Cataract Clinical Trial
Official title:
GALILEI Lens Professional vs. Predicate Devices: a Comparison Study
Study question: How does the new GALILEI Lens Professional compare to predicate devices? Study hypothesis: The GALILEI Lens Professional achieves a better precision in the postoperative, calculated target refraction with cataract surgeries than predicate devices, and it is more versatile in the measurable parameters as well as more user-friendly.
Background: An accessory to the commercially available GALILEI Dual-Scheimpflug Corneal
Topographer/Keratometer with the name "EBR Accessory" was developed by the company Ziemer
Ophthalmic Systems AG for the measurement of intraocular distances. The combination is called
"GALILEI Lens Professional". The measurement principle is based on on short coherence
interferometry/-reflectometry, which has gained wide-spread application and has been applied
clinically, including one of the members of this study group, for the precise measurement of
axial, intraocular distances (12.1.). Such EBR Accessory measurements, in combination with
measurements by the GALILEI, may be applied to given intra-ocular lens (IOL) types and IOL
equations, an permit the calculation of suggested IOLs that are implanted during cataract
surgery, in order to achieve the desired vision correction. To register this accessory for
sale, the precision and agreement to existing devices with similar applications ("predicate
devices") must be demonstrated. One complete measurement consists of a
cornea-topography/keratometry scan, followed immediately by three consecutive, axial biometry
scans of the anterior segment (cornea and crystalline lens) and - after a short re-alignment
- three consecutive, axial biometry scans of the retina. The measurement process is
continuous, but divided in two steps. Blinking by the patient is possible in between the two
steps, which increases patient comfort and, in certain cases, measurement success. Precision
is evaluated by three repeated, complete measurements with the GALILEI Lens Professional and
each predicate device. Two standard devices with comparable optical technology that are used
in routine cataract surgery were declared as predicate devices. These two devise are
typically used in combination with standard keratometers, as which the GALILEI Lens
Professional may be employed as well.
Goal: The comparison of the GALILEI Lens Professional to predicate devices with respect to
precision in measuring postoperative, calculated target refractions in cataract patients, and
versatility of measurable quantities.
;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
| Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
| Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
| Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
| Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
| Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
| Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
| Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
| Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
| Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
| Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
| Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
| Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
| Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
| Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
| Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
| Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
| Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
| Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
| Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |