Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03078985
Other study ID # 2016-IMR
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date March 30, 2017
Est. completion date January 15, 2019

Study information

Verified date February 2019
Source University of Leipzig
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this clinical study is to assess the safety and performance of the Vision-MR Ablation Catheter, the primary safety endpoint will measure the rate of serious adverse events related to the device or procedure; the primary performance endpoint will measure the acute success rate defined as the demonstration of bidirectional cavo-tricuspid isthmus block after radiofrequency application in the cavo-tricuspid isthmus; the secondary performance endpoint will measure the chronic success rate defined as the freedom of recurrence of type 1 atrial flutter at three months post-ablation procedure. The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. The study population will consist of adult patients requiring ablation for type I atrial flutter.

This is the follow-up study to NCT02699034.


Description:

The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. 35 subjects subjects meeting inclusion/exclusion criteria will participate in the study. This study requires the use of investigational products from two independent manufacturers: Imricor and Philips. Imricor has developed the ablation catheter with related accessory cables and electrophysiology (EP) recorder/stimulator system. Philips has developed an image guidance and mapping system that is compatible with the Imricor products.

The Vision-MR Ablation Catheter will be used in conjunction with the following investigational products: Vision-MR Ablation Cable Set, Vision-MR Diagnostic Cable, the interventional MRI Suite (iSuite) image guidance and mapping system, and a dStream Interface (dSIF-FE). With the exception of iSuite and dSIF-FE, which are manufactured by Philips, Imricor will provide all investigational devices used in the study.

Each procedure will require two single-use Vision-MR Ablation Catheters and one each of the two single-use accessory catheter cables.

Ablation for the treatment of arrhythmia is an inherently complex procedure. Use of the investigational products listed above under MR guidance is an emerging approach to performing the interventional electrophysiology procedure.

The study population will consist of adult patients requiring ablation for type I atrial flutter.

Study subjects will require a follow-up visit or telephone call at seven days post procedure. Accordingly, the expected total study duration is approximately 9 months with study start planned for February 2017.

This is the follow-up study to NCT02699034 which was terminated early based on a recommendation by the oversight authority. The study device (Vision-MR ablation catheter) has been improved and the EP recorder/stimulator is now CE-marked.


Recruitment information / eligibility

Status Completed
Enrollment 36
Est. completion date January 15, 2019
Est. primary completion date December 11, 2017
Accepts healthy volunteers No
Gender All
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria:

- First time indication for ablation for type I atrial flutter.

- Patients willing and able (mentally and physically capable per physician's discretion) to understand the investigational nature, potential risks and benefits of the study and able to provide written informed consent to participate in the study and agree to comply with follow-up visits and evaluation

- Patients able to receive anticoagulation therapy to achieve adequate anticoagulation

Exclusion Criteria:

- Contraindication for MRI diagnostic exam

- A cardiac ablation or cardiac surgery within 180 days prior to enrollment

- Documented intracardiac thrombus, tumor, bleeding, clotting or other abnormality that precludes catheter introduction and placement

- Myocardial infarction within 60 days prior to enrollment

- Current unstable angina

- History of cerebrovascular event (within 180 days prior to enrollment)

- Patients with an ejection fraction less than or equal to 35% within 90 day prior to enrollment

- Permanent leads in or through the right atrium

- Clinically significant structural heart disease (including tricuspid valve regurgitation, tricuspid valve stenosis or other congenital heart disease) that would preclude catheter introduction and placement, as determined by the Investigator

- Uncompensated congestive heart failure (NYHA Class III or IV)

- Arrhythmia is secondary to electrolyte imbalance, thyroid disease, or other reversible or non-cardiovascular cause

- Known sensitivity to heparin or warfarin

- Active or systemic infection

- Any other significant uncontrolled or unstable medical condition (including but not limited to hypertension and diabetes)

- contraindication for conventional ablation procedure know allergy against radiocontrast agents renal insufficiency with glomerular filtration rate < 30ml/min/1,73m2

- Women who are pregnant or plan to become pregnant within the course of their participation in the investigation or who are breastfeeding

- Life expectancy of less than 12 months

- Patients with prosthetic valves

- Contraindicated for transfemoral venous access

- Older than 75 years

- Current enrollment in any other clinical investigation

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
ablation for typical atrial flutter
Typical atrial flutter is treated by catheter ablation.
Device:
catheter ablation with study device
The study device is used inside the MRI environment to localize the cavotricuspid isthmus (CTI). The CTI is then treated with radiofrequency energy to achieve complete isthmus block.

