Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT02201589
Other study ID # PSIDE:Ascending Thoracic Aorta
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date September 2013
Est. completion date December 2030

Study information

Verified date December 2023
Source Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center
Contact Rodney A White, M.D.
Phone 310 222-2704
Email rawhite@ucla.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to investigate the outcome of patients with pathologies of the ascending thoracic aorta (diseases in the great blood vessel or artery that leads away from the heart) including type A aortic dissection, retrograde type A aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm who are suitable for endovascular (within the vessel) repair with the Medtronic Valiant PS-IDE (Physician Sponsored-Investigational Device Exemption) Stent Graft. Type A aortic dissection is a condition where blood passes through the inner lining or between the layers of the blood vessel from a tear in the aortic wall (dissection) in the ascending aorta; a retrograde Type A aortic dissection is a condition where the dissection or tear in the ascending aorta starts from the descending aorta; an intramural hematoma is a collection of clotted blood within the aortic wall; a penetrating ulcer has a plaque or clot within the wall and a pseudoaneurysm is a false aneurysm . If left untreated in any of these conditions, the aorta can enlarge and rupture causing injury or death. The plan for these patients is to repair the ascending thoracic aorta using the Medtronic Valiant PS-IDE Stent Graft with the Captivia Delivery System. The Valiant Captivia has been evaluated worldwide and used extensively in patients with type B (descending) thoracic aortic dissection. Since the dissections in the ascending aortas mirror that of the descending aorta, it is expected that this stent graft will deliver similar performance and endurance in patients with type A aortic dissection. The investigators expect to reroute the blood to the true lumen (the inner space within the blood vessel) by covering the proximal (nearest to the heart) tear with the stent graft. The stent graft is a stent frame made from Nitinol wire and covered with an expandable material made of a polyester material. This new study will determine how well the device works to treat dissections, intramural hematomas, penetrating ulcers and pseudoaneurysms in the ascending thoracic aorta.


Description:

This is a prospective study with 20 patients planned to be enrolled. Patients who participate will be followed for 5 years after the surgery in which the stent graft was implanted. This will include the following schedule: A CT with and without contrast and echocardiogram 30 days after the Medtronic device is implanted, CT with and without contrast at 6 and 12 months post procedure and once a year from 2 years thru 5 years after the implant.


Recruitment information / eligibility

Status Recruiting
Enrollment 20
Est. completion date December 2030
Est. primary completion date December 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Patient must have a Type A thoracic aortic dissection, retrograde Type A thoracic aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm of the ascending thoracic aorta affecting the area between the Sinus of Valsalva and the innominate artery orifice (with no involvement of the aortic valve) and be considered candidates for endovascular repair; - Patient must also have at least one cm proximal and distal landing zones in the ascending aorta between 28-44 mm in diameter; - The patient must be deemed high-risk surgical candidate according to the following established criteria: ASA (American Society of Anesthesiologists) class IV. Exclusion Criteria: - Pregnant or pediatric patients (younger than 21 years of age); - Patients who have a condition that threatens to infect the stent graft/aortic valve prosthesis; - Patients with allergies to the stent graft material; - Patients or their legally authorized representatives who do not sign the informed consent; - Patients with expected survival less than one year.

Study Design


Intervention

Device:
Endovascular repair with Valiant PS-IDE Stent Graft
Endovascular stent graft repair of lesions in the ascending thoracic aorta using the Medtronic Valiant PS-IDE (Physician Sponsored-Investigational Device Exemption) Stent Graft System with the Captivia Delivery System

Locations

Country Name City State
United States Long Beach Memorial Medical Center Long Beach California
United States Cedars Sinai Medical Center Los Angeles California
United States LAC Harbor-UCLA Medical Center Torrance California

Sponsors (1)

Lead Sponsor Collaborator
Rodney A. White, M.D.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Composite of all cause mortality, re-interventions, surgical conversions, post-procedural strokes and ischemic or hemorrhagic events causing motoric, language or cognitive compromise Mortality, re-interventions, surgical conversions and post-procedure adverse events Within 30 days of the index procedure
Secondary A composite of successful delivery and deployment of stent graft, coverage of lesion and/or proximal entry tear, aortic remodeling based on serial imaging, rupture Successful deployment covering the entry tear, remodeling of lesion determined by serial CT scans and documentation of ruptures To 30 days
See also
  Status Clinical Trial Phase
Completed NCT05582967 - The DAShED (Diagnosis of Aortic Syndrome in the ED) Study
Terminated NCT04116684 - Digital Home Blood Pressure Monitoring in Type B Aortic Dissection Patients N/A
Completed NCT02086136 - Aortic Dissection Detection Risk Score Plus D-dimer in Suspected Acute Aortic Dissection
Recruiting NCT03948555 - Magnetic Resonance Imaging (MRI) for Aortic Dissection to Visualise Inflammation
Enrolling by invitation NCT05912608 - Optimal Strategy for Repair of Type A Acute Aortic Dissection
Recruiting NCT03707743 - Registry of Patients With Acute/Subacute Type B Aortic Dissection Treated by Means of the STABILISE Technique (STABILISE)
Enrolling by invitation NCT00583817 - Endovascular Treatment of Thoracic Aortic Disease N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT02523300 - Glucocorticoid on the Prognosis of TEVAR N/A
Completed NCT01197651 - Aortic-Stent-Register N/A
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Not yet recruiting NCT06044259 - Study Comparing Hemiarch Replacement and Hemiarch Plus Stent Implantation in Acute Aortic Dissection N/A
Completed NCT05039814 - Prediction of Postoperative Acute Kidney Injury in Patients With Acute Type A Aortic Dissection Using Cystatin C
Recruiting NCT03780738 - A Validation Study of The Relationship Between ALDH2 and Aortic Dissection
Completed NCT03647566 - 18F Sodium Fluoride PET/CT in Acute Aortic Syndrome
Enrolling by invitation NCT05800743 - Evaluation of the GORE® Ascending Stent Graft N/A
Recruiting NCT03347812 - Clinical Study for Evaluating the Safety and Efficacy of Total Endovascular Aortic Arch Repair N/A
Completed NCT05044494 - Surgery for Delay-recognized or Defer-operated Type A Aortic Dissection
Terminated NCT02958098 - My Research Legacy Pilot Study
Recruiting NCT04450433 - Functional Study of Metabolites in Patients With Aortic Dissection