Clinical Trials Logo

Clinical Trial Summary

Comparison of the alignment axis of the Alcon Verion and the Zeiss Callisto alignment systems intraoperatively


Clinical Trial Description

In most patients undergoing cataract surgery, emmetropia can be achieved by implantation of a monofocal intraocular lens (IOL). However, several studies have shown that approximately 20% to 30% of patients who undergo cataract surgery have a preexisting corneal astigmatism of 1.25 diopters (D) while the prevalence of corneal astigmatism >2.00 D is 8% and over >3.00 D 2.6%. This astigmatism, if not corrected during surgery, leads to postoperative spectacle dependence. In patients without contraindications and a desire to achieve postoperative freedom from spectacles for distance vision, correction of astigmatism can be achieved at the time of surgery by using toric IOLs. A number of factors relating to corneal astigmatism are critical to lens selection and positioning.The most important factors are the preoperative corneal measurements and the correct alignment of the toric lens itself. Each degree of deviation results in a 3% reduction in astigmatism correction. The introduction of digital marking systems is intended to minimize the disadvantages of manual marking, such as tilting of the head during marking, incorrect and smudged marking. In addition to several different manual marking methods, there is also a range of digital markers which have been proven to be equal or even better than manual marking. These include among others the Callisto Eye with Z-Align and the Alcon VERION Digital Marker. The principle of these digital marking systems is based on a preoperative photo which is recorded in the course of biometry where the keratometry values are obtained. In the further course, the steep axis is determined on the basis of this image and the target axis is projected on to the eye intraoperatively. Beside the ideal implantation axis for the T-IOL, the size of the capsulorhexis and position, as well as incision placement can be displayed. In the course of this study, we will investigate the alignment axis of the two most used digital guidance systems from Alcon and Zeiss. A head to head comparison has already been carried out by Hura et al. in 2017. 15 eyes of 15 patients will be included into this study. There will only be one preoperative study visit, on the day of surgery, where reference pictures with a slitlamp camera and the biometers will be taken. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05220683
Study type Interventional
Source Vienna Institute for Research in Ocular Surgery
Contact Johannes Zeilinger, MD
Phone +43 (1) 91021
Email office@viros.at
Status Recruiting
Phase N/A
Start date July 1, 2021
Completion date July 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A