Locations

Country Name City State
Germany Heart Center Leipzig Leipzig Saxony

Sponsors (4)

Lead Sponsor Collaborator
University of Leipzig Heart Center Leipzig - University Hospital, Imricor Medical System, Philips Healthcare

Country where clinical trial is conducted

Germany, 

References & Publications (2)

Grothoff M, Gutberlet M, Hindricks G, Fleiter C, Schnackenburg B, Weiss S, Krueger S, Piorkowski C, Gaspar T, Wedan S, Lloyd T, Sommer P, Hilbert S. Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases. Eur Radiol. 2017 May;27(5):1954-1962. doi: 10.1007/s00330-016-4560-7. Epub 2016 Aug 23. — View Citation

Hilbert S, Sommer P, Gutberlet M, Gaspar T, Foldyna B, Piorkowski C, Weiss S, Lloyd T, Schnackenburg B, Krueger S, Fleiter C, Paetsch I, Jahnke C, Hindricks G, Grothoff M. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series. Europace. 2016 Apr;18(4):572-7. doi: 10.1093/europace/euv249. Epub 2015 Aug 27. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Number of patients with bidirectional cavo-tricuspid isthmus block after intervention Acute success defined as the demonstration of the established electrophysiological endpoint (e.g. bidirectional cavo-tricuspid isthmus block after radiofrequency application in the cavo-tricuspid isthmus) with the investigational device. Historically, the acute success rate for RF ablation of type I atrial flutter is 85%. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S achieving success, the percentage, represented as P, will be calculated as P = 100*S/N. 9 months
Primary Number of patients with periinterventional serious adverse events The primary safety endpoint is the rate of serious adverse events (SAEs) related to the device or procedure assessed at the 7-day follow-up. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S experiencing an SAE related to the device or procedure, the percentage, represented as P, will be calculated as P = 100*S/N. 9 months
Primary Number of patients with freedom from recurrence from type I atrial flutter 3 months (chronic success rate) after ablation (study procedure). The primary chronic performance endpoint is the chronic success rate defined as freedom from recurrence of type 1 atrial flutter at 3 months post procedure. Freedom of recurrence of type I atrial flutter is assessed using symptom survey, ECG and echocardiogram data. This will be evaluated separately for all subjects treated with the device and for all subjects that achieved acute success (defined by the primary acute performance endpoint). 9 month
Secondary Number of patients with freedom from recurrence from type I atrial flutter 6 months after ablation (study procedure). The secondary performance endpoint is the chronic success rate defined as freedom from recurrence of type 1 atrial flutter at 6 months post procedure. Freedom of recurrence of type I atrial flutter is assessed using symptom survey, ECG and echocardiogram data. This will be evaluated separately for all subjects treated with the device and for all subjects that achieved chronic success (defined by the primary chronic acute performance endpoint). 9 month
See also
  Status Clinical Trial Phase
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Terminated NCT02317029 - Comparison of Oxygen Interventions and Defibrillator Efficiency N/A
Recruiting NCT01563848 - Cryoablation in Patients With Atrial Flutter Phase 2
Completed NCT01229254 - Evaluate the Pharmacokinetics and Safety of MK-4448 in Participants With Nonvalvular Atrial Fibrillation or Atrial Flutter Phase 2
Completed NCT00839657 - Clarification of Optimal Anticoagulation Through Genetics Phase 3
Completed NCT02065388 - Pharmacogenetic Dosing of Warfarin Phase 3
Completed NCT00232232 - Use of Fish Oils to Prevent Atrial Mechanical Stunning and Atrial Remodeling Due to Atrial Arrhythmia Phase 4
Completed NCT04884100 - enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening N/A
Completed NCT05468281 - RAFF5 Proposal: Improve the Quality and Safety of Patients Seen in the Emergency Department for Acute Atrial Fibrillation and Flutter
Completed NCT03627143 - Decreasing Hospital Admissions From the ED for AAFF N/A
Completed NCT02917538 - A Randomized Trial of Contact Force in Atrial Flutter Ablation N/A
Enrolling by invitation NCT05903313 - A Study to Evaluate Accuracy and Validity of the Chang Gung ECG Abnormality Detection Software
Recruiting NCT05755074 - Ablation of Typical Right Atrial Flutter N/A
Recruiting NCT05883631 - RESOLVE-AF: Clinical Evaluation of the Ablacath™ Mapping Catheter and Ablamap® System Utilizing Electrographic Flow (EGF) Mapping to Resolve Extra-PV Sources of Atrial Fibrillation and Guide Ablation Therapy. N/A
Recruiting NCT03272620 - Atrial Fibrillation at the Viennese University Emergency Department N/A
Completed NCT02810938 - MIFI Flutter Registry - Ablation of Atrial Flutter With IntellaTip Sensor Technology
Recruiting NCT02591875 - Atrial Flutter Ablation in a Real World Population N/A
Completed NCT01914497 - Dipole Density Mapping of Typical Atrial Flutter N/A
Completed NCT02268799 - High Sensitivity Troponin T Levels Following DC Cardioversion for Atrial Fibrillation / Atrial Flutter N/A
Active, not recruiting NCT01976507 - Use of Dabigatran Etexilate to Prevent Stroke and Thromboembolism Phase 4

External Links