Breast Augmentation Clinical Trial
Official title:
Clinical Evaluation of the Safety and Performance of Fractional RF for the Treatment of Surgical Scars Following Breast Augmentation, Abdominoplasty or Face Lift
NCT number | NCT03467724 |
Other study ID # | CS0717 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | January 23, 2018 |
Est. completion date | April 13, 2020 |
Verified date | April 2023 |
Source | Venus Concept |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Split-body/face evaluator-blind study of the safety and performance of fractional RF for the treatment of surgical scars following breast augmentation, abdominoplasty or face lift. The study will enroll up to 50 female subjects requesting treatment of surgical scars following breast augmentation or abdominoplasty and up to 25 male and female subjects requesting treatment of surgical scars following face lift surgery. Subjects will receive a total of three treatments of their surgical scars at one-month intervals on one side of the body or face only. Subjects will be followed up at one, two, three and ten months after their last treatment. Outcomes will be compared to the non-treated side.
Status | Completed |
Enrollment | 75 |
Est. completion date | April 13, 2020 |
Est. primary completion date | April 13, 2020 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 20 Years to 75 Years |
Eligibility | Inclusion Criteria: 1. Healthy, female, subjects 20-60 years of age who are seeking treatment for their breast augmentation or abdominoplasty surgical scars or male and female patients 40-75 years of age who are seeking treatment for their face lift surgical scars. 2. A minimum of four weeks since surgery. 3. Able to read, understand and voluntarily provide written Informed Consent. 4. Able and willing to comply with the treatment/follow-up schedule and requirements. 5. Willing to avoid direct sunlight for the duration of the study. 6. Women of child-bearing age are required to be using a reliable method of birth control at least 3 months prior to study enrollment and for the duration of the study, and have a negative Urine Pregnancy test at baseline. Exclusion Criteria: - 1. Fitzpatrick skin types 5-6. 2. Implantable defibrillators, cardiac pacemakers, and other metal implants 3. Subjects with any implantable metal device in the treatment area 4. Pacemaker or internal defibrillator, or any other active electrical implant anywhere in the body (e.g. cochlear implant). 5. Permanent implant in the treated area, such as metal plates and screws, or an injected chemical substance. 6. Current or history of any kind of cancer, or pre-malignant moles. 7. Severe concurrent conditions, such as cardiac disorders. 8. Pregnancy or intending to become pregnant during the study and nursing. 9. Impaired immune system due to immunosuppressive diseases, such as AIDS and HIV, or use of immunosuppressive medications. 10. History of diseases stimulated by heat, such as recurrent herpes simplex in the treatment area; may be enrolled only following a prophylactic regime. 11. Poorly controlled endocrine disorders, such as diabetes. 12. Any active condition in the treatment area, such as sores, psoriasis, eczema, and rash. 13. History of skin disorders, such as keloids, abnormal wound healing, as well as very dry and fragile skin. 14. History of bleeding coagulopathies, or use of anticoagulants. 15. Use of isotretinoin (Accutane®) within six months prior to treatment. 16. Treating over tattoo or permanent makeup. 17. Excessively tanned skin from sun, tanning beds or tanning creams within the last two weeks. 18. As per the practitioner's discretion, refrain from treating any condition which might make it unsafe for the patient. |
Country | Name | City | State |
---|---|---|---|
Spain | Ocean Clinic | Marbella |
Lead Sponsor | Collaborator |
---|---|
Venus Concept |
