Clinical Trial Summary

Colonoscopy is considered the gold standard for colorectal polyp and cancer detection. However, even meticulous colonoscopy substantial numbers of colorectal polyps may be missed and carcinomas may not be prevented. Previous studies have found a 12-28% of miss rate for all polyps, a 31% for hyperplastic polyps and 6-27% for adenomas, with the higher miss rates noted for smaller polyps. The lesions missing rate depends on several factors as the location on difficult areas to be evaluated with conventional colonoscopes (the proximal side of the ileocecal valve, haustral folds, flexures or rectal valves), a flat shape, a poor bowel preparation and inadequate endoscopy technique, particularly rapid colonoscope withdrawal. Using the commonly available 140º angle of view colonoscope, approximately 13% of the colonic surface is unseen. The incorporation of colonoscopes with a 170-degree wide angled could not improve adenoma detection rate. The introduction of high definition (HD) colonoscopes and visual image enhancement technologies as narrow band imaging (NBI, Olympus America, Center Valley, PA), i-SCAN™ (PENTAX of America, Montvale, NJ) and Fuji Intelligent Chromo-Endoscopy (FICE™, Fujinon Endoscopy, Wayne, NJ) have improved the lesion characterization, but several studies proved no increase in adenoma detection rates. The Third Eye Retroscope (Avantis Medical Systems, Sunnyvale, CA) is a disposable retrograde viewing device advanced via the accessory channel of a standard colonoscope. Allows retrograde views behind colonic folds and flexures simultaneously with the forward view of the colon. Although it was shown an increase in adenoma detection rate by 11%-25%, it has many disadvantages. It requires a separate processor and the device is disposable making the cost bigger. Occupies the working channel of the colonoscope which limits the ability to suction. If a polyp is seen the viewing device has to be removed in order to perform the polypectomy. The optic is not high definition and finally, the endoscopist has to get used to visualizing and processing two simultaneous video streams from the colonoscope and from the retroscope device.


Clinical Trial Description

The Retroview™ (PENTAX Medical, HOYA Co.) colonoscope has a short turning radius at the colonoscope tip, that allows a retroflexed view of the colon during withdrawal. This may allow for detection of polyps hidden behind flexures, folds and valves, from the cecum to the rectum. It offers many advantages like the ability to provide high definition views of the proximal aspects of colonic folds, flexures and valves with no additional equipment or device costs. The image is high definition and the colonoscope also incorporates i-SCAN technology. The suction/work channel of the colonoscope is available for therapeutic procedures. Polypectomy can be performed with the colonoscope in retroflexion, without losing views of the polyp. The only disadvantages are the higher consumed withdrawal time because the additional retroflexed withdrawal to the standard withdrawal and that a small portion of the colon is obscured by the shaft of the colonoscope in retroflexion that may be the reason why combined standard withdrawal with retroflexed withdrawal has proved to be better than retroflexed withdrawal alone.

The aim of this study is to determinate and compare the polyp / adenoma detection rate and lesion miss rate by performing a colonoscopy using conventional scopes vs PENTAX RetroView™ scope. As a secondary outcome, size of lesions will be measure in order to determinate if there is a difference between both technics.

MATERIALS AND METHODS

Setting: Instituto Ecuatoriano de Enfermedades Digestivas (IECED), Omni Hospital Academic Tertiary Center. We will include patients from December 2016 to July 2017. The study protocol and consent form has been approved by the Institutional Review Board and will be conducted according to the declaration of Helsinki. Patients will sign an informed consent.

Intervention: endoscopic technique The colonoscopy will be performed, in all cases, twice with 2 different scopes. One is a conventional HD colonoscope with I-Scan, tube diameter of 13.2 mm and total length 2023 mm (standard EC 3490LK, PENTAX, Montvale, NJ) and the other is the Retroview™ colonoscope with tube diameter of 11.6 mm and total length 2023 mm (EC-3490TLi, PENTAX, Montvale, NJ). The endoscopy images will be seen on a 27-inch, flat panel, HD LCD monitor (Radiance™ ultra SC-WU27-G1520 model). All of the participants will follow the same colonic preparation with 4 liters of polyethylene glycol (PEG) the day before and the bowel preparation will be evaluated using the Boston Bowel Preparation Scale. Two trained endoscopists on retroflex withdrawal will perform the colonoscopies. Both colonoscopies will be performed in tandem. First one endoscopist will perform the conventional colonoscopy using standard withdrawal technique and then the second endoscopist blinded to the first colonoscopy results, will perform the second colonoscopy with the Retroview scope and combination withdrawal (retroflexed + standard withdrawal). The endoscopist that will perform each colonoscopy will be chosen randomly. The minimum withdrawal time of 6 minutes that is recommended in literature will be respected in both cases. After the examination, the endoscopist will fill a questionnaire detailing each polyp / adenoma found including the size and location. The withdrawal time will be measured in both colonoscopies.

