Clinical Trials Logo

Clinical Trial Summary

Until a few years ago the only interventional option available for severe aortic stenosis was surgical aortic valve replacement. About a decade ago, a novel percutaneous technique was applied for the first time in humans, the transcatheter aortic valve implantation (TAVI). Initially this procedure was reserved for those patients deemed too high risk for surgical intervention. As technology progressed in this domain, the indication for TAVI expanded to a broader population of patient with severe aortic stenosis. To-date there are no long-term data for mortality and this is the central question this study will explore in correlation with haemodynamic parameters. Essentially, this study will explore the effect of TAVI in the long term. All patients that had a TAVI within the RBH&HH NHS Foundation Trust between January 2008 and December 2017 will be included in the study. This is a retrospective study.


Clinical Trial Description

Aortic valve stenosis is the most prevalent valvulopathy in the developed world countries. Until a few years ago the only interventional option available for severe aortic stenosis was surgical aortic valve replacement. About a decade ago, a novel percutaneous technique was applied for the first time in humans, the transcatheter aortic valve implantation (TAVI) as a keyhole procedure. Initially this procedure was reserved for those patients deemed too high risk for surgical intervention. As technology progressed in this domain, the indication for TAVI expanded to a broader population of patient with severe aortic stenosis. As the experience broadens there are no long-term data for mortality and this is the central question this study will explore in correlation with haemodynamic parameters. Essentially, this study will explore the effect of TAVI in the long term. All patients that had a TAVI within the RBH&HH NHS Foundation Trust between January 2008 and December 2017 will be included in the study. This is a retrospective study and will not change anything in the patients' standard of care. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03769545
Study type Observational
Source Royal Brompton & Harefield NHS Foundation Trust
Contact
Status Completed
Phase
Start date January 1, 2008
Completion date December 31, 2017

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease