Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00508196
Other study ID # 190906ver3
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date November 2006
Est. completion date July 2007

Study information

Verified date March 2019
Source University of Dundee
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Pacing from the right ventricle (as is current practice in patients implanted with permanent pacemakers for bradycardia), has been associated with worse outcomes particularly in heart failure patients. Recent clinical trials suggest that chronic right ventricular pacing (VP) is associated with worsening heart failure, increased strokes and atrial fibrillation. Hemodynamically, right VP results in delayed activation and contraction of the LV which can give rise to functional mitral regurgitation, shortened diastolic filling time and thus reduced coronary filling, as well as abnormal arterial pulsatile flow. The mechanisms for the deleterious effects of right VP in heart failure patients have not been previously investigated. Our aim of this study is therefore to investigate the hemodynamic effects of right VP in stable heart failure patients in terms of exercise cardiac output (CO, an important measure of myocardial function and prognosis), as well as endothelial function which may be deranged as a result of abnormal arterial pulsatile flow.


Description:

Study Aims The aim of this study is to investigate the effect of right ventricular pacing on CO at rest and exercise, and on endothelial function and B-type natriuretic peptide, BNP, in patients with heart failure.

Methods: Thirty patients with dual chamber pacemakers for sinus node disease will be recruited: 15 controls with normal LV function and 15 with stable impaired LV function (ejection fraction <40%). The pacemaker will be programmed to pace to back-up pacing at 55bpm in the atrial only (AAI, no right VP) for one week (baseline); and than programmed to overdrive pacing at 70-80bpm, randomised to either to dual chamber, DDD (sequential atrial and ventricular pacing) with a short AV delay (to ensure maximal right VP) or AAI (no RV pacing), for 1 week. There will be a crossover after a 1 week washout at backup AAI pacing at 55 bpm. Resting and exercise CO will be measured at the end of each pacing mode intervention using the Inocor system (a validated non invasive method of CO measurement, using inhaled inert gas equilibriums). Endothelial function will be measured non-invasively at the same time points, as will plasma BNP, a measure of LV strain. Patients with unstable heart failure or angina will be excluded.

Study Endpoints: Rest and exercise CO; and endothelial function and BNP with and without RV pacing, in patients with preserved and impaired LV function.


Recruitment information / eligibility

Status Completed
Enrollment 22
Est. completion date July 2007
Est. primary completion date July 2007
Accepts healthy volunteers No
Gender All
Age group 21 Years to 85 Years
Eligibility Inclusion Criteria:

- Dual chamber pacemaker

- Intact AV node function

Exclusion Criteria:

- Unstable angina, heart failure

- Inability to exercise

Study Design


Related Conditions & MeSH terms


Intervention

Other:
RVP-min
DDD pacing with long AV delay
RVP-max
DDD pacing with short AV delay

Locations

Country Name City State
United Kingdom Ninewells Hospital and medical School Dundee

Sponsors (1)

Lead Sponsor Collaborator
University of Dundee

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Endothelial Function Assessed by Flow Mediated Vasodilatation Flow mediated vasodilatation as measured by reactive hyperaemia peripheral arterial tonometry signal using EndoPAT software, Itamar.
A post-occlusion to pre-occlusion ratio is calculated by the EndoPAT software, providing the EndoPAT index (EnFI)
1 week
Secondary B-type Natriuretic Pepetide 1 week
Secondary Cardiac Output measured at peak exercise on a standard exercise bicycle, measured non-invasively using the inert gas rebreathing technique (Innocor, Innovision A/S, Odense, Denmark). 1 week
See also
  Status Clinical Trial Phase
Completed NCT03922386 - Safety and Electrical Performances of XFINE Leads N/A
Completed NCT03294018 - Heart Rate Changes Following the Administration of Sugammadex
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Not yet recruiting NCT05440071 - PoSt-market Assessment on Safety and Performance of J-sHAPed xFINE Lead
Completed NCT02153242 - The Effects of Selective Site Right Ventricular Pacing
Recruiting NCT01825473 - Study of Erythromycin in GER-Associated Apnea of the Newborn N/A
Completed NCT00950287 - Detection of Neonatal Bradycardia N/A
Completed NCT00721136 - Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation N/A
Completed NCT00286858 - Beluga - Clinical Observations of Automatic Algorithms for Cardiac Pacing
Completed NCT00158925 - The EASYTRAK EPI Clinical Investigation Phase 3
Completed NCT00180557 - Austria Study - Analysis of Difference Between Active and Passive Fixation Leads Phase 4
Completed NCT01076348 - Model 4965 Post-Approval Study
Completed NCT04198220 - BIO|STREAM.ICM Obesity
Recruiting NCT05298748 - The Effect of Womb Recordings on Maturation of Respiratory Control in Preterm Infants N/A
Recruiting NCT04353960 - The Alaska Oculocardiac Reflex Study
Terminated NCT04093414 - Left Bundle Area Versus Selective His Bundle Pacing N/A
Completed NCT03786640 - Abbott Brady 3T MRI PMCF
Recruiting NCT05932602 - AVEIR DR Coverage With Evidence Development (CED) Study
Recruiting NCT05935007 - Aveir DR Real-World Evidence Post-Approval Study
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)