Clinical Trials Logo

Clinical Trial Summary

Purpose of The Study:

The purpose of this study is the following:

A)To gather age-related normative visual acuity data for the Vimetrics Central Vision Analyzer (CVA, Vimetrics, LLC, Media, Pa) B)To gather visual acuity data for patients with known ocular problems, including cataract and maculopathy.

C)To correlate and compare the CVA visual acuity findings with the acuity measured with standard LogMAR acuity charts viewed under similar conditions of contrast and lighting


Clinical Trial Description

The measurement of visual acuity involves the determination of the smallest high contrast target that can be resolved by the patient. Classically, this has been approached by the use of letter style optotypes, each having successively smaller stroke and gap resolution. More recently, the arrangements of letter charts have been redesigned with a logarithmic scale and with attention being paid to the uniformity of other effects such as crowding or of the choice of optotype. The resultant Ferris-Bailey-Lovie chart has become a standard for acuity testing, especially for clinical research. The letters of such acuity charts have a 0.1 logMAR step progression (1.26 X) between lines and have 5 letters per line. It has been noted that the logMAR chart could have greater resolution with finer steps between the lines and with improved repeatability by converting to a letter-by-letter scoring system.

While these advances have improved the resolution and reliability of acuity measures, they require relatively cumbersome wall charts and do not provide any of the advantages of an interactive program that would enable a threshold to be approached by stimulus presentation on both the seeing as well as non-seeing sides.

The Vimetrics CVA is an interactive computer device that measures threshold visual acuity by presenting a Landolt-C with the gap randomly tumbled in one of 4 positions to which the patient responds with a response pad. The threshold is approached in a logarithmic, staircase fashion to define the test subject's acuity threshold with a resolution similar to letter by letter scoring in chart testing but with the ability to rapidly test under a number of conditions of luminance and contrast that simulate activities of daily living.

The CVA determination of visual acuity under six conditions of contrast and lighting will be compared with that acquired by logMAR chart testing under similar conditions. ;


Study Design

Observational Model: Case-Only, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT02028351
Study type Observational
Source Sinclair Technologies, LLC
Contact
Status Completed
Phase N/A
Start date January 2008
Completion date March 2009

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A