Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01445171
Other study ID # 2009-01
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 2010
Est. completion date December 2017

Study information

Verified date August 2023
Source Edwards Lifesciences
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this clinical investigation is to confirm that the safety and performance of the EDWARDS INTUITY Valve System.


Description:

This is a two-phase, non-randomized, prospective, single arm, multi-center clinical investigation. Each subject in Phase 1 and Phase 2 is consented for a period of 5 years. All subjects will be assessed for clinical follow-up at the following intervals: Discharge, 1 month, 3 months, 1 year and annually thereafter until 5 years of follow-up is achieved per subject.


Recruitment information / eligibility

Status Completed
Enrollment 295
Est. completion date December 2017
Est. primary completion date December 2017
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Criteria: Inclusion Criteria: - 18 years or older - Aortic stenosis or stenosis-insufficiency of aortic valve requiring a planned replacement as indicated in the preoperative evaluation; - Scheduled to undergo planned aortic valve replacement with or without concomitant coronary bypass surgery, MAZE procedure, septal myectomy, pacemaker/ICD implant and or atrial appendage occlusion/removal. - Signed and dated the informed consent form prior to investigation procedures; - Geographically stable and agrees to attend Follow up assessments at the hospital of surgical services for a maximum of 5 years. Exclusion Criteria: - Pure aortic insufficiency - Requires emergency surgery - Aneurysm of the aortic root and/or ascending aorta requiring surgical intervention - Left ventricular ejection fraction of = 25% - Active endocarditis within 3 months prior to the scheduled aortic valve replacement surgery - Concomitant valve (mitral, tricuspid, or pulmonic) disease requiring repair with an annuloplasty ring or replacement with prosthesis - Prior mitral, tricuspid or pulmonic valve surgery, which included implantation of a bioprosthetic valve, mechanical valve, or annuloplasty ring. - Myocardial infarction (MI) within 1 month prior to the scheduled aortic valve replacement surgery - Previously implanted with EDWARDS INTUITY Aortic valve; alcohol or drug abuser - Disease limiting life expectancy to less than 12 months - Pregnant or lactating - Currently participating in another drug or device clinical investigation; - Documented blood diatheses - Requires non-cardiac procedures such as carotid procedures or mediastinal tumor removal - Had a stroke or transient ischemic attack (TIA) within 6-months prior to scheduled aortic valve replacement surgery - Study site pre-operative echocardiographic assessment shows evidence of an intracardiac mass, thrombus, or vegetation - Hemodynamic or respiratory instability requiring inotropic support, mechanical circulatory support, or mechanical ventilation within 30 days of procedure - Documented renal insufficiency as determined by Serum creatinine = 200 µmol/L (2.27 mg/dL) at screening or end-stage renal disease requiring chronic dialysis - Documented hyperparathyroidism

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Aortic Valve Replacement with EDWARDS INTUITY Valve System
Aortic Valve bioprosthesis

Locations

Country Name City State
Austria AKH Vienna-Allgemeines Krankenhaus der Stadt Wien; University Vienna Vienna
Germany Kerchoff Klinik-Bad Nauheim Bad Nauheim
Germany MHH-Medizinische Hoschschule Hannover Hannover
Germany Herzzentrum Uniklink Koln-Klinik und Poliklinik fur Herz und Thoraxzchirurgie Koeln
Germany University Leipzig: Herzzentrum Leipzig Gmbh Leipzig
Germany Klinikum der Universitat Muchen-Grosshadern; Clinic at the University of Munich Munich

Sponsors (1)

Lead Sponsor Collaborator
Edwards Lifesciences

Countries where clinical trial is conducted

Austria,  Germany, 

References & Publications (4)

Haverich A, Wahlers TC, Borger MA, Shrestha M, Kocher AA, Walther T, Roth M, Misfeld M, Mohr FW, Kempfert J, Dohmen PM, Schmitz C, Rahmanian P, Wiedemann D, Duhay FG, Laufer G. Three-year hemodynamic performance, left ventricular mass regression, and pros — View Citation

Kocher AA, Laufer G, Haverich A, Shrestha M, Walther T, Misfeld M, Kempfert J, Gillam L, Schmitz C, Wahlers TC, Wippermann J, Mohr FW, Roth M, Skwara A, Rahmanian P, Wiedemann D, Borger MA. One-year outcomes of the Surgical Treatment of Aortic Stenosis Wi — View Citation

Laufer G, Haverich A, Andreas M, Mohr FW, Walther T, Shrestha M, Rahmanian P, Holzhey D, Roth M, Schmitz C, Schramm R, Giot C, Wahlers TCW. Long-term outcomes of a rapid deployment aortic valve: data up to 5 years. Eur J Cardiothorac Surg. 2017 Aug 1;52(2 — View Citation