Statistical analysis: Baseline characteristics will be analyzed using Chi-square o Fisher Test for categorical variable and Mann-Whitney Test for continuing variables. If there are more than one polyp in one patients it will be considered individually for statistical purposes. A P value of less than 0.05 will be considered to be statistically significant. All the statistical analysis will be performed using SPSS software suite v.22.

Limitations: The protocol will be performed in only one center and by two endoscopists. There is no control group because the intention is to compare two endoscopy methods in the same setting. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03155165
Study type Observational
Source Instituto Ecuatoriano de Enfermedades Digestivas
Contact
Status Completed
Phase
Start date May 1, 2017
Completion date August 31, 2017

See also
  Status Clinical Trial Phase
Terminated NCT03746353 - Early Closure Versus Conventional Closure in Postoperative Patients With Low Anteriresection for Rectal Cancer N/A
Recruiting NCT05809999 - IBD Neoplasia Surveillance RCT N/A
Recruiting NCT06041945 - Artificial Intelligence to Implement Cost-saving Strategies for Colonoscopy Screening Based on in Vivo Prediction of Polyp Histology N/A
Not yet recruiting NCT02688699 - Additive Hemostatic Efficacy of EndoClot After EMR or ESD in the Gastrointestinal Tract Phase 4
Not yet recruiting NCT03175146 - A Study to See Whether Stereotactic Body RadioTherapy (SBRT) Can Shrink Tumours Within the Liver Safely N/A
Completed NCT02529007 - Endo-cuff Assisted Vs. Standard Colonoscopy for Polyp Detection in Bowel Cancer Screening N/A
Not yet recruiting NCT01929499 - Efficacy of Adjuvant Cytokine-induced Killer Cells in Colon Cancer Phase 2
Completed NCT01681472 - PK/PD Investigation of Modufolin (Arfolitixorin) in Plasma, Tumor and Adjacent Mucosa Adjacent Mucosa in Patients With Colon Cancer Phase 1/Phase 2
Completed NCT01438645 - ScopeGuide-assisted Colonoscopy Versus Conventional Colonoscopy N/A
Completed NCT00535652 - Concentration of Ertapenem in Colorectal Tissue Phase 4
Terminated NCT00267787 - Molecular Genetic and Pathological Studies of Anal Tumors
Completed NCT05498051 - Fluorescent Sentinel Lymph Node Identification in Colon Carcinoma Using Submucosal Bevacizumab-800CW. N/A
Recruiting NCT05068180 - Low-dose Neuroleptanalgesia for Postoperative Delirium in Elderly Patients Phase 4
Recruiting NCT03314896 - Laparoscopic Surgery for T4 Tumor of the Colon Cancer (LST4C Trial) N/A
Not yet recruiting NCT02852915 - Laparoscopic Surgery for T4 Tumor of the Colon Cancer Phase 3
Not yet recruiting NCT02777437 - Laparoscopic Surgery VS Laparoscopic Surgery + Neoadjuvant Chemotherapy for T4 Tumor of the Colon Cancer Phase 2/Phase 3
Completed NCT00997802 - Japanese National Computed Tomographic (CT) Colonography Trial N/A
Completed NCT01056913 - NITI CAR27 (ColonRing) Compression Anastomosis in Colorectal Surgery Phase 4
Completed NCT00537901 - First-Line Bevacizumab and Chemotherapy in Metastatic Cancer of the Colon or Rectum - International Study N/A
Completed NCT00470782 - Aerobic Capacity and Body Composition in Colon Cancer Patients N/A