Spain,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Treating surgical scar tissue to improve appearance as evaluated by an independent blinded reviewer at 3 months and 10 months post treatment to assess the treatment efficacy. | A blinded reviewer will analyze the photographs taken at baseline, at study visit 3 months from the study start and 10 months from study start to determine the efficacy of treatment using the 7-point General Aesthetic Improvement Scale (GAIS) where 3 is very much improved, 2 is much improved, 1 is improved, 0 is no change, -1 is worse, -2 is much worse and -3 is very much worse and the Manchester Scar Scale where the scar is evaluated by colour, surface appearance, contour, distortion and texture using a numbered scale. | 3 months and 10 months post-treatment | |
Secondary | Improvement in appearance of surgical scars at 1 and 2 months post-treatment | Evaluated by the independent reviewer using the 7-point General Aesthetic Improvement Scale (GAIS) where 3 is very much improved, 2 is much improved, 1 is improved, 0 is no change, -1 is worse, -2 is much worse and -3 is very much worse and the Manchester Scar Scale where the scar is evaluated by colour, surface appearance, contour, distortion and texture using a numbered scale. | 1 and 2 months | |
Secondary | Assessment of surgical scars at 3 and 10 months post-treatment to assess the efficacy of treatment | Patient and Observer Scar Assessment Scale (POSAS) will be used by the independent blinded reviewer to assess the efficacy of the treatment where the scar is evaluated on its vascularity, pigmentation, thickness, relief, pliability and surface area using a numbered scale. The subject will assess the scar with respect to pain, itching, color, stiffness, thickness and appearance compared to their normal skin using a numbered scale. | 3 and 10 months post treatment | |
Secondary | Subject satisfaction with treatment | Subjects will use the 5-point Likert Satisfaction scale where 4 is very satisfied, 3 is satisfied, 2 is having no opinion, 1 is unsatisfied and 0 is very unsatisfied to evaluate their satisfaction with the treatment. | 3 and 10 months post treatment |
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06013514 -
Post-market Prospective Clinical Study of Nagor Perle Mammary Implants
|
||
Completed |
NCT00753922 -
Core Gel Study of the Safety and Effectiveness of Mentor Round Low Bleed Silicone Gel-filled Mammary Prostheses
|
Phase 3 | |
Completed |
NCT01945463 -
The Effect of Breast Augmentation on the Quality of Echocardiography Test
|
N/A | |
Recruiting |
NCT05449587 -
Long-Term Effectiveness of the Motiva Implants® Round and Round Ergonomix
|
||
Completed |
NCT02302001 -
Effects of Jet Hydro Dissection in Breast Augmentation Postoperative Pain
|
N/A | |
Completed |
NCT00905645 -
Sientra Sponsored Silimed Gel-Filled Breast Implant Core Clinical Study
|
N/A | |
Completed |
NCT00756652 -
Mentor MemoryGel Post-Approval Study
|
||
Terminated |
NCT01870869 -
NATRELLE® 410 X-Style and L-Style Breast Implants Continued Access Study
|
N/A | |
Completed |
NCT00684749 -
A Pilot Study to Evaluate the BodyLogic TM System (Mentor) in Augmentation Mammaplasty
|
N/A | |
Active, not recruiting |
NCT06079086 -
Evaluation of the Clinical Evolution of Breast Increase Using Prostheses
|
N/A | |
Active, not recruiting |
NCT03386682 -
Evaluation of the Safety and Performance of ESTYME® MATRIX Round and Anatomical Breast Implants - EMMIE Study
|
N/A | |
Completed |
NCT01146275 -
A 7-year Follow up of All Subjects Incuded in Protocol 31GB0106
|
N/A | |
Completed |
NCT00663156 -
A Prospective Study of Autologous Fat Grafting for Breast Augmentation
|
N/A | |
Completed |
NCT00605670 -
Measuring Patient Satisfaction and Quality of Life Following Body Image Altering Surgery
|
N/A | |
Completed |
NCT01639742 -
European New Texture Implant Clinical Experience With Round Breast Implants
|
N/A | |
Completed |
NCT01639755 -
European New Texture Implant Clinical Experience With Shaped Breast Implants
|
Phase 4 | |
Completed |
NCT04036487 -
Effects of General Anesthesia on Quality of Recovery After Transaxillary Endoscopic Breast Augmentation
|
N/A | |
Completed |
NCT01238601 -
Upright Magnetic Resonance Imaging (MRI) Study - Breast Implant Shell Geometry and Edge Scalloping
|
N/A | |
Completed |
NCT02235285 -
Asian Outcomes of Primary Breast Augmentation
|
N/A | |
Completed |
NCT00689871 -
Safety and Effectiveness of Natrelle(TM) Cohesive Round Silicone-Filled Breast Implants
|
N/A |