Clinical Trials Logo

Clinical Trial Summary

Use of the closure device in patient with percutaneous transfemoral aortic valve replacement


Clinical Trial Description

The advent of endovascular, transcatheter aortic valve replacement (TAVR), and mechanical circulatory support has offered new, minimally invasive therapeutic options that are rapidly becoming standard of care. These percutaneous transfemoral interventions require large-bore catheters and have created challenges for femoral arterial access management. Current approaches include surgical cut-down with arterial puncture under direct vision, and suture-based "pre-closure." Surgical cut-down is associated with longer procedural time, increased patient discomfort, deeper anesthesia, risk of wound complications including infection, and slower ambulation. The pre-closure technique overcomes many of the disadvantages of surgical cut-down but can be technically demanding, time consuming, and associated with a significant failure rate. Recent randomized TAVR trials have reported major vascular complications in 6% to 8% . Furthermore, a study on the 2 suture-based closure techniques for management of TAVR access reported a 20% vascular complication rate despite being used by experienced operators . Currently, the majority of access site complications result from failed arteriotomy closure . The percutaneous MANTA Vascular Closure Device (VCD) (Essential Medical Inc., Malvern, Pennsylvania) is a novel collagen-based technology dedicated to closure of largebore arteriotomies . The MANTA VCD underwent prospective multicenter evaluation for Conformitä Europäenne (CE) mark approval in the first detailed report of outcomes achieved with a dedicated large-bore vascular closure device Contrary to the aforementioned TAVR procedures, mechanical circulatory support therapy can be extended up to several days on the intensive care ward. Data on such delayed closure with is lacking. This registry is therefore aimed to document the initial experiences of delayed closure of a femoral large bore access with vascular closure devices in patients with an TAVR device. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05662748
Study type Observational [Patient Registry]
Source RWTH Aachen University
Contact
Status Completed
Phase
Start date January 20, 2020
Completion date March 30, 2021

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease