Colo-rectal Cancer Clinical Trial
Official title:
Understanding Patient Preference on Colorectal Cancer Screening Options
There are significant barriers to colorectal cancer screening within underserved populations due to the cost, accessibility, and acceptability of screening methods. Patient-friendly approaches that minimize stress and discomfort for the patient are needed to enhance screening compliance and achieve an early diagnosis. The primary aim of this study is to examine whether the availability of a blood-based screening option, which can be done at the point of service and is familiar to patients, will improve patient compliance to recommended CRC screening
Scientific Background and Gaps Colorectal cancer (CRC) is the third most common cancer type and the second leading cause of cancer death in the United States. The lethal nature of CRC is attributable to its being largely asymptomatic during the early stages and the lack of curative treatment options for patients with progressive disease. Early detection by screening significantly reduces mortality from CRC; however, many people are not up to date with screening, with overall screening rates under 70%. Furthermore, about a quarter of age-eligible adults (27.1 million) have never been screened for CRC. A recent study found that not being up to date with screening was associated with an approximate 3-fold risk for CRC-related mortality. Despite many years of effort and funding support, CRC screening rates have plateaued, with a considerable segment of the population remaining unscreened. The percentage of age-eligible adults who were up to date with CRC screening only increased by 1.4% (4.2 million) from 67.4% in 2016 to 68.8% in 2018. Compliance with CRC screening is particularly poor among medically underserved populations, including those with low income and racial/ethnic minority populations. There are significant barriers to screening within underserved populations due to the cost, accessibility, and acceptability of screening methods. To date, there are many well-established CRC screening modalities and can include invasive and non-invasive options that detect both polyps and cancer or cancer alone. Colonoscopy is considered the gold standard for CRC screening and remains the dominant screening modality in the U.S. However, due to the invasiveness, perception of discomfort and embarrassment, logistical challenges (e.g., lack of transportation, time off of work), cost, and potential risks, the uptake of colonoscopy is low. For patients unwilling to screen with colonoscopy, non-invasive stool-based testing can shift CRC detection to earlier and more curable stages. However, the compliance of stool-based testing is suboptimal due to the cultural stigma surrounding sample collection techniques and the inconvenience of returning the kit for testing. Increasing patient compliance and adherence to screening is critical to improving CRC outcomes. Patient-friendly approaches that minimize stress and discomfort for the patient are needed to enhance screening compliance and achieve an early diagnosis. A blood-based screening option can improve CRC screening uptake and adherence at FQHCs, and, ultimately, eliminate unnecessary cancer disparities. Previous Data Patient compliance is a major barrier to achieving universal screening. Blood-based testing can offer an alternative for patients who fail to comply with other screening modalities. Blood tests are non-invasive compared to colonoscopy, and individuals are more willing to have a blood test than take a stool sample at home. In a cross-sectional survey of 100 individuals, 91% ranked a blood-based test as their first or second choice of screening (58% for the first choice, 10% tied, and 23% for the second choice) compared with colonoscopy, sigmoidoscopy, or stool-based tests. Furthermore, over two-thirds of minority respondents (n=62) chose a blood-based screening test as their first choice for future screening. Blood-based screening test also presents an opportunity to overcome challenging barriers, such as transportation and time off from work, limiting screening participation. Study Rationale A key to improving screening participation is patient acceptance of the testing method. Indeed, all the screening modalities have benefits over time, and compliance to testing is essential for successful screening. A blood-based screening test can easily be part of a routine clinic visit and the patient can complete the test while is still at the clinic. Patients are accustomed to providing blood samples for other screening tests, such as cholesterol screening and the use of blood-based CRC screening test is likely more in line with a patient's expectations of medical care. On January 19, 2021, the Centers for Medicare and Medicaid Services announced that the blood-based biomarker test is an appropriate CRC screening once every 3 years for Medicare patients when performed in a CLIA-certified laboratory, ordered by a treating physician, and the blood-based biomarker screening test has a sensitivity greater than or equal to 74% and a specificity greater than or