Clinical Trials Logo

Clinical Trial Summary

The objective of this study is to investigate safety and performance of the Free Margin Cusp sizer. The device will be used during aortic valve repair and sparing procedures as a caliper to measure the aortic valve free margin length at different stages of the procedure. The patient will be followed for one year clinically (at 1, 2, 6 and 12 months) and by echocardiography (at 6 and 12 months) to assess aortic valve function.


Clinical Trial Description

Goal of the study : The objective of this study is to study the safety and reliability of a new surgical instrument, the "Free Margin Cusp Sizer" (patented device). The measuring instrument will be used during aortic valve repair procedures to measure the length of the free edge of the aortic cusps. State of the art : Currently, aortic valve repair is done by visual estimation and requires a great level of experience from the surgeon. We proposed to develop an objective cusp repair technique based on the measurement of the free edge by a dedicated sizer. The measuring instrument will give the objective difference in millimeters between the normal cusp and the one with prolapse. This will then be quantitatively plicatured to correct its excess length. This new technique will allow less experienced surgeons or those in the process of learning objective guidance of valve repair. The objective measure of the free edge length may also orient the sizing of the Dacron graft used for valve sparing root replacement. Study evaluation criteria: - Hospital mortality (mortality at 30 days), MACCE at one year: mortality, cerebrovascular accident or transient ischemic attack, major hemorrhage, cardiac reoperation - Echocardiographic results at discharge from hospital and at 6 months or one year Material and methods: - Single-center, prospective, non-randomized study - Patient source: Patients operated for aortic valve repair or aortic valve sparing surgery at Cliniques Universitaires Saint-Luc (CUSL), Brussels - Number of patients to be included: 80, study duration: 4 years, inclusion period: 3 years, follow-up: 1 year - Inclusion criteria: patient with a tricuspid aortic valve operated electively for aortic valve insufficiency or dilation of the ascending aorta - Exclusion criteria: acute aortic dissection, diffuse aortic valve calcification, endocarditis, bicuspide, unicuspid or quadricuspid aortic valve, patient under 18 and over 80 Data acquisition and patient follow-up: The examinations carried out within the framework of this study are the same as those carried out routinely during the preoperative cardiac assessment and clinical follow-up after aortic valve repair: - Preoperative cardiovascular examination including TTE (transthoracic ultrasound) / TEE (transesophageal ultrasound) - Intraoperative TEE pre and post aortic valve repair - TTE at discharge - TTE between 6 months and one year postoperatively - 1 month post-operative consultation (outpatient surgery) - Consultation 1 to 2 months postoperative (referring cardiologist) - Consultation 6-12 months postoperative (referring cardiologist) (if necessary, phone contact with the patient at 12-14 months) ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04797572
Study type Interventional
Source Cliniques universitaires Saint-Luc- Université Catholique de Louvain
Contact Laurent de Kerchove, MD, PhD
Phone +32 2 764 41 51
Email laurent.dekerchove@uclouvain.be
Status Recruiting
Phase N/A
Start date March 22, 2021
Completion date January 1, 2025

See also
  Status Clinical Trial Phase
Recruiting NCT05438862 - Early Aortic vaLve surgEry Versus wAtchful waitiNg Strategy in Severe Asymptomatic aOrtic reguRgitation N/A
Completed NCT03644784 - Protocoled Quantitative Assessment of Aortic Regurgitation Using Videodensitometry in a Multicontinental Trial in Rotterdam, Montreal, Yamaguchi, Segeberg, Amsterdam.
Recruiting NCT06381271 - Transcatheter Aortic Valve Replacement for Pure Severe Aortic Valve Regurgitation
Not yet recruiting NCT05536310 - TAVIS Registry - Trilogy Heart Valve System for Management of Patients With Aortic Valve Disease
Completed NCT02375282 - Physical and Functional Recovery From Cardiac Surgery in Hospitalized Patients: A Feasibility Pilot Study N/A
Completed NCT04548726 - Hemodynamic Matched Comparison of the Balloon-Expandable Transcatheter Heart Valves Myval and Sapien-3 for the Treatment of Aortic Stenosis
Not yet recruiting NCT06455787 - J-Valve Transfemoral Pivotal Study N/A
Completed NCT01593917 - Trifectaâ„¢ Long Term Follow-Up (LTFU) Study
Recruiting NCT05459233 - Valve Hemodynamic Optimization Based on Doppler-Echocardiography vs Catheterization Measurements Following ViV TAVR N/A
Recruiting NCT05902897 - Aortic or Mitral Valve Replacement With the Braile Biomédica® Bovine Pericardium Valvular Bioprosthesis
Completed NCT03807921 - Anticoagulation for Aortic Bioprosthesis (ANTIPRO) Phase 4
Recruiting NCT04464655 - A 10-Minute Cardiovascular Magnetic Resonance Protocol for Cardiac Disease
Recruiting NCT05799573 - CT Scan Sizing for Perceval Sutureless Valve
Completed NCT00636987 - Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra N/A