Cardiac Output, Low Clinical Trial
Official title:
Noninvasive Versus Invasive Methods in Assessment of Hemodynamic Parameters in Respiratory ICU Patients
The study aims at evaluating effectiveness of noninvasive cardiometry in assessment of cardiac parameters in critically ill patients in respiratory ICU in comparison to invasive methods as indirect fick's and thermodilution methods using pulmonary artery catheter.
Patients and methods A. Study setting The study will be conducted in Assiut University Hospital, in respiratory intensive care unit. B. Study design This study is a cross-sectional study C.Methods Firstly, invasive methods: The Fick method is a "gold standard" measurement of cardiac output. This method is based on the principle described by Adolfo Fick in 1870, according to which the total uptake or release of a substance by an organ is the product of the blood flow through the organ and the arteriovenous concentration difference of the substance. The oxygen uptake in the lungs is the product of the blood flow through the lungs and the arteriovenous oxygen content difference. Therefore, the cardiac output, CO, can be calculated using the equation: CO= VO2/(CaO2-CvO2) Where VO2 is the oxygen consumption by the lungs and (CaO2-CvO2) is the arteriovenous difference in oxygen. VO2 can be compensated for, based on calculated body surface area (BAS), using equation of = 125 × BSA. The arteriovenous difference is computed by receiving samples of arterial oxygen saturation through arterial blood gases, and mixed venous oxygen saturation through receiving blood from the pulmonary artery using PAC. Another method is thermodilution, this method uses a special thermistor tipped catheter (Swan-Ganz catheter) inserted from a central vein into the pulmonary artery. A normal saline (temperature 0 degrees Celsius) is injected into the right atrium from a proximal catheter port. This solution causes a decrease in blood temperature, which is measured by a thermistor placed in the pulmonary artery catheter. The pulmonary artery catheter is attached to the cardiac output computer, which displays a curve and calculates output and derived indices automatically. Secondly, noninvasive methods Electrical cardiometry will be attached to patient using four electrodes. Two electrodes will be on the left side of the neck and the two other electrodes on the left side of the chest opposite to the xiphoid process at the mid-axillary line. This allow for the continuous measurement of the changes of electrical conductivity within the thorax. By sending low amplitude, high frequency electrical current through the thorax, the resistance that the current faces (due to several factors) is measured. Through advanced filtering techniques, Electrical Cardiometry (EC) is able to isolate the changes in conductivity created by the circulatory system. This can determine the stroke volume, cardiac output and other hemodynamic indcies. Another noninvasive method which is used in assessment of cardiac parameters is echocardiography. D. Action plan and outcomes 1. All patients' data regarding age, gender, sex and essential diagnosis will be taken. 2. Patients' vital signs especially blood pressure and heart rate. 3. Hemoglobin level will be acquired for all patients. 4. Arterial blood gases especially arterial oxygen saturation. 5. Venous blood gases obtained through Swan Ganz catheter. 6. Patients' body surface area using patient height and weight will be obtained 7. All patients will have cardiac parameters assessment using electrical cardiometry. 8. Echocardiography will be recorded for patients. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05070819 -
Atrial Natriuretic Peptide in Assessing Fluid Status
|
N/A | |
Recruiting |
NCT05492968 -
The Effect of Epinephrine, Norepinephrine and Phenylephrine on Intraoperative Hemodynamic Performance
|
Phase 4 | |
Completed |
NCT03444545 -
Continous Cardiac Output - Non-Invasive Evaluation (CONNIE)
|
||
Recruiting |
NCT04064177 -
Non-invasive Continuous Cardiac Output Monitoring in Preterm Infants Study
|
||
Withdrawn |
NCT03058653 -
Use of a Mini-fluid Bolus to Identify Fluid Responsiveness
|
N/A | |
Completed |
NCT02880683 -
Cardiac Output Autonomic Stimulation Therapy for Heart Failure (COAST-HF) - Human NeuroCatheter Study
|
N/A | |
Recruiting |
NCT00989508 -
Myocardial Protection With Perhexiline in Left Ventricular Hypertrophy
|
Phase 2/Phase 3 | |
Completed |
NCT04955184 -
Comparing Cardiac Output Measurements Using a Wearable, Wireless, Non-invasive PPG-Based Device to a Swan Ganz Catheter
|
||
Completed |
NCT02964663 -
Comparison of the Ability of the esCCO and the Volume View to Measure Trends in Cardiac Output During Cardiac Surgery
|
N/A | |
Completed |
NCT04641949 -
Methoxyflurane and Fentanyl in LBNP
|
Phase 4 | |
Recruiting |
NCT04191408 -
Predictive Ability of PEEP Induced Changes in CVP to Predict Volume Responsiveness in Mechanically Ventilated Patients After Major Abdominal Surgery
|
N/A | |
Completed |
NCT01892696 -
Effects of Inspiratory Flow Waveforms on Preload
|
N/A | |
Recruiting |
NCT02728791 -
Comparison of Allows Measurement of Cardiac Output Between Clearsight System and Transpulmonary Thermodilution
|
N/A | |
Completed |
NCT03930979 -
The Effect of Hyperoxia on Cardiac Output
|
||
Recruiting |
NCT04755764 -
Effect of Labetalol, Atenolol, and Nifedipine on Maternal Hemodynamics Measured by ICG in Early Pregnancy
|
||
Enrolling by invitation |
NCT02702544 -
Effect of Passive Leg Raising for Fluid Responsiveness
|
N/A | |
Completed |
NCT01880684 -
Validation of Capnography as a Predictor of Cardiac Output Change as Measured by FloTrac
|
Phase 2 | |
Recruiting |
NCT05035719 -
Comparison Studies Comparing Hemodynamic Parameters Provided by the Caretaker Against Respective Gold Standard References
|
||
Not yet recruiting |
NCT04774978 -
Real-time Continuous Cardiac Output Measurements
|
N/A | |
Completed |
NCT02485782 -
Changes in Volumetric Hemodynamic Parameters Induced by Fluid Removal on Hemodialysis
|
N/A |