Astigmatism Clinical Trial
Official title:
Diurnal Changes of the Cornea - a Pilot Study
Aim of this study is to gain a better understanding of the diurnal changes of the cornea to improve toric IOL power calculations.
Higher patient expectations concerning unaided visual acuity after cataract surgery has led
to an increase in use of toric intraocular lenses (toric IOLs) for the correction of corneal
astigmatism. Although it was shown that toric IOLs significantly reduce astigmatism, there is
still some difficulty in predicting the remaining astigmatism correctly. The main source of
error appears to be the pre-operative measurement of the cornea. However, it is questionable,
if this error derives from a measurement error due to the imprecise measurement technique, or
natural diurnal changes of the cornea. Additionally, measurements of the cornea pose several
challenges: different corneal biometry devices cannot be used interchangeably and it is
difficult to decide, which device is measuring the cornea correctly as there is no gold
standard.
Especially, in eyes with small corneal astigmatism the error increases. Recently it was shown
that the astigmatism meridian was on median 9° off for corneas with 1.0D of astigmatism and
only 4° for corneas with 2.0D of astigmatism. Similar findings were observed by Shammas et
al. Norrby furthermore showed that 5% of all corneas show more than 0.5D of fluctuations
between measurements at different (post-operative) time-points. The reasons are not explored,
but diurnal changes, temperature and humidity potentially influencing the tear film, as well
as pupil size and asphericity of the cornea could play a role. Read and Collins observed
diurnal changes of corneal radii within 24 hours, but in their study only young healthy
volunteers were included and only one measurement device (Scheimpflug imaging, Pentacam HR)
was used. Lau and Pye and Shen et al. measured the diurnal changes of the cornea, but no data
concerning corneal radii were reported. Harper et al. observed diurnal changes of the central
corneal thickness. However, none of these studies investigated on diurnal changes of the
corneal radii in the elderly population. Aim of this study is to gain a better understanding
of the diurnal changes of the cornea to improve toric IOL power calculations.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT04536571 -
Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses
|
N/A | |
Completed |
NCT05039112 -
Clinical Comparison of 2 Daily Disposable Toric Soft Contact Lenses
|
N/A | |
Completed |
NCT04613882 -
Quantification of the Visual Benefits of Soft Toric Contact Lenses Compared to Soft Spherical Contact Lenses
|
N/A | |
Recruiting |
NCT05611294 -
Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction
|
N/A | |
Completed |
NCT05633082 -
A Clinical Performance of Two Soft Toric Contact Lenses
|
N/A | |
Not yet recruiting |
NCT05506553 -
Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision
|
N/A | |
Not yet recruiting |
NCT05561296 -
Astigmatism Management With Iris-registration Guided Corneal Relaxing Incisions or Toric IOLs During Cataract Surgery
|
N/A | |
Completed |
NCT02847169 -
Clinical Performance of Toric Hydrogel Contact Lenses Following One Week of Daily Wear
|
N/A | |
Recruiting |
NCT02618018 -
Clinical Evaluation of Efficacy and Stability of AT TORBI 709M 4-haptic Toric IOL in Cataract Surgery
|
N/A | |
Completed |
NCT02555098 -
A Bilateral Dispensing Clinical Trial of an Sapphire Lens Against Senofilcon A Toric for Astigmatism Lens
|
N/A | |
Completed |
NCT02550353 -
Changes Between Lenticule Extraction and Femtosecond Laser-assisted Laser in Situ Keratomileusis
|
N/A | |
Completed |
NCT02423109 -
Bilateral Dispensing Study of Fanfilcon A Toric Versus Enfilcon A Toric Lenses
|
N/A | |
Completed |
NCT02551796 -
Early Changes Among FLEx, LASIK and FS-LASIK
|
N/A | |
Completed |
NCT02248766 -
Clinical Performance of Habitual Wearers of Avaira Toric When Refitted With Clariti Toric Lenses
|
N/A | |
Completed |
NCT01857102 -
Toric Eye Strain and Stability Study
|
N/A | |
Completed |
NCT01965288 -
Clinical Performance of Biofinity Toric Versus Air Optix for Astigmatism
|
N/A | |
Completed |
NCT02624791 -
Evaluating and Improving Functional Driving Vision of Patients With Astigmatism
|
N/A | |
Withdrawn |
NCT01680354 -
Surgical Correction of Astigmatism
|
N/A | |
Completed |
NCT01207466 -
Evaluation of Two Daily Disposable Contact Lenses for Wearers With Astigmatism
|
N/A |