Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01051518
Other study ID # COR-2006-02
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date May 2006
Est. completion date June 2013

Study information

Verified date February 2019
Source Medtronic Cardiovascular
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The investigation concerns a prospective, multicenter, single arm safety and performance study evaluating the Medtronic CoreValve system. Approximately 120 patients presenting with symptomatic aortic native valve stenosis necessitating valve replacement which are considered poor surgical candidates, with a high surgical risk, as attested to by both the surgeon and the cardiologist are recruited in the study.

Safety and performance will be evaluated at discharge and at 30 days post-procedure. Valve performance and placement will be followed up at 3 and 6 months post-procedure. Further long-term patient follow-up visits will be performed at 12, 24, 36 and 48 months post-procedure.


Recruitment information / eligibility

Status Completed
Enrollment 126
Est. completion date June 2013
Est. primary completion date February 2009
Accepts healthy volunteers No
Gender All
Age group 75 Years and older
Eligibility Inclusion Criteria:

- Native aortic valve disease, defined as valve stenosis with an aortic valve area <1cm² (<0.6cm2/m2) as determined by echocardiographic measure,

- = 75 years, or

- Surgical risk calculated with logistic EuroSCORE = 15 %, or

- One or two (but not more than 2) of the following complicating factors:

1. Cirrhosis of the liver (Child class A or B),

2. Pulmonary insufficiency : Forced expiratory volume in one second (FEV1) < 1 liter,

3. Previous cardiac surgery (Coronary artery bypass grafting (CABG), valvular surgery),

4. Pulmonary hypertension > 60 mmHg and high risk of cardiac surgery other than valve replacement,

5. Porcelain aorta

6. Recurrent pulmonary embolus,

7. Right ventricular insufficiency,

8. Thoracic burning sequelae contraindicating open chest surgery,

9. History of mediastinum radiotherapy,

10. Severe connective tissue disease resulting in a contraindication to surgery,

11. Cachexia (BMI = 18 kg/m²),

- Aortic valve annulus diameter is = 20 mm and = 27 mm as determined by echocardiographic measure,

- Ascending aorta diameter £ 45 mm at the sino-tubular junction, and

- Signed Informed Consent.

Exclusion Criteria:

- Known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated,

- Any sepsis, including active endocarditis,

- Recent myocardial infarction (< 30 days),

- Percutaneous coronary or vascular intervention within 15 days prior to the study procedure, or scheduled during or within 30 days after the study procedure,

- Any left ventricular or atrial thrombus diagnosed by echocardiography,

- Uncontrolled atrial fibrillation (heart rate greater than 100 bpm),

- Mitral or tricuspid valvular insufficiency ( > grade II),

- Previous aortic valve replacement (mechanical valve OR stented bioprosthetic valve),

- Any condition considered as contraindication for extracorporeal assistance,

- Evolutive or recent CVA (cerebro vascular accident),

- Poly arterial patients with either:

1. Femoral, iliac or aortic vascular condition (e.g. stenosis, tortuosity), that make insertion and endovascular access to the aortic valve impossible, or

2. Symptomatic carotid or vertebral arteries narrowing (> 70%) disease, or

3. Abdominal or thoracic aortic aneurysm,

- Bleeding diathesis or coagulopathy, or patient who will refuse blood transfusion,

- Evolutive disease with life expectancy less than one year,

- Creatinine clearance < 20 ml/min,

- Pregnancy, and

- Enrolled in another investigational study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Medtronic CoreValve System
Transcatheter Aortic Valve

Locations

Country Name City State
Canada University of Alberta Hospital Edmonton
Canada Institut de Cardiologie de Montreal Montreal
Canada University of Ottawa Heart Institute Ottawa
Germany Herzzentrum Leipzig GmbH Leipzig
Germany HELIOS Heart Center Siegburg Siegburg
Netherlands Amphia Hospital Breda
Netherlands Erasmus MC Rotterdam
United Kingdom Glenfield Hospital Leicester
United Kingdom Royal Brompton & Harefield NHS Trust London

Sponsors (1)

Lead Sponsor Collaborator
Medtronic Bakken Research Center

Countries where clinical trial is conducted

Canada,  Germany,  Netherlands,  United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Composite Major Adverse Event (MAE) Free Rate Percentage of subjects without a composite major adverse event (MAE) at 30 (+ 7) days post-procedure. MAE included all-cause death, non-fatal myocardial infarction, stroke, emergent cardiac re-intervention, cardiac tamponade, non-structural or structural valve dysfunction, cardiogenic shock, endocarditis, TIA, embolism, aortic dissection, access site vessel dissection, vessel perforation, acute vessel occlusion, major bleeding and major vascular injury. 30 (+7) days post procedure
Secondary Composite Technical Device Success Composite technical success was defined as the percentage of subjects in whom success on all four technical measures of the "Device Functionality Assessment" was achieved and who were adjudicated as having no device failure or malfunction.
The four measures of the ''Device Functionality Assessment'' were:
Load the valve delivery system using the loading system
Access the aortic valve with the delivery catheter
Deploy the valve accurately across the native aortic valve
Remove the intact delivery system
Was assessed during the procedure and completed once the procedure was conlcluded
See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease

External Links