Cataract Clinical Trial
Official title:
Comparing Two Digital Marking Systems
Comparison of the alignment axis of the Alcon Verion and the Zeiss Callisto alignment systems intraoperatively
In most patients undergoing cataract surgery, emmetropia can be achieved by implantation of a monofocal intraocular lens (IOL). However, several studies have shown that approximately 20% to 30% of patients who undergo cataract surgery have a preexisting corneal astigmatism of 1.25 diopters (D) while the prevalence of corneal astigmatism >2.00 D is 8% and over >3.00 D 2.6%. This astigmatism, if not corrected during surgery, leads to postoperative spectacle dependence. In patients without contraindications and a desire to achieve postoperative freedom from spectacles for distance vision, correction of astigmatism can be achieved at the time of surgery by using toric IOLs. A number of factors relating to corneal astigmatism are critical to lens selection and positioning.The most important factors are the preoperative corneal measurements and the correct alignment of the toric lens itself. Each degree of deviation results in a 3% reduction in astigmatism correction. The introduction of digital marking systems is intended to minimize the disadvantages of manual marking, such as tilting of the head during marking, incorrect and smudged marking. In addition to several different manual marking methods, there is also a range of digital markers which have been proven to be equal or even better than manual marking. These include among others the Callisto Eye with Z-Align and the Alcon VERION Digital Marker. The principle of these digital marking systems is based on a preoperative photo which is recorded in the course of biometry where the keratometry values are obtained. In the further course, the steep axis is determined on the basis of this image and the target axis is projected on to the eye intraoperatively. Beside the ideal implantation axis for the T-IOL, the size of the capsulorhexis and position, as well as incision placement can be displayed. In the course of this study, we will investigate the alignment axis of the two most used digital guidance systems from Alcon and Zeiss. A head to head comparison has already been carried out by Hura et al. in 2017. 15 eyes of 15 patients will be included into this study. There will only be one preoperative study visit, on the day of surgery, where reference pictures with a slitlamp camera and the biometers will be taken. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |