Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT02163850
Other study ID # IP 011, G120160
Secondary ID
Status Recruiting
Phase N/A
First received June 10, 2014
Last updated April 29, 2016
Start date June 2015
Est. completion date December 2021

Study information

Verified date April 2016
Source Direct Flow Medical, Inc.
Contact Mary Edwards
Phone 707-576-0420
Email medwards@directflowmedical.com
Is FDA regulated No
Health authority United States: Food and Drug Administration
Study type Interventional

Clinical Trial Summary

Prospective, randomized, unblinded, multi-center investigational study with enrollment at up to 45 investigational sites. The study is designed to compare the study device (Direct Flow Medical Transcatheter Aortic Valve System) composite event rate to a blended commercial comparator (using approved Medtronic self-expanding bioprosthesis or Edwards balloon-expandable bioprosthesis) in high and extreme risk Subjects with severe symptomatic aortic stenosis. Subjects will be followed through the index procedure, hospital discharge, and at 30 days, 6 months and 1 year for the primary endpoint analysis. Thereafter, annual follow-up at 2 through 5 years will be conducted and analyzed separately.


Description:

Prospective, randomized, unblinded, multi-center investigational study with enrollment at up to 45 investigational sites. The study is designed to compare the study device (Direct Flow Medical Transcatheter Aortic Valve System) composite event rate to a blended commercial comparator (using approved Medtronic self-expanding bioprosthesis or Edwards balloon-expandable bioprosthesis) in high and extreme risk Subjects with severe symptomatic aortic stenosis. Subjects will be followed through the index procedure, hospital discharge, and at 30 days, 6 months and 1 year for the primary endpoint analysis. Thereafter, annual follow-up at 2 through 5 years will be conducted and analyzed separately.

The primary study endpoint is a composite of all-cause mortality, disabling stroke, or moderate or greater residual aortic regurgitation (based on core lab assessment) at 1 year. All primary endpoint events will be evaluated by a CEC using the definitions located in this protocol.

A sample size of 648 subjects (432 subjects in Direct Flow Medical Transcatheter Aortic Valve System cohort + 216 subjects in blended control cohort) will provide at least 85% power to test that the study device is non-inferior to the comparator with non-inferiority margin of 10%.

Subjects must meet the fundamental enrollment criteria of severe symptomatic, calcific aortic stenosis with quantifiable and documented source records.


Recruitment information / eligibility

Status Recruiting
Enrollment 878
Est. completion date December 2021
Est. primary completion date December 2017
Accepts healthy volunteers No
Gender Both
Age group N/A and older
Eligibility Inclusion criteria:

1. The subject has severe senile degenerative aortic valve stenosis determined by echocardiogram and Doppler, or simultaneous pressure recordings at cardiac catheterization defined as: mean aortic gradient =40 mmHg, or an aortic valve area =1.0 cm2 or aortic valve area index =0.6 cm2/m2.

2. The subject has moderate to severe symptoms from aortic valve stenosis (NYHA Functional Class =II).

3. Subject has a documented aortic annulus size of =22 mm and <29 mm based on the center's assessment of pre-procedure diagnostic imaging (and confirmed by the Patient Review Committee [PRC]) and is deemed treatable with an available size of both test and control device.

4. There is agreement by the heart team (which must include a site cardiac interventionalist and two cardiac surgeons which can be either two cardiac surgeon staff members at the hospital where the procedure is to be performed or one surgeon from the hospital where the procedure is to be performed and a surgeon from the referring institution or practice) that subject is at high operative risk or greater of serious morbidity or mortality with surgical valve replacement (see note below for definitions of extreme and high risk, the required level of surgical assessment, and PRC confirmation) and that TAVR is appropriate. Subjects will be designated either extreme risk (defined as a mortality or irreversible morbidity 50% or great at 30 days) or high risk (i.e., Society of Thoracic Surgeons operative risk score >8% or at a > 15% risk of surgical mortality at 30 days but not extreme risk). This conclusion shall be based on consensus of one cardiac interventionalist and two cardiac surgeons that have reviewed the case after careful consideration of the Subject's STS risk score and co-morbidities.

