Clinical Trials Logo

Clinical Trial Summary

The primary purpose of this study is to evaluate the clinical performance of the Attune S+ knee primarily based on evaluation with use of Oxford Knee Score. The NexGen TKR will be used as reference standard. The second aim is to study component migration with model-based RSA in a subgroup of patients with model-based RSA and to compare these measurements with migration measurements with use of CT-based migration measurements. The investigators hypothesis is that the results two years after insertion of these two TKR designs will be about equal.


Clinical Trial Description

The Attune knee was launched in 2012. From a clinical point of view some studies indicate superior clinical performance of the Attune when compared to the PFC. Carey and Harty operated 21 patients with both the Attune and the POFC Sigma knees. At six months' clinical scores were superior for the Attune side as was range of movement. Ranawat 2017, matched 100 Attune to 100 PFC Sigma knee operations based on age, gender, side and BMI but found no difference in clinical results after 2 years. Bonutti reviewed three hospital databases and described 2 cases with loosening of the tibial component due to debonding between the cement and the implant, but the total material from which these cases were collected was not known or mentioned. Turgeon studied the fixation of 30 consecutive cases operated with the Attune knee and observed a mean maximum total point motion of 0.08 mm between 12 and 24 months, which suggests an acceptably low risk of medium to long-term failure due to aseptic loosening. Staats evaluated incidence of radiolucent lines in 276 Attune and 253 PFC Sigma TKRs up to one year after operation and observed a higher incidence in the former group. In the last report from NJR from 2020, the 5-year revision rate of the Attune FB knee is 2.71 (2.32-3.17), which is slightly above average (2.23, 2.20-2.26). In the Australian registry from 2020 the corresponding cumulative percent revision rate of cemented Attune CR is 3.0 % (2.7 - 3.5) at 5 years. In an ongoing study the investigators have randomized 95 knees with knee osteoarthritis to either become operated with an Attune knee (n=49) or a PFC knee (n=46). Preliminary results at one year show almost equal results when evaluated in terms of Oxford Knee or Forgotten Joint Scores. NexGen metal-backed tibia is the most commonly used total knee prosthesis in Sweden. Its revision rate is one of the lowest observed in the Swedish Register. The 5 years survival in the report from NJR from 2020 is 2.1% (2.05 - 2.21) and in the report from the Australian register it is about equal (2.0; 1.9 - 2.2). The Australian Register also present survival at 19 years amounting to 5.7% (4.7 - 6.9) being the lowest cumulative revision of those specific cemented TKRs accounted for with that long follow up. In 2017 DePuy launched the Attune S+ tibial components in order to address the potential problem of loosening between the cement and the tibial tray. If and if so, to what extent this modification will change the clinical outcome of TKRs operated with this implant is not known. Based on the high survival rate of the in Sweden frequently used NexGen TKR a comparative study between the Attune S+ and the NexGen TKRs would provide an important benchmark for the performance of the Attune S+ knee. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05464641
Study type Interventional
Source Göteborg University
Contact Roland Zügner, PhD
Phone 0703101863
Email roland.zugner@gmail.com
Status Recruiting
Phase N/A
Start date January 1, 2022
Completion date December 31, 2024

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05666479 - CGM Monitoring in T2DM Patients Undergoing Orthopaedic Replacement Surgery
Recruiting NCT05002387 - Diagnostic Knee Needle Arthroscopy in Predicting Unicompartmental Knee Osteoarthritis N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03008967 - A Study of Patients Undergoing Total Knee and Hip Arthroplasty at a Regional Hospital in Denmark N/A
Withdrawn NCT02255877 - ZIPS Study - Zip Incision Approximation vs. STAPLE Phase 4
Completed NCT02642731 - Kidney Biomarkers of Acute Kidney Injury in Patients With Knee Arthroplasty N/A
Completed NCT02525588 - Polyethylene Wear Study on the Triathlon Total Knee Prosthesis N/A
Completed NCT01799772 - The Feasibility of a Comprehensive Behavioral Intervention in Patient Post TKA Phase 1/Phase 2
Completed NCT02520531 - Scorpio Posterior Stabilised (PS) vs Scorpio NRG ("Energize") PS - Total Knee Arthroplasty N/A
Completed NCT03183856 - Comparison of Ambulatory and Functional Improvement by Morning Walk N/A
Completed NCT03569397 - Music Therapy Versus Control for Total Knee Arthroplasty N/A
Terminated NCT02711592 - Pharmacogenomics Information in Enhancing Post-operative Total Joint Replacement Pain Management: a Pilot Study N/A
Completed NCT03145493 - Effect of Suction Drains in Total Knee Arthroplasty With Tranexamic Acid N/A
Terminated NCT05602701 - Preoperative Prediction of Postoperative Physical Function
Recruiting NCT03570944 - Postoperative Outcomes Within an Enhanced Recovery After Surgery Protocol (POWER2)
Completed NCT02773537 - Motor-Sparing Peripheral Nerve Blockade Facilitates Mobility Post Total Knee Arthroplasty: A Randomized Controlled Trial N/A
Withdrawn NCT02553122 - The Combined Efficacy of Evicel and Tranexamic Acid on Total Knee Arthroplasty Phase 3
Recruiting NCT02385383 - An Intravenous Iron Based Protocol for Preoperative Anaemia in Hip and Knee Surgery - An Observational Study N/A
Terminated NCT02155712 - Triathlon Tritanium Knee Outcomes Study N/A
Completed NCT02121392 - Epidural Catheter With or Without Adductor Canal Nerve Block for Postoperative Analgesia Following Total Knee Arthroplasty N/A