Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05639049
Other study ID # Enova
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date November 1, 2022
Est. completion date November 1, 2024

Study information

Verified date November 2022
Source Vienna Institute for Research in Ocular Surgery
Contact Christoph Spartalis, MD
Phone 01 91021
Email office@viros.at
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Comparison of the capsular bag performance of two hydrophobic intraocular lenses of different design.


Description:

Continuous improvements in cataract surgery technique, intraocular lens (IOL) materials, and design over the past few decades, have led to a more safe procedure with satisfactory refractive outcomes and a short rehabilitation time. By that, patients' expectations concerning their postoperative visual quality and refractive outcome are increasing. However, two main problems might occur after cataract surgery: instability of the IOL position in the capsular bag and formation of posterior capsule opacification (PCO). Both may decrease the optical performance of an IOL. The performance of an IOL depends on its behaviour in the capsular bag, which has an influence on the anterior chamber depth (ACD), as well as the postoperative refractive shift, the tilt and decentration of the IOL. Several factors such as IOL design and material, capsulorhexis size, capsular bag diameter, and capsular fibrosis or shrinkage may lead to a suboptimal IOL position. Misalignment of an IOL away from the retina leads to a myopic shift, while towards the retina leads to a hyperopic outcome. This explains why inaccurate prediction of postoperative ACD remains the main source of error in IOL power calculation. One main goal of modern cataract surgery is to yield a low and predictable ACD shift as well as low degrees of IOL tilt and decentration after surgery in order to achieve ideal optical performance of the IOL. Another aspect of capsular bag performance of an IOL is posterior capsule opacification (PCO). PCO is one of the most frequent long-term complications after cataract surgery leading to dissatisfying results by decreased visual function. Source of PCO are lens epithelial cells from the equator of the lens capsule, which acquire the ability to migrate and proliferate, causing epithelial ingrowth between the IOL and the posterior capsule. It is estimated that PCO occurs at a rate of 12% one year, 21% three years, and 28% five years after cataract surgery. PCO can be treated with neodymium-doped yttrium aluminium garnet (Nd:YAG) laser capsulotomy. However, complications including an increase in intraocular pressure, ocular inflammation, cystoid macular edema, and retinal detachment may occur after this treatment. Hence lower rates of PCO would improve patients long term safety following cataract surgery. Moreover, it would increase patient satisfaction. The material and design of an IOL may have an effect on the formation of PCO. Sharp optic edge design has been shown to be a major factor in the prevention of PCO. Furthermore, acrylic and silicone hydrophobic materials showed a lower risk for PCO formation and lower rates of postoperative Nd:YAG laser capsulotomy than hydrophilic IOLs. In this study the ACD shift and IOL tilt and centration as well as the PCO formation of an IOL with a new design, the Enova GF3 IOL will be compared to a standard monofocal IOL, the Tecnis 1-piece ZCB00. 90 eyes of 45 patients will be included into this study. According to the randomization, the ENOVA GF3 will be implanted in one eye and the ZCB00 in the fellow eye of each patient. Follow-up visits will take place 1 week, 3 months, 6 months, and 12 months after the surgery. At each visit a slitlamp examination, non-contact intraocular pressure measurement, refraction, visual acuity testing, biometry, retroillumination photography, and purkinjemeter assessments will be performed.


Recruitment information / eligibility

Status Recruiting
Enrollment 45
Est. completion date November 1, 2024
Est. primary completion date November 1, 2023
Accepts healthy volunteers No
Gender All
Age group 21 Years to 105 Years
Eligibility Inclusion Criteria: - Age-related bilateral cataract - Age 21 or older - Visual acuity > 0.05 - Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant - Written informed consent prior to surgery Exclusion Criteria: - Relevant other ophthalmic diseases such as pseudoexfoliation syndrome (PEX), traumatic cataract, intraoperative Floppy Iris Syndrome (IFIS), or other co-morbidities that could affect capsular bag stability (e.g. Marfan syndrome) - Any ophthalmic comorbidity that may compromise visual function or create problems with measurements (e.g. macular degeneration, amblyopia, corneal scars, etc.) - Previous ocular surgery or trauma - Pregnancy (pregnancy test will be taken in women of reproductive age)

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Enova GF3
Enova GF3, monofocal IOL
Tecnis 1-piece ZCB00
Tecnis 1-piece ZCB00, monofocal IOL

Locations

Country Name City State
Austria Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna Vienna

Sponsors (1)

Lead Sponsor Collaborator
Vienna Institute for Research in Ocular Surgery

Country where clinical trial is conducted

Austria, 

Outcome

Type Measure Description Time frame Safety issue
Primary Anterior chamber depth Anterior chamber depth will be assessed using a biometry device and will be compared between both monofocal IOLs 24 months
Secondary IOL tilt IOL tilt will be assessed using the purkinjemeter and will be compared between both IOLs 24 months
Secondary Posterior capsule opacification (PCO) PCO will be assessed using retroillumination photography and will be compared between both groups 24 months
Secondary Visual acuity Visual acuity will be assessed in the far and intermediate distance using ETDRS charts and will be compared between both groups 24 months
Secondary Catquest 9SF questionnaire The Catquest 9SF questionnaire will be handed out to all patients 24 months
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A