equal to 90% in the detection of CRC. The last decades have seen many discovery studies identifying promising biomarkers of CRC. Improving testing methods for blood-based CRC testing have been developed and implemented in clinical settings as well. The first blood-based CRC screening test, SEPT9 DNA (Epi proColon), was approved by the FDA in 2016 for persons at average risk for CRC who have chosen not to undergo screening by existing guideline-recommended methods. This study will offer a lab-developed Guardant SHIELD blood-based CRC screening test to patients who failed to complete a stool-based screening test or a colonoscopy six months after receiving an order from their providers. The Guardant SHIELD blood-based screening test will be free to the patients with an order from their providers. The Guardant SHIELD test is a multimodal blood-based colorectal neoplasia detection assay incorporating ctDNA (circulating tumor DNA) assessment of somatic mutations and tumor-derived methylation and fragmentomic patterns to maximize early-stage CRC detection sensitivity. Overall, the Guardant SHIELD blood-based test has a CRC sensitivity of 91% and a specificity of 94%, meeting the Centers for Medicare and Medicaid Services requirement (74% for sensitivity and 90% for specificity). All the blood samples collected in this study will be processed at the CLIA-certified Guardant Health Laboratory. Compliance by age-eligible patients is essential to the success of any screening program. However, the acceptance by health care providers and the health care system is also critical, and especially colonoscopy remains the dominant modality for CRC in the U.S. Applying the current state of research evidence to health care involves fostering the adoption, implementation, spread, and sustainability of new evidence-based interventions to care. Furthermore, transferring effective interventions into real-world settings and maintaining them is a complicated, long-term process that requires complex phases of intervention diffusion. In this study, we will examine the inclusion of a blood-based screening option to increase patient compliance with CRC screening while developing implementation strategies to facilitate the adoption of a new blood-based screening test at primary care clinics. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05074966 -
The Efficacy and Safety of Modified XELOX(mXELOX) Plus Cetuximab vs FOLFOX Plus Cetuximab in RAS and BRAF WT mCRC Pts
|
Phase 3 | |
Active, not recruiting |
NCT03667716 -
COM701 (an Inhibitor of PVRIG) in Subjects With Advanced Solid Tumors.
|
Phase 1 | |
Suspended |
NCT05124743 -
HLA Typing & Tumor Neoantigen Identification for Phase I/II Study of Autologous TCR-T Cells in Subjects With Solid Tumors
|
||
Recruiting |
NCT05056389 -
Normothermic Intraperitoneal Chemotherapy - Long Term in Peritoneal Metastases From Colorectal Cancer (NIPEC-OXA)
|
Phase 1 | |
Completed |
NCT04551014 -
Evaluation of EverLift in the Performance of Polypectomy for Polyps 4-9mm
|
N/A | |
Completed |
NCT04551001 -
Evaluation of Cold Forcep and Cold Snare Polypectomy for Polyps Less Than or Equal to 3mm in Size During Colonoscopy
|
N/A | |
Recruiting |
NCT04270500 -
The Impact of Physical Exercise on Sleep in Colorectal Cancer Patients During Prehabilitation Period
|
N/A | |
Recruiting |
NCT03667911 -
Virtual Reality Videos in Improving Bowel Preparation Quality of Colonoscopy
|
N/A | |
Not yet recruiting |
NCT04073680 -
A Phase 1b/2 Study of Serabelisib in Combination With Canagliflozin in Patients With Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Recruiting |
NCT05572684 -
A Safety, Tolerability and Efficacy Study of NC410 Plus Pembrolizumab in Participants With Advanced Unresectable or Metastatic Solid Tumors
|
Phase 1/Phase 2 | |
Suspended |
NCT04108481 -
Immunotherapy With Y90-RadioEmbolization for Metastatic Colorectal Cancer
|
Phase 1/Phase 2 | |
Completed |
NCT03567850 -
Problem Solving Skills Training in Adult Cancer Survivors: Bright IDEAS-AC
|
N/A | |
Recruiting |
NCT05870332 -
Nationwide Study of Artificial Intelligence in Adenoma Detection for Colonoscopy
|
||
Completed |
NCT04534218 -
Regorafenib in Combination With Metronomic Chemotherapies, and Low-dose Aspirin in Metastatic Colorectal Cancer
|
Phase 2 | |
Enrolling by invitation |
NCT05590117 -
Protective Effect of Pentoxifylline Against Chemotherapy Induced Toxicities in Patients With Colorectal Cancer
|
Early Phase 1 | |
Recruiting |
NCT03129139 -
A Phase 1, Multi-Center, Open-Label, Dose-Escalation, Safety, Pharmacokinetic, and Pharmacodynamic Study of Minnelideā¢ Capsules Given Alone or in Combination With Protein-Bound Paclitaxel in Patients With Advanced Solid Tumors
|
Phase 1 | |
Completed |
NCT04195646 -
Computer Aided Detection of Polyps During Colonoscopy Procedures
|
N/A | |
Not yet recruiting |
NCT03261752 -
New Genes in the Carcinogenesis of Colorectal Cancer
|
||
Not yet recruiting |
NCT03618329 -
Effect of Prehabilitation on the Lean Mass Index (IMM) in ERAS PROGRAMM.
|
N/A | |
Terminated |
NCT03621982 -
Study of ADCT-301 in Patients With Selected Advanced Solid Tumors
|
Phase 1 |