Aortic Valve Stenosis Clinical Trial
Official title:
A Prospective, Multinational, Multicentre, Open-label, Randomised, Non-inferiority Trial to Compare Safety and Effectiveness of Meril's Myval Transcatheter Heart Valve (THV) Series vs. Contemporary Valves (Edwards's Sapien THV Series and Medtronic's Evolut THV Series) in Patients With Severe Symptomatic Native Aortic Valve Stenosis
The primary objective of this study (LANDMARK) is to compare the safety and effectiveness of the Myval THV Series with Contemporary Valves (Sapien THV Series and Evolut THV Series) in patients with severe symptomatic native aortic valve stenosis. This study will be done in total 768 subjects (384:384, Myval THV Series vs. Contemporary Valves) The randomisation will be carried out with an allocation ratio of 1:1 between Myval THV Series vs. Contemporary Valves (Sapien THV Series and Evolut THV Series)
LANDMARK Trial is a prospective, randomised, multinational, multicentric, open-label non-inferiority trial of total 768 subjects (384:384, Myval THV Series vs. Contemporary Valves) with severe symptomatic native aortic valve stenosis via transfemoral approach. - Device sizes applicable for the Myval THV Series: 20 mm, 21.5 mm, 23 mm, 24.5 mm, 26 mm, 27.5 mm, and 29 mm diameter. - Device sizes applicable for the Sapien 3 THV Series: 20 mm, 23 mm, 26 mm, and 29 mm diameter. - Device sizes applicable for the Evolut THV Series: 23 mm, 26 mm, 29 mm, and 34 mm diameter. A non-randomised nested registry will be conducted to include patients requiring extra-large size of Myval THV series (XL Nested Registry) - Device sizes applicable for the XL Nested Registry: 30.5 mm and 32 mm. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|