Clinical Trials Logo

Clinical Trial Summary

This is a voluntary research study to find out which location in the heart a pacemaker wire is the most efficient for a patient's heart and for battery life. Patients who volunteer and are eligible for the study will be randomized to receive one of two positions for the wire to be screwed into, in addition to studying multiple positions in the heart during the pacemaker insertion. Enrolled patients will be in the study for 1 year. They will also have an Ultrasound of their heart performed to assess how the pacemaker wire is affecting their heart. Pacemakers are connected to the heart by wires that are screwed into the heart. The wires can be connected to the heart in different places, which can affect how well the heart beats over time. The typical position is at the tip of the heart. This position may cause the heart to beat inefficiently. Over time, this could lead to weakened heart muscle, irregular heart rhythm, and more hospitalizations. The heart has special muscle cells and fibers that carry electrical signals through and around the heart. An alternative spot to place the pacemaker wire is in an area where these special cells are grouped together (called the HIS bundle). The pacemaker wire can be connected to the heart at a location which may allow the heart to beat more efficiently when compared to putting the wire at traditional spots in the heart (called HIS bundle pacing). However, sometimes connecting the wire into the HIS bundle may cause the pacemaker battery to wear out faster. Physicians can also connect the pacemaker wired near the HIS bundle (called Left left Bundle bundle area pacing). The study physicians hope this will allow the heart to beat more efficiently without causing the battery to wear out faster. The study physicians would like to study how different wire positions change heart beat efficiency and how long the pacemaker battery lasts when the wires are placed in different locations. This study will connect the pacemaker wire at either the HIS Bundle or the left bundle area pacing, to see how effectively the heart pumps and how much battery is being used.


Clinical Trial Description

This is a single center, open label, prospective randomized pilot study to evaluate the capture threshold of His Bundle versus left bundle area pacing. Secondary analysis will focus on changes in left ventricular performance and mechanical synchrony. Symptomatic bradyarrhythmias are effectively treated with cardiac pacemakers.The amount of pacing by the lead positioned in the bottom chamber of the heart at traditional sites such as the right ventricular apex have been associated with increased rates of atrial fibrillation, heart failure, and mortality. Traditional pacing sites result in cardiac electromechanical dyssynchrony, for which alternate pacing sites to minimize these untoward effects have been sought. HIS bundle pacing, which utilizes a patient's native conduction, has demonstrated improved electrical synchrony and left ventricular function when compared to traditional pacing at the tip of the bottom chamber. Barriers to wide spread application to this technique include the His bundle anatomic location and its attendant difficulties associated with implant, as well as higher capture thresholds leading to decreased battery duration of the pacemaker. An alternative to HIS bundle pacing is placing the lead just past the HIS bundle area, which is further in the heart, and to actively fixate the lead into the interventricular septum. This is referred to as Left Bundle Pacing, as it may electrically capture the left bundle, which would simulate a patient's native conduction. The researchers will evaluate the two different pacing sites (HIS bundle and Left Bundle area sites) to determine how effectively the heart pumps with each pacing site. Patients requiring pacemaker implant will be screened for study eligibility and approached for informed consent. Baseline assessments including echocardiogram and ECG will be obtained. A standard of care echo done within 3 months of the procedure will be used as the baseline echo. Once enrolled, the researchers will randomize patients to one of two arms. One arm will fixate the ventricular pacemaker lead to the HIS bundle area while the other arm will have the leads fixed into the left bundle area. The pacemaker wires will be connected in accordance with randomization group. The day after the procedure, a chest x-ray, EKG and pacemaker evaluation will be performed. An echocardiogram will be obtained at 3 months post procedure. At 6 and 12 months post procedure, EKG rhythm strips will be obtained from patients' standard of care remote pacemaker monitoring systems. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04093414
Study type Interventional
Source William Beaumont Hospitals
Contact
Status Terminated
Phase N/A
Start date October 7, 2019
Completion date February 22, 2022

See also
  Status Clinical Trial Phase
Completed NCT03922386 - Safety and Electrical Performances of XFINE Leads N/A
Completed NCT03294018 - Heart Rate Changes Following the Administration of Sugammadex
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Not yet recruiting NCT05440071 - PoSt-market Assessment on Safety and Performance of J-sHAPed xFINE Lead
Completed NCT02153242 - The Effects of Selective Site Right Ventricular Pacing
Recruiting NCT01825473 - Study of Erythromycin in GER-Associated Apnea of the Newborn N/A
Completed NCT00950287 - Detection of Neonatal Bradycardia N/A
Completed NCT00721136 - Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation N/A
Completed NCT00286858 - Beluga - Clinical Observations of Automatic Algorithms for Cardiac Pacing
Completed NCT00158925 - The EASYTRAK EPI Clinical Investigation Phase 3
Completed NCT00180557 - Austria Study - Analysis of Difference Between Active and Passive Fixation Leads Phase 4
Completed NCT01076348 - Model 4965 Post-Approval Study
Completed NCT04198220 - BIO|STREAM.ICM Obesity
Recruiting NCT05298748 - The Effect of Womb Recordings on Maturation of Respiratory Control in Preterm Infants N/A
Recruiting NCT04353960 - The Alaska Oculocardiac Reflex Study
Completed NCT03786640 - Abbott Brady 3T MRI PMCF
Recruiting NCT05932602 - AVEIR DR Coverage With Evidence Development (CED) Study
Recruiting NCT05935007 - Aveir DR Real-World Evidence Post-Approval Study
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)
Recruiting NCT03008291 - His Bundle Pacing in Bradycardia and Heart Failure