Source University of Coimbra
Contact Jaime Santos, PhD
Phone +351 239 796 200
Email jaime@deec.uc.pt
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study aims to assess the performance of an ultrasonic system for automatic classification of cataract type and severity, as well as the estimation of the optimal phacoemulsification energy. Ultrasonic signals from the lens will be acquired with the Experimental Medical Device (ESUS) in participants with cataract, and in healthy subjects (control). The proposed technique may represent an important advance in cataract treatment. The quantitative and automatic classification of cataract type and severity, and the estimation of the optimal phacoemulsification energy is may represent a valuable tool for surgical planning, reducing complications associated to excessive levels of phacoemulsification energy, as well as the times spent on surgeries. This device may be relevant not only for patients, but also for public health systems, reducing waiting lists and associated costs.


Description:

This is a prospective, pivotal, non-blinded study. Fifty (50) participants will be recruited at the Coimbra Surgical Center of Portugal. The study will be conducted on subjects with age-related cataract, and on healthy subjects as control group. Since this is a pilot study, no sample size estimation has been implemented. The statistical power will be determined at the end of the study. Only per-protocol participants will be considered on statistical analysis. Procedures involved. The ultrasonic system (Experimental Medical Device - ESUS) works in A-scan mode, with an acoustic working frequency of 20 MHz. From the ultrasonic signals backscattered from the lenses, acoustic parameters will be extracted, and used for automatic algorithms implementation. This study will be implemented once. Slit lamp with LOCS III classification will be used as comparator. Contrast sensitivity test results will be used for incipient cataract detection, where slit lamp may present some limitations. Optical coherence tomography and specular microscopy will help on detecting postoperative complications; other complications identified by the physician will be also considered. Surgical parameters as phacoemulsification energy and surgical time will help on phacoemulsification energy evaluation. Safety assessment. The system uses an ophthalmic probe. There are not anticipated adverse events related to the procedures involved in the use of the ultrasonic system, or any other procedure in the protocol. The safety conditions will be monitored through the occurrence of unanticipated adverse events or serious adverse events. If these situations occur, the event will be reported to the competent authorities (in agreement with the current regulation) and the corrective actions will be implemented.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date September 1, 2022
Est. primary completion date March 1, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 50 Years to 70 Years
Eligibility Inclusion criteria: Cataract group: - Patients with age-related cataract; - Indication of phacoemulsification surgery Control group: • Patients without cataract Exclusion criteria: • Presence of any other ophthalmological condition or systemic disease that could affect the results

Study Design


Related Conditions & MeSH terms

  • Cataract
  • Ultrasound Therapy; Complications

Intervention

Device:
Eye Scan Ultrasound System (ESUS)
• For the ultrasonic signals acquisitions, an ophthalmic probe working in A-mode scan, must be coupled to the cornea. To reduce the discomfort generated by coupling the probe, topical anaesthesia (oxybuprocaine hydrochloride) will be applied before starting acquisitions. However, if the participant has some known contraindication to this anaesthetic, in replacement, a disposable neutral contact lens will be used as coupling medium between the probe and the cornea. The acquisitions are initiated through a starting button in the system's user interface, and the probe must be kept by few seconds for automatic signals records. During this period, signals are visualized in the user interface. Finally the probe is uncoupled, and the acquired signals are saved.

Locations

Country Name City State
Portugal Centro Cirúrgico de Coimbra (CCCI) Coimbra

Sponsors (2)

Lead Sponsor Collaborator
University of Coimbra Fundação para a Ciência e a Tecnologia

Country where clinical trial is conducted

Portugal, 

Outcome

Type Measure Description Time frame Safety issue
Primary Presence of Cataract Presence of cataract obtained with the Experimental Medical Device (ESUS) baseline
Secondary Cataract classification Cataract type and severity obtained with the Experimental Medical Device (ESUS) - based on the LOCS III (Lens Opacity Classification System) baseline
Secondary Cataract hardness Cataract hardness estimated with the Experimental Medical Device (in Gpa) before the intervention/procedure/surgery
Secondary Phacoemulsification energy Phacoemulsification energy level estimated with the Experimental Medical Device in the participants performing cataract surgery (considering the phacoemulsification energy parameters provided by the phacoemulsifier). immediately after the intervention/procedure/surgery
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A