Clinical Trial Summary

Biometry has become one of the most important steps in modern cataract surgery. The axial length of the eye may be measured by ultrasound (either contact or immersion) or by optical means. Non-contact optical biometry has become the gold-standard because of its ease of use, accuracy, and reproducibility. However, the main disadvantage of the optical methods is their inability to obtain axial length measurements in approximately 10% of eyes, typically those with dense posterior subcapsular cataracts. By Using SS-OCT device, it has been reported that the AL measurements cannot be made in 0.6 to 7.4% of cases . Therefore, measurement by US biometer is still necessary for advanced cataract. The ultrasound measure the LA between the corneal epithelium and the vitreomacular interface. Ultrasound in B mode (or Brilliance) with the help of the control vector allows a 2-dimensional control of the plan used for measurement. This method is used in current practice in our centers when LA measurements is not possible with our optical SS-biometer. Recently Alcon has integrated the ARGOS® biometer's diagnostic testing with Alcon's Cataract Refractive Suite technologies. ARGOS® is a non-invasive, non-contact biometer based on swept-source optical coherence tomography (SS-OCT). The device is intended to acquire ocular measurements as well as perform calculations to determine the appropriate intraocular lens (IOL) power and type for implantation during intraocular lens placement. ARGOS® measures the following 9 parameters: Axial Length, Corneal Thickness, Anterior Chamber Depth, Lens Thickness, K-values (Radii of flattest and steepest meridians), Astigmatism, White-to-White (corneal diameter) and Pupil Size. The Reference Image functionality is intended for use as a preoperative and postoperative image capture tool. ARGOS® includes an operation mode for when the retina is hardly or not visible at all denominated the "Enhanced Retinal Visualization mode" (ERV) that allows, in most cases, visualization of the retina. This signal in the retinal region is enhanced by shifting the coherence function (Argos Users manual). In a prospective observational study conducted in 2 centers in USA involving 107 eyes, they have evaluated the repeatability and reproducibility of ARGOS® measurements in comparison with IOLMaster®500 and LENSTAR LS 900. They have shown that the AL acquisition rate was higher with ARGOS® (96%) compared with both LENSTAR LS 900 (79%) and IOLMaster®500 (77%). The reason was that ARGOS® was more successful at measuring AL in eyes with dense cataract.


Description:

Our recent experience with Argos has shown that LA measurements were even possible with our without ERV mode in case of very dense (ie: cataracts in diabetic patients) or posterior subcapsular cataracts. These observations lead us to propose a retrospective study to compare Argos to our gold standard "ultrasound biometer in mode B" for LA measurements in case of failure with the conventional optical biometer used in our current practice (Lenstar LS900, IOLMaster 500, 700) In current practice, the biometry measurements are conducted with our conventional optical biometer during the visit prior to cataract surgery. At the same time, measures will be conducted on Argos with or without the ERV mode If axial length measurements are impossible with our conventional optical biometer due to the level of cataract density, axial length measurements will be conducted with our ultrasound biometer in mode-B (Quantel Medical, Aviso S with the 10MHz probe) according to our current practice. We will retrospectively collect the consecutive data from eyes for which axial length measurements with our conventional biometer were not possible


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 110
Est. completion date May 2023
Est. primary completion date February 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Patient over 18 years of age - All consecutive patient measured on Argos and any other conventional optical biometer and presenting a failure with one of the conventional optical biometer in AL measurement due to cataract density Exclusion Criteria: - Silicon tamponade in the posterior segment - Patients who are informed and objected to participating to the research - Patient subject to legal protection measures.

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
France Hôpital Avicenne Bobigny

Sponsors (1)

Lead Sponsor Collaborator
Assistance Publique - Hôpitaux de Paris

Country where clinical trial is conducted

France, 

Outcome

Type Measure Description Time frame Safety issue
Primary To describe axial length (AL) measured by the Argos biometer in case of measure failure with a conventional optical biometer and to compare it with the AL measured with ultrasound biometry in B-mode (considered to be the gold standard) Axial length (AL) in millimeters obtained with Argos and ultrasound biometer in B-mode scans (considered to be the reference method for dense cataract) 2 months
Secondary to describe Pachymetry in micrometers obtained with Argos biometer, conventional biometer and ultrasound biometer Pachymetry in micrometers obtained with Argos biometer, conventional biometer and ultrasound biometer 2 months
Secondary to measure anterior chamber depth in millimeters obtained with Argos biometer, conventional biometer and ultrasound biometer Anterior chamber depth in millimeters obtained with Argos biometer, conventional biometer and ultrasound biometer 2 months
Secondary to measure lens thickness obtained with Argos biometer and ultrasound biometer Lens thickness obtained with Argos biometer and ultrasound biometer 2 months
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A