Cataract Clinical Trial
Official title:
Comparison of the Quality of Vision Provided by AMO Tecnis Z9000 Three-piece Silicone Posterior Chamber Intraocular Lens and Alcon Laboratories MA60 Acrysof Three-piece Acrylic Posterior Chamber Intraocular Lens
This study is a comparison of the quality of vision provided by AMO Tecnis Z9000 three-piece silicone posterior chamber intraocular lens and Alcon Laboratories MA60 three-piece acrylic posterior chamber intraocular lens.
Today, intraocular lenses (IOLs) are routinely implanted after cataract extraction. Cataract
surgical techniques are constantly developing due to innovations in surgical implantation
and IOL manufacturing processes. Although material development and surgical implantation
have advanced extensively during the past several years, there has been little attention
paid to the improvement of the optical quality of IOLs.
It has been documented that the vision of an IOL patient is no better than that of a person
with healthy eyes of a similar age, i.e., when a 65-year-old patient with cataracts has them
removed and implanted with an IOL, the resulting visual outcome is no better than the visual
quality of a 65-year-old without cataracts. The fact that the visual quality of the IOL
patients is no better than that of their same-age counterparts is surprising because an IOL
is optically superior to the natural crystalline lens. This fact may be explained by
aberrations.
Aberrations cause incoming light that would otherwise be focused to a point to be blurred,
which in turn causes a reduction in visual quality. This reduction in quality is more severe
under low luminance conditions because ocular aberrations increase when the pupil size gets
larger. The Z9000 is an IOL that is designed to counteract the spherical aberration of the
cornea and thus improve the resulting visual quality of IOL patients.
Different materials and lens designs result in different visual quality. The handling of the
lens, proper centration in the eye, the postoperative course, and the optical image may vary
depending on the design of the lens. Two lenses will be compared: AMO Tecnis Z9000
three-piece silicone lens and Alcon Laboratories MA60 three-piece acrylic lens.
This will be a randomized, evaluator-masked study in bilateral cataract surgery patients.
Each patient will be assigned to a AMO Tecnis Z9000 lens in one eye and an Alcon
Laboratories MA60 lens in the other eye. All first surgeries will be on the right eye. A
randomization list will be used to decide lens allocation.
A total of 80 patients (men and women) from the Singapore National Eye Centre will be
enrolled in the study. All patients will undergo wavefront analysis 90-120 days
postoperatively.
The two lens models look different, even in the eye, after implantation. It is not possible
to mask the individual investigator at the time of surgery or personnel responsible for
conducting the clinical ocular examinations (e.g., evaluation of complications, posterior
capsule, IOP, pupil size) and optic evaluations (e.g., evaluation of the IOL).
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
| Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
| Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
| Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
| Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
| Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
| Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
| Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
| Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
| Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
| Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
| Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
| Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
| Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
| Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
| Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
| Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
| Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
| Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
| Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |