This study is a long-term, prospective, and controlled evaluation of the mechanical dyssynchrony induced by right ventricular apical pacing, both in acute (spontaneous and stimulated) and chronic (12 and 24 months); the study also evaluates the benefit of an alternative pacing site through measures of dyssynchrony in acute and chronic.


Clinical Trial Description

Permanent cardiac pacing plays an important role in cardiac disease management. Since early studies on right ventricular pacing, apex has been the preferred implant site for transvenous endocardial ventricular leads for several reasons: ease of placement, lead stability as well as the design characteristics of the electrode and the fixation system.

It is now also accepted, however, that right ventricle pacing causes a long term deterioration of left ventricular function through complex effects, both at the structural level of the heart wall and at the hemodynamic level in left ventricular load conditions. It is possible that this deterioration is due to a dyssynchrony of contraction induced by pacing at the right ventricular apex. Some authors suggest to pace the right ventricle at alternative sites, i.e. the medium septum (RVS) region, to guarantee a more physiological activation pattern, especially in patients expected to receive high pacing percentages.

However, unequivocal evidences that stimulation of the right ventricular septum is more physiological than the apical pacing are still missing.

Nonetheless, it should be noted that, although a number of studies refer to RV septum as the alternative site for pacing , poor attention has been paid to the unambiguous definition of RV septum region itself. A clear definition and a proper evaluation of the alternative site is therefore important.

Furthermore, from a procedural point of view, it has been demonstrated that acute and chronic electrical performances of the leads positioned at alternative sites, in particular in the region of mid septum, are equivalent to those of the leads positioned at the apical site.

The purpose of this study is to perform a comprehensive assessment of the electrical and mechanical measures obtained by pacing standard RV site (Right ventricular apex, RVA) and alternative RV site (right ventricular septum, RVS). Specifically, the two pacing sites will be compared in terms of electrical dyssynchrony, as assessed by ECG criteria, and in terms of mechanical dyssynchrony, as assessed by echocardiographic criteria.

The primary end point of the study is defined through the evaluation of dyssynchrony measured both in spontaneous rhythm (Vs) and paced rhythm (Vp). The delay between the time to peak systolic velocity of the septum and the LV free wall will be used to define the degree of dyssynchrony; this measurement will be obtained by TDI echocardiographic technique.

Patients will receive any commercially available dual-chamber implantable pacemakers, according to current standard indications. At the end of the implantation and at follow-up visits (12 and 24 months) device programming will follow the clinical practice of the center. ;


Study Design

Allocation: Non-Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Prevention


Related Conditions & MeSH terms


NCT number NCT01647490
Study type Interventional
Source Ospedale Santa Maria di Loreto Mare
Contact
Status Recruiting
Phase N/A
Start date April 2012
Completion date July 2015

See also
  Status Clinical Trial Phase
Completed NCT03922386 - Safety and Electrical Performances of XFINE Leads N/A
Completed NCT03294018 - Heart Rate Changes Following the Administration of Sugammadex
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Not yet recruiting NCT05440071 - PoSt-market Assessment on Safety and Performance of J-sHAPed xFINE Lead
Completed NCT02153242 - The Effects of Selective Site Right Ventricular Pacing
Recruiting NCT01825473 - Study of Erythromycin in GER-Associated Apnea of the Newborn N/A
Completed NCT00950287 - Detection of Neonatal Bradycardia N/A
Completed NCT00721136 - Randomized Study of the Use of Warfarin During Pacemaker or ICD Implantation in Patients Requiring Long Term Anticoagulation N/A
Completed NCT00286858 - Beluga - Clinical Observations of Automatic Algorithms for Cardiac Pacing
Completed NCT00158925 - The EASYTRAK EPI Clinical Investigation Phase 3
Completed NCT00180557 - Austria Study - Analysis of Difference Between Active and Passive Fixation Leads Phase 4
Completed NCT01076348 - Model 4965 Post-Approval Study
Completed NCT04198220 - BIO|STREAM.ICM Obesity
Recruiting NCT05298748 - The Effect of Womb Recordings on Maturation of Respiratory Control in Preterm Infants N/A
Recruiting NCT04353960 - The Alaska Oculocardiac Reflex Study
Terminated NCT04093414 - Left Bundle Area Versus Selective His Bundle Pacing N/A
Completed NCT03786640 - Abbott Brady 3T MRI PMCF
Recruiting NCT05935007 - Aveir DR Real-World Evidence Post-Approval Study
Recruiting NCT05932602 - AVEIR DR Coverage With Evidence Development (CED) Study
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)