Child Clinical Trial
Official title:
Optimization of Cochlear Implant MAP-parameters in Children, Reprogramming Based on Active Co-operation
This project will complete a long-term follow up for children that have received cochlear implants (CI) early in life and had their CI's programmed based on objective measurements. At Sahlgrenska University Hospital in Gothenburg, generally, all younger children (0-3 years), the last ten years, had their CI's programmed based on objective measurements. The programming of the CI carried out during the first year after the surgical insertion is done on the foundation of the objective measurements and is generally what the child will live with thereafter. This method also seem to be close to other clinics in Sweden and the rest of the world, however, there are no specific guidelines regarding the how the programming of the CI is to be carried out on small children. To this date there are no studies, to our knowledge, that have confirmed the validity of using these objective measurements and if it is the best for the child. We therefore aim to do a long term follow up on children that have received CI and programmed this way, and study if there would be beneficial to redo the programming when the child is old enough to actively participate. The aim with this project is evaluate how suitable it is to mainly use objective measurements when programming the cochlear implant and, in addition to this, examine if the children's hearing can be improved if the programming is based on the behavioral measurements of sound when the children are old enough to participate in such. It will examine what happens with the end result if the programming foundation differentiates from one another; if there are any measurable differences in hearing skills. The result from this project expects to generate knowledge that is highly important for those working with small children receiving CI's, and by extension it will benefit the children that rely on this device in there every day life.
Cochlear implants (CI) enable hearing for persons who otherwise would have been deaf. A CI substitutes the sensory cells in the cochlea and stimulates the auditory nerve directly with weak electrical pulses. For children born deaf, or become deaf at an early age, prompt detection of this condition is important to since it enables the possibility of an early implantation of the CI and facilitates the child's development of a spoken language. When it comes to detecting deafness in newborns, Sweden has a well-functioning and widespread hearing screening program for infants, permitting children born deaf, or with severe hearing impairments, to be discovered very early. In general, children that are born deaf can get a CI implanted at about one year of age, if there are no other contraindications. Internationally it has become increasingly common for implants to be inserted at even lower ages, sometimes even as young as five months of age. For small children who receive CI's at an early age it is not possible to perform measurements based on the child making subjective assessments of how the sound is perceived when the electrical stimulation is altered through the implant. Also, small children cannot judge and report back the quality of the sound. Instead, objective measurements are commonly used since they do not require the active participation of the child, along with observations of the child and how it spontaneously reacts to the sound stimulation. A common objective measurement is to find the lowest level of electrical stimulation required to obtain a response from the auditory nerve, i.e. the electrically evoked action potential (ECAP) threshold. The CI manufacturer Cochlear Ltd has developed an automatic system for this measurement. Based on such measurements, as the automatic ECAP-measurement, the electrical stimulation from the implant can adjusted to the so-called MAP, where the minimum and maximum stimulation levels (T- respectively C-levels) are set for each individual electrode on the implant to create the dynamic range of electrical stimulation. This MAP then becomes the basis for the child's ability to perceive sound. Clinically, today (at Sahlgrenska University Hospital, Gothenburg, Sweden) a basic programming of the MAP is performed based on ECAP measurements, after which adjustment of only the overall level is carried out based on the child's reactions. However, no subjective measurement is made regarding threshold levels of stimulation through the implant or that the child actually perceives medium sound equally across the different channels. When the child can participate in sound field audiometry, adjustments of the MAP settings are made to get a straight audiogram, but basically, the children continue to use the setting based on the ECAP measurement. Adult patients with acquired deafness receiving CI are managed in a different manner than the children. The programming of the implant for adults is based on subjective measurements of how stimulation via individual electrodes is perceived. By measuring thresholds for individual electrodes, i.e. minimum audible stimulation (T-levels) and levels where stimulation is immediately below unpleasant strong (C-levels), then the MAP is programmed with an individual dynamic range for each electrode. To our knowledge no previous study have explored how the MAP based on an ECAP measurement endures over time or if a re-programming should be carried out when the child reliably can participate in behavioral measurements, which is about seven years of age in terms of measuring T-levels. Studies have shown that there is a correlation between ECAP-thresholds and T- and C-levels for people who can participate actively. However, the relationship is relatively weak and some researchers have even considered it too weak for ECAP thresholds to be the basis for programming the implant. However, in most clinics, these thresholds are used as a basis for programming CI to small children. Several of those who work with programming the MAP in small children claims to witness an adaptation in sensitivity of the auditory nerve to the applied stimulation; indicating that the results of the objective measurement could gradually change if there is an alternation in stimulation levels. However, there are no studies at this time that neither confirm nor deny this. The aim of this project is to investigate and clarify how children who receive CI at an early age should be monitored and to evaluate the objective ECAP measurement as a basis for setting stimulation levels. It also aims to investigate if there is any change in the result of the ECAP measurement after adjustment has been made in the MAP. After completion of the study, the goal is to offer a better and more knowledge-based (re-) habilitation for children who receive CI's, for whom there are currently no definite guidelines for programming and follow-up. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06320626 -
Pharmacokinetic-guided Dosing of Emicizumab
|
Phase 4 | |
Completed |
NCT04011852 -
The Role of Chest Electrical Impedance Tomography in the Pediatric Ventilator Weaning
|
||
Completed |
NCT03497663 -
VIA Family - Family Based Early Intervention Versus Treatment as Usual
|
N/A | |
Recruiting |
NCT05016271 -
Health Benefits of Air Purifiers in Primary School Students
|
N/A | |
Completed |
NCT02551978 -
Kids Obesity Prevention Program - Study (KOP)
|
N/A | |
Completed |
NCT02240368 -
Performance Evaluation of the Depth of Anesthesia Monitors in Pediatric Surgery
|
||
Completed |
NCT03946137 -
Chest Therapy and Postural Education in Children With Cerebral Palsy
|
N/A | |
Completed |
NCT01918020 -
Impact Study of Minnesota SNAP-Ed Health and Nutrition Education Programs
|
N/A | |
Completed |
NCT01267097 -
The PAC Study: Parents as Agents of Change in Pediatric Weight Management
|
N/A | |
Recruiting |
NCT04022460 -
Using Personal Mobile Technology to Identify Obstructive Sleep Apnea in Children With Down Syndrome (UPLOAD)
|
||
Completed |
NCT05538039 -
Reducing Anxiety of Children and Their Parents in the Pre-elective Surgery Process
|
N/A | |
Completed |
NCT03156465 -
Iowa Cochlear Implant Clinical Research Center Hybrid L24 and Standard Cochlear Implants in Profoundly Deaf Infants
|
N/A | |
Not yet recruiting |
NCT05914324 -
Outpatient Pediatric Pulse Oximeters in Africa
|
N/A | |
Not yet recruiting |
NCT04827108 -
Psychometric Properties of the Chinese Version of PeNAT
|
||
Recruiting |
NCT04888195 -
Symptom Clusters in Hong Kong Chinese Children With Blood Cancer
|
||
Not yet recruiting |
NCT04853303 -
VR to Improve CINV, Sleep and Pain Among Children With Cancer in HK
|
N/A | |
Completed |
NCT05374902 -
Efficacy of Animation, Buzzy, and Multiple Interventions on Pain in Children
|
N/A | |
Completed |
NCT04665453 -
Dexmedetomidine and Melatonin for Sleep Induction for EEG in Children
|
N/A | |
Completed |
NCT04082247 -
Healthy Children 2021 Study in Childcare Centers
|
N/A | |
Completed |
NCT02858531 -
Predictive Tracking of Patient Flow in the Emergency Services During the Virus Winter Epidemics
|