Wahlers TCW, Andreas M, Rahmanian P, Candolfi P, Zemanova B, Giot C, Ferrari E, Laufer G. Outcomes of a Rapid Deployment Aortic Valve Versus Its Conventional Counterpart: A Propensity-Matched Analysis. Innovations (Phila). 2018 May/Jun;13(3):177-183. doi: — View Citation

Outcome

Type Measure Description Time frame Safety issue
Other Number of Subject's With Device Technical Success Device technical success is defined as the successful delivery and deployment of one bioprosthesis with one delivery system with a maximum of two attempts. At time of surgery, an average of 3 hours
Other Number of Subject's With Procedural Success Procedure success is defined as device technical success followed by the absence of adverse events requiring device reoperation, requiring implantation of permanent pacemaker, or subject death. Discharge(an average of 13 days) or 10 days post-implant, whichever comes first
Other Subject's New York Heart Association (NYHA) Functional Class Compared to Baseline The New York Heart Association (NYHA) functional classification system relates symptoms to everyday activities and the patient's quality of life.
Class I. No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, dyspnea (shortness of breath).
Class II. Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, dyspnea (shortness of breath).
Class III. Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, or dyspnea.
Class IV. Unable to carry on any physical activity without discomfort. Symptoms of heart failure at rest. If any physical activity is undertaken, discomfort increases.
1 Month, 3 Months, 1 Year, 2 Years, 3 Years, 4 Years, and 5 Years post-implant
Other Subject's Average Score on the EQ-5D- Quality of Life Questionnaire Over Time The EQ-5D is a standardized questionnaire that asks subjects to rate themselves (no problems, some problems, extreme problems) on mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. The scale is indexed and ranges from a minimum of 0.275 and a maximum of 1.000. A lower number indicates the participants experiences more problems and a higher number indicates the participants experiences fewer problems. Baseline, 3 Months, and 1 Year post-implant
Other Subject's Average Mean Systolic Gradient Measurements Over Time. Mean gradient is the average flow of blood through the aortic valve measured in millimeters of mercury. Gradients are evaluated by echocardiography over time. Mean gradient values depend on the size and type of valve. Discharge (an average of 13 days), 1 Month, 3 Months, 1 Year, 2 Years, 3 Years, 4 Years, and 5 Years post-implant
Other Subject's Average Effective Orifice Area Measurements Over Time. Effective orifice area represents the cross-sectional area of the blood flow downstream of the aortic valve. Effective orifice area is evaluated by echocardiography over time. Discharge (an average of 13 days), 1 Month, 3 Months, 1 Year, 2 Years, 3 Years, 4 Years, and 5 Years post-implant
Other Subject's Amount of Aortic Valvular Regurgitation Over Time Aortic valvular regurgitation occurs when the aortic valve in the heart does not close tightly allowing some of the blood that was pumped out of the heart to leak back into it. Aortic valvular regurgitation is evaluated by echocardiography over time. It is assessed on a scale from 0 to 4, where 0 represents no regurgitation and 4 represents severe regurgitation. Discharge (an average of 13 days), 1 Month, 3 Months, 1 Year, 2 Years, 3 Years, 4 Years, and 5 Years post-implant
Other Subject's Average White Blood Cell Count Measurement Over Time. Laboratory analysis of White Blood Cell Count on blood drawn from subject; WBC fight infection. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Red Blood Cells Count Over Time. Laboratory Analysis of Red Blood Cell Count on blood drawn from subjects; RBC carry oxygen. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Hemoglobin Count Over Time. Laboratory Analysis of Hemoglobin Count on blood drawn from subjects. Hemoglobin is an oxygen-carrying protein in red blood cells. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Hematocrit Percentage Over Time. Laboratory Analysis of Hematocrit Percentage on blood drawn from subjects. Hematocrit is the proportion of red blood cells to the fluid component (plasma) in the blood. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Platelet Count Over Time. Laboratory Analysis of Platelet Count on blood drawn from subjects; platelets help with blood clotting. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Reticulocytes Percentage Over Time. Reticulocytes are immature red blood cells; a reticulocyte blood test measures the amount of these cells in the blood. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Haptoglobin Measurement Over Time. Laboratory Analysis of Haptoglobin on blood drawn from subjects; Haptoglobin is a protein produced by the liver. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Other Subject's Average Serum LDH Measurement Over Time. The lactate dehydrogenase (LDH) test looks for signs of damage to the body's tissues. Baseline, 3 Months, 1 Year, and 5 Years post-implant
Primary Percent of Early Adverse Events Number of early adverse events occurring within 30 days of procedure divided by the total number of enrolled subjects times 100. Events occuring within 30 days of procedure
Primary Percent of Late Adverse Events Number of late adverse events divided by the total number of late patient years times 100. Late patient years are calculated from 31 days post-implant to the date of the last contact (follow up or adverse event). Events occurring >= 31 days and up through 5 years post-implant
See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease