Clinical Trials Logo

Clinical Trial Summary

Balloon predilatation of the aortic valve has been regarded as an essential step during the transcatheter aortic valve implantation (TAVI) procedure. However, recent evidence suggested that aortic valvuloplasty may be harmful and that high success rate may be obtained without prior dilatation of the valve. We hypothesize that TAVI performed without predilatation and using new generation balloon expandable prothesis is associated with a better net clinical benefit in comparison with procedure performed with pre dilatation.


Clinical Trial Description

Background Transcatheter aortic valve implantation (TAVI) is now the standard of care for inoperable patients with severe symptomatic aortic stenosis and an accepted alternative to surgery for high-risk patients. Despite a high procedure success rate (> 95%), TAVI remained associated with complications directly related to the technique (stroke, aortic regurgitation, vascular access bleeding) or to co morbidities frequently associated with aortic valve disease in elderly and frail patients. Reducing periprocedural complications is thereby the key for the future use of TAVI in lower-risk patients. Methods/design The transcatheter aortic valve implantation without prior balloon dilatation (DIRECTAVI) trial is a randomized controlled open label trial that include 240 patients randomized to TAVI performed with prior balloon dilatation of the valve (control arm) or direct implantation of the valve (test arm). The trial tests the hypothesis that the strategy of direct implantation of the balloon expandable SAPIEN 3 prosthesis is non-inferior to current medical practice using predilatation of the valve. The primary endpoint is related to immediate procedural success criteria and secondary end points include complications at 30-day follow-up (VARC 2 criteria). A subgroup analysis evaluates neurological ischemic events with cerebral MRI imaging (25 patients in each strategy group) performed before and after the procedure. In conclusion, we hope that the study will provide robust evidence of safety and efficiency of TAVI performed without prior dilatation of the aortic valve using the balloon expandable SAPIEN 3 THV and will allow the interventional cardiologist to use this strategy in everyday practice. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02729519
Study type Interventional
Source University Hospital, Montpellier
Contact
Status Completed
Phase N/A
Start date June 8, 2016
Completion date August 9, 2018

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease