histology is set to greatly increase with an expansion of screening, a move to
the routine use of NBI may substantially reduce the need to expand histology services.
We foresee no significant constraints to adoption of optical diagnosis as financial costs
should be easily offset by savings from the efficiency benefits described above as 90% of
polyps detected at colonoscopy are <10mm in size and therefore suitable for optical biopsy.
Study Design DISCARD 2 is a blinded calibration diagnostic study which will compare NBI
optical diagnosis with histological assessment (as a reference standard) for patients with
small polyps (<10mm) identified at colonoscopy
Recruitment Patients who are due to attend for a routine colonoscopy will be identified
during out-patient clinics, during colonoscopy booking, or on the day of colonoscopy at each
of the participating sites. Patients will be sent or given an information pack containing an
information sheet and consent form. There will be two phases of recruitment to the study.
All consenting patients undergoing colonoscopy are included in phase 1 of the study. Those
who undergo a complete colonoscopy and in whom one or polyp <10mm in diameter is found will
enter phase 2 of the study.
More detail regarding inclusion and exclusion criteria and outcome measures are provided
below.
;
Observational Model: Cohort, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05615857 -
Endocuff Enhanced Colonoscopy: Does it Improve Polyp Detection and Make Rectal Retroflexion Unnecessary
|
N/A | |
Not yet recruiting |
NCT02865382 -
Detection of Colorectal Adenoma by Optical Enhancement Technology vs. High-Definition Colonoscopy
|
N/A | |
Completed |
NCT02529007 -
Endo-cuff Assisted Vs. Standard Colonoscopy for Polyp Detection in Bowel Cancer Screening
|
N/A | |
Completed |
NCT02245854 -
Efficacy and Safety of a New Polypectomy Snare for Cold-polypectomy for Small Colorectal Polyps
|
N/A | |
Completed |
NCT01712048 -
Submucosal Injection EMR vs. Underwater EMR for Colorectal Polyps
|
N/A | |
Terminated |
NCT01297712 -
Endoscopic Assessment of Polyp Histology
|
N/A | |
Active, not recruiting |
NCT01368289 -
Australian Multicentre Colonic Endoscopic Mucosal Resection Study
|
||
Completed |
NCT02196649 -
Clip Placement Following Endoscopic Mucosal Resection - Randomised Trial
|
N/A | |
Completed |
NCT00997802 -
Japanese National Computed Tomographic (CT) Colonography Trial
|
N/A | |
Not yet recruiting |
NCT00996619 -
Measuring the Spectrum of Tissues During Endoscopy
|
N/A | |
Completed |
NCT00468455 -
Post-Op Quality of Life After Colorectal Surgery
|
N/A | |
Completed |
NCT00018551 -
Chemoprevention With Folic Acid
|
Phase 2 | |
Recruiting |
NCT02552017 -
Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities
|
N/A | |
Completed |
NCT01979458 -
Photometric Stereo Endoscopy (PSE) as a Tool for Imaging the Rectum and Colon
|
N/A | |
Unknown status |
NCT01101672 -
Trial for Single Port Versus Conventional Laparoscopic Colectomy
|
Phase 2/Phase 3 | |
Terminated |
NCT01458925 -
Feasibility of Check-Cap's P1 Capsule System Screening
|
N/A | |
Recruiting |
NCT05737017 -
The Efficacy and Safety of a Hybrid Hemostatic Device (ClearCoajet)
|
N/A | |
Recruiting |
NCT02760381 -
Acetic Acid for Optical Characterization of Colonic Polyps
|
N/A | |
Withdrawn |
NCT04253990 -
Efficacy and Safety of Precut-EMR for Resecting of Colonic Polyp
|
N/A | |
Completed |
NCT01901510 -
Panchromoendoscopy Using Oral Indigo Carmine Mixed With Polyethylene Glycol Prep
|
Phase 1 |