Clinical Trials Logo

Clinical Trial Summary

This study aims to assess the effect of PRP on the rate and type of OTM during en-masse frictionless retraction of maxillary anterior teeth using a segmental arch technique. Thirty adult patients exhibiting class II division 1 malocclusion requiring upper first premolar extractions followed by en-masse retraction will participate in the study. They will be randomly and equally distributed into the PRP group (G1) and the control group (G2). The injection of PRP will be performed pre-retraction. The rate of orthodontic tooth movement will be assessed clinically by measuring the extraction space with a digital caliper. The cephalometric radiographs will evaluate the type of OTM at the beginning of en-masse retraction (T0) and at the middle of en-masse retraction (T1).


Clinical Trial Description

One of the most important challenges in daily practice is prolonged orthodontic treatment duration. Many therapeutic procedures, such as chemical interventions, have been introduced to minimize orthodontic treatment time. Even though all the methods of chemically assisted acceleration of OTM increase the rate of bone turnover and increase the rate of tooth movement, however, these chemical agents, i.e., hormones or vitamin D3, have many problems such as systemic effects and short half-life which make them not practical in clinical orthodontic. Therefore, the injection of PRP has been proposed. -In both groups, two first upper premolars were extracted. In all patients, fixed metal orthodontic brackets with MBT prescription 0.022 were bonded. After the arches were leveled and aligned, a rigid sectional archwire (0.021 x 0.025 in stainless steel) was used for the anterior six teeth. To strengthen anchorage, microscrews (diameter 1.6 mm; length 10 mm) were inserted at 8mm from the archwire into the inter-radicular space between the maxillary first molar and second premolar. Two crimpable hooks were used with a height of 8 mm between the lateral incisor and canine on both sides of the sectional wire 0.021x0.025 to pass the force vector as close as possible to the center of resistance. En-masse retraction began one week after premolar extraction, using calibrated nickel-titanium coil springs with 175 g force per side. -In PRP, 48 ml of blood was collected from the patient in sterile tubes with ACD-A as an anticoagulant. PRP was prepared as follows: Initially, the blood was centrifuged at 2000 rpm for 6 minutes. After separation of the blood, PRP and some Platelet-Poor Plasma (PPP) were collected and mixed in a dry tube, and then a second centrifugation was done at 2700 rpm for 3 minutes. After the second centrifugation, the lower 1/3rd of the tube is PRP. About 4 ml of PRP was collected from the tube, and then the patient was injected with it. After regional anesthesia for pain control, 0.5 ml of PRP was slowly injected submucosally palatal to each tooth from the right canine to the left canine using a 1cc syringe. Paracetamol was described for the patient to control pain and ensure confirming not to use ibuprofen or another NSAIDS. The injection was applied one time. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06133361
Study type Interventional
Source Damascus University
Contact
Status Completed
Phase N/A
Start date February 24, 2019
Completion date December 15, 2021

See also
  Status Clinical Trial Phase
Completed NCT04619446 - Dentoskeletal Changes Produced by Growth Modification Appliances in Treatment of Skeletal Class II Malocclusion
Active, not recruiting NCT05171738 - Distalization Via Skeletally-anchored Distaljet Appliance With Two Approaches of Micro-osteoperforations N/A
Completed NCT00248014 - Response of Individuals With Class II Malocclusion Phase 2
Completed NCT01853995 - Mechanism of Class II Correction With Fixed Lingual Mandibular Growth Modificator (FLMGM) Phase 2
Completed NCT01853137 - Fixed Lingual Mandibular Growth Modificator N/A
Completed NCT04814173 - The Efficacy of Tow Mechanics for Total-maxillary-arch-distalization N/A
Recruiting NCT03839303 - Comparison Between Mini Implant Supported Appliance and Headgear in Treatment of Maxillary Excess in Growing Patients N/A
Completed NCT04847492 - Evaluation of Upper Anterior Teeth Retraction Rate Assisted by Two Corticotomy Techniques N/A
Recruiting NCT04810286 - Prefabricated Versus 3D-Printing Myofunctional Appliances N/A
Not yet recruiting NCT03764189 - Evaluation of Micro-osteoperforation on Rate of Maxillary En-masse Retraction N/A
Terminated NCT00957489 - A Prospective Randomized Controlled Trial to Evaluate the Effectiveness of the Two Different Appliances in the Treatment of Class II Division 1 Malocclusion N/A
Recruiting NCT04743258 - Bilateral Premolar Extraction vs Distalization: A Randomised Clinical Trial N/A
Active, not recruiting NCT04191070 - Distalization Using Infrazygomatic Crest Miniscrews and Zygomatic Miniplates: A Randomized Clinical Trial N/A
Completed NCT05335824 - The Effect of Autologous Platelet Concentrations on Orthodontic Treatment Time N/A
Completed NCT05542745 - Measuring Rate of Anteriors Retraction With Two Different Techniques N/A
Completed NCT05040945 - Evaluation of the Levels of Pain and Discomfort Associated With Two Techniques of Corticotomy N/A
Completed NCT05928143 - Patient Outcomes Associated With Two Accelerated Method of Retraction of Upper Front Teeth N/A
Completed NCT04316403 - Laser-assisted Flapless Corticotomy in Accelerating Canine Retraction N/A
Not yet recruiting NCT03635463 - Effect of Modified Twin Block in Skeletal Class II Growing Females With Mandibular Deficiency N/A
Completed NCT03467555 - Evaluation of Distal Movement of Maxillary Dentition With Zygomatic Miniplates Using Cone Beam Computed Tomography N/A