Aortic Aneurysm Clinical Trial
Official title:
The Value of Dynamic CTA During the Follow-up of EndoVascular Aortic Replacement (EVAR): a Pilot Study
This pilot study aims to quantitatively characterize the stresses and forces on an implanted endograft during the cardiac cycle in patients scheduled for standard endograft follow-up. The developed techniques will be applied in future studies for characterizing and comparing the currently commercially available endografts so as to gain insight into the mechanisms underlying potential endograft failure. In addition, to assist in developing endografts with long-term durability and functioning characteristics for the benefit of the patient
Endovascular Aortic replacement (EVAR) for the treatment of aortic aneurysms in patients at
risk of aneurysm rupture is an established endovascular technique (ref: Blankensteijn, NEJM,
2005). However, the development of the endograft design is ongoing in order to prevent late
endograft failure (e.g. graft breakage, graft displacement). The stresses and forces applied
to the endograft by the high physiological forces and stresses in the aorta have an effect
on the durability and functioning of the endograft. The stresses and forces that occur
during movement may be reflected by movement of the endograft itself during the cardiac
cycle. Standard patient follow-up involves transverse CT imaging to detect endograft
leakage. However, transverse imaging does not provide information on endograft displacement
but does provide information on shrinkage of the aneurysm after endograft placement.
Therefore, additional information on the longitudinal displacement of the endograft during
the cardiac cycle may assist in determining the optimal characteristics of a durable
endograft and therefore benefit the patient in the long-term. Evaluation of the stresses and
forces by calculating longitudinal displacement of the endograft appears possible by
applying a cardiac CT technique, namely, dynamic CTA (computed tomography angiography), on
an endovascular device. To our knowledge, this new approach will yield new in vivo data on
endograft behavior.
This pilot study aims to quantitatively characterize the stresses and forces on an implanted
endograft during the cardiac cycle in patients scheduled for standard endograft follow-up.
In addition, in order to have the possibility to compare the movement of the aorta pre- and
post-endograft placement, the aorta of patients planned for an endograft implantation
procedure and who are thus already planned to undergo a clinical CT will also instead be
scanned using ECG gated dynamic CTprotocol.
The developed techniques will be applied in future studies for characterizing and comparing
the currently commercially available endografts so as to gain insight into the mechanisms
underlying potential endograft failure, and in addition, to assist in developing endografts
with long-term durability and functioning characteristics for the benefit of the patient.
;
Observational Model: Cohort, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Enrolling by invitation |
NCT04035356 -
HAART Annuloplasty Device Valve Repair Registry
|
||
Recruiting |
NCT02729064 -
Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose
|
Phase 1 | |
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Completed |
NCT02283307 -
Dual Energy CT Urography With Reduced Iodinated Contrast
|
N/A | |
Completed |
NCT01678261 -
X-chromosome Inactivation, Epigenetics and the Transcriptome
|
N/A | |
Terminated |
NCT01055275 -
Cook Iliac Branch Graft Post-market Registry
|
N/A | |
Completed |
NCT00615888 -
Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair
|
N/A | |
Completed |
NCT03510793 -
Microcirculation and Anesthesia in Vascular Surgery
|
||
Completed |
NCT03207568 -
RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU)
|
N/A | |
Recruiting |
NCT05073991 -
Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
|
||
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Not yet recruiting |
NCT01918982 -
Circulating Endothelial Progenitor Cells and Aortic Aneurysm
|
N/A | |
Not yet recruiting |
NCT01918969 -
Reference Values of Circulating Endothelial Progenitor Cells
|
N/A | |
Completed |
NCT01256372 -
An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery
|
Phase 2 | |
Recruiting |
NCT00661518 -
PET/CT Imaging of Aneurysm Wall Inflammation
|
N/A | |
Completed |
NCT00094575 -
Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA)
|
Phase 4 | |
Recruiting |
NCT04471909 -
NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness
|
N/A | |
Recruiting |
NCT05603520 -
Phenotyping Heterogeneity and Regionality of the Aorta
|
||
Completed |
NCT03727542 -
Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels
|
N/A |