5. Subject understands the study requirements and the treatment procedures, and provides written informed consent.

6. Subject agrees and is capable of returning to the study hospital for all required scheduled follow up visits.

Exclusion criteria:

1. Left ventricular ejection fraction (LVEF) <20% determined by resting echocardiogram.

2. Subjects with an acute STEMI within 30 days preceding the index procedure.

3. Chronic kidney disease with creatinine clearance < 20 ml/min.

4. Subjects with a platelet count of <50,000 cells/mm³ or a WBC < 1000 cells/mm³ within 7 days prior to index procedure.

5. Subject has a known contraindication or hypersensitivity to all antithrombin regimens (aspirin, all P2Y12 inhibitors) that cannot be adequately pretreated, or inability to be anti-coagulated for the study procedure. Note: Subjects who require chronic anticoagulation must be able to be treated additionally with either aspirin or clopidogrel.

6. Any subject with a balloon valvuloplasty (BAV) within 72 hours prior to the index procedure.

7. Subjects who are on a waiting list for any organ transplant.

8. Subjects with known other medical illness associated with a life expectancy of less than one year, or expectation that subject will not improve despite treatment of aortic stenosis.

9. Subject has known hypersensitivity to contrast agents that cannot be adequately pre-medicated, or has known hypersensitivity to nickel, tantalum, titanium, or polyurethanes.

10. Subjects with a history of a stroke or transient ischemic attack (TIA) within previous 60 days of index procedure.

11. Subjects with an active gastrointestinal (GI) bleed or bleeding precluding dual antiplatelet therapy.

12. Subjects presenting with hemodynamic instability or cardiogenic shock requiring inotropic support or mechanical support devices.

13. Subjects who have a planned treatment with any other investigational device or procedure through 1 year follow-up, or who are currently participating in an investigational drug or another device trial.

14. Any planned surgical, percutaneous coronary or peripheral procedure to be performed within the 30 day follow-up from the TAVR procedure.

15. Untreated clinically significant coronary artery disease requiring revascularization.

16. Newly identified left atrial thrombus that has not been treated.

17. Active endocarditis or sepsis within 6 months prior to the study procedure.

18. Any condition resulting in inability to provide informed consent for the trial or difficulty in assessment of neurologic status.

19. Congenital bicuspid or unicuspid valve.

20. Prior aortic valve surgery or pre-existing prosthetic heart valve in any position (mitral and tricuspid rings are permissible).

21. A native valve annulus diameter <22mm or >29mm determined by the screening CT scan.

22. Echocardiographic evidence of new intra-cardiac mass, untreated thrombus, or vegetation that requires treatment.

23. >3+: aortic regurgitation, mitral regurgitation or tricuspid regurgitation.

24. Severe mitral or tricuspid stenosis.

25. Thoracic aortic aneurysm (TAA) >5.50 cm.

26. Inability to transfuse blood.

27. Subject has femoral arterial access that is not acceptable for the study as defined in the device Instructions for Use.

28. Coronary anatomy that precludes the perfusion of native coronary arteries post-implant.

29. Prohibitive left ventricular outflow tract (LVOT) calcification that would prevent proper deployment of a transcatheter valve.

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
Direct Flow Medical
Direct Flow Medical Transcatheter Aortic Valve Replacement System (TAVR)
Commercially Available
Medtronic CoreValve Transcatheter Aortic Valve Replacement System (TAVR) or Edwards SAPIEN Transcatheter Aortic Valve Replacement System (TAVR)

Locations

Country Name City State
United States University of Virginia Health System Charlottesville Virginia
United States Ohio Health Riverside Methodist Columbus Ohio
United States NewYork-Presbyterian / Columbia Univ. New York New York

Sponsors (1)

Lead Sponsor Collaborator
Direct Flow Medical, Inc.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Death (all cause) and disabling stroke. The primary study endpoint is a composite of all-cause mortality, disabling stroke, or moderate or greater residual aortic regurgitation (based on core lab assessment) at 1 year. 12 Months Yes
See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease