Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to evaluate the performance of FDA-cleared SAVI SCOUT Breast Localization and Surgical Guidance System (SCOUT) over a longer duration prior to surgery. The device is a non-wire system, which uses nonradioactive light-activated radar, to provide breast surgeons with real-time guidance to locate and remove the target lesion in the breast and/or axillary tissue. The SCOUT device standard of care use is placement up to 30 days prior to surgery to assist surgeons in the localization and retrieval of breast/axillary lesions. Routine image-guided methods (Mammography, Ultrasound, and CT) are used. In this study, investigators will assess the longer term placement of the SCOUT device over an extended time (31 - 365 days) in order to address the needs of patients who require neoadjuvant treatment prior to definitive surgery.


Clinical Trial Description

The SAVI SCOUT (Cianna Medical, Inc.) surgical guidance system received 510(k) U.S. Food and Drug Administration (FDA) approval in August 2014. This system is used as a standard of care since 2015 in the Memorial Healthcare System (MHS) operating rooms by experienced breast surgeons (over 150 MHS breast cancer patients and over 5,000 U.S. breast cancer patients as of September 2016). In MHS standard of care practice, the device is placed at the target lesion(s) under image-guidance by the radiologist up to 30 days prior to surgery.

Patients with certain types of breast cancer undergo neoadjuvant treatment with biologic (hormonal) and/or chemotherapy with the goal of decreasing the tumor volume prior to definitive surgery. If the original cancer lesion(s) resolve completely, this is called complete pathologic response (pCR). pCR and even a partial response, while good for the patient, can result in disappearance or poor visualization of the target and often render pre-operative image-guided localization by the radiologist more difficult and less reliable. This can result in unintended larger, more disfiguring breast cancer surgery. Therefore, if the SCOUT device can be placed prior to treatment response, when the lesion is clearly visualized on imaging, accurate image-guided targeting is optimal and thus placement and subsequent surgery should be more accurate. If this pilot study demonstrates successful performance of the device without device-related complications, it will bring improved value to future patients who will require fewer and/or less extensive pre-operative and surgical procedures. Some value may also be provided to subjects as the targeting before tumor shrinkage is expected to be more accurate.

Thus, this pilot study will assess the performance of FDA-cleared SCOUT system over a longer duration prior to breast and/or axillary lymph node surgery. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03015649
Study type Interventional
Source Envision Healthcare Scientific Intelligence, Inc.
Contact
Status Completed
Phase N/A
Start date February 3, 2017
Completion date April 4, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT04854304 - Abbreviate or FAST Breast MRI for Supplemental Breast Cancer Screening for Black Women at Average Risk and Dense Breasts
Recruiting NCT01678170 - Clinical Application of Breast Blood-oxygen Functional Imaging Technology N/A
Completed NCT00039780 - Evaluation of BNP7787 for the Prevention of Neurotoxicity in Metastatic Breast Cancer Patients Receiving Weekly Paclitaxel Phase 3
Completed NCT02909452 - Continuation Study of Entinostat in Combination With Pembrolizumab in Patients With Advanced Solid Tumors Phase 1
Recruiting NCT04535466 - Diagnosis Predictive Modle for Dense Density Breast Tissue Based on Radiomics
Recruiting NCT01917279 - Capecitabine Maintenance Therapy Following Capecitabine Combined With Docetaxel in Treatment of mBC Phase 3
Recruiting NCT01427400 - The Use of Botulinum Toxin A in Two-Stage Tissue Expander/ Implant Breast Reconstruction Phase 4
Completed NCT05665894 - Vacuum-Assisted Evacuation (VAE) Of Symptomatic and/or Voluminous Breast Haematomas Following Surgeries And Percutaneous Procedures: a Retrospective Analysis
Not yet recruiting NCT04088110 - Pyrotinib Combined With Trastuzumab Plus Aromatase Inhibitor in Treatment of Breast Cancer Phase 2
Terminated NCT02997540 - Effect of Body Position and Probe Position on the Localization of Breast Mass
Terminated NCT01140776 - Clinical Evaluation of OSNA Breast Cancer System in Breast Cancer Patients Receiving Neoadjuvant Therapy N/A
Recruiting NCT04911101 - Performance Indicators and Patient Experience in 7G and 10G Vacuum-assisted Excision of Probably Benign Breast Lesions N/A
Completed NCT04554316 - Aesthetic Effect of Steri-Strip Orientation on Healing and Scar Appearance in Breast Surgery N/A
Suspended NCT04151368 - Surgical and Patient Reported Outcomes of Robotic Nipple-Sparing Mastectomy N/A
Completed NCT03743259 - To Evaluate the Efficacy and Safety of LuminoMark Injection in Patients With Nonpalpable Breast Lesions Phase 2
Recruiting NCT04605575 - Pyrotinib Plus Vinorelbine in Participants With HER2-positive Previously Treated Locally Advanced or Metastatic Breast Cancer Phase 2
Recruiting NCT05814224 - Monitoring luminAl Breast Cancer Through the Evaluation of Mutational and epiGeNEtic alteraTIons of Circulating ESR1 DNA N/A
Completed NCT02452333 - Oncoplastic Approach to Excisional Breast Biopsies N/A
Terminated NCT01372215 - Multi-Compression Spot Mammography N/A
Completed NCT00299039 - T3AI-Pain After Breast Surgery